IEC 60507:2013

Current

Current

The latest, up-to-date edition.

Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems

Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English - French, Spanish, Castilian

Published date

13-12-2013

€244.32
Excluding VAT

FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 General test requirements
5 Salt fog method
6 Solid layer methods
Annex A (informative) - Supplementary information on the
        assessment of the requirement for the testing plant
Annex B (informative) - Determination of the withstand
        characteristics of insulators
Annex C (informative) - Measurement of layer conductivity
        for checking the uniformity of the layer
Annex D (informative) - Additional recommendations concerning
        the solid layer method procedures
Annex E (informative) - Supplementary information on artificial
        pollution tests on insulators for voltage systems of
        800 kV and above (solid layer method procedure B)
Bibliography

IEC 60507:2013 is applicable for the determination of the power frequency withstand characteristics of ceramic and glass insulators to be used outdoors and exposed to polluted atmospheres, on a.c. systems with the highest voltage of the system greater than 1 000 V. These tests are not directly applicable to polymeric insulators, to greased insulators or to special types of insulators (insulators with semiconducting glaze or covered with any organic insulating material). The object of this International Standard is to prescribe procedures for artificial pollution tests applicable to insulators for overhead lines, substations and traction lines and to bushings. It may also be applied to hollow insulators with suitable precautions to avoid internal flashover. In applying these procedures to apparatus incorporating hollow insulators, the relevant technical committees should consider their effect on any internal equipment and the special precautions which may be necessary. This edition includes the following significant technical changes with respect to the previous edition:
a) Corrections and the addition of explanatory material;
b) The addition of Clause 4.3.2 on atmospheric correction;
c) The change of the upper limit of conductivity of water to 0.1 S/m; and
d) The extension to UHV voltages.
The contents of the corrigendum of August 2018 have been included in this copy.

Committee
TC 36
DevelopmentNote
Stability date: 2019. (09/2017)
DocumentType
Standard
Pages
78
PublisherName
International Electrotechnical Committee
Status
Current
Supersedes

Standards Relationship
UNE-EN 60507:1995 Identical
NF EN 60507 : 2014 Identical
NEN EN IEC 60507 : 2014 Identical
I.S. EN 60507:2014 Identical
PN EN 60507 : 2014 Identical
SN EN 60507 : 2014 Identical
VDE 0448-1 : 2014 Identical
IS 8704 : 2018 Identical
BS EN 60507:2014 Identical
CEI EN 60507 : 2014 Identical
EN 60507:2014 Identical
UNE-EN 60507:2014 Identical
NEN 10507 : 1993 Identical
VDE 0448-100 : DRAFT 92 Identical
VDE 0448-2 : 1977 Identical
PN IEC 507 : 1998 Identical
DIN EN 60507 : 2014 Identical
NBN EN 60507 : 2014 Identical
SAC GB/T 4585 : 2004 Identical
UNE 21129:1980 Identical

UNE-EN 50124-1:2017 Railway applications - Insulation coordination - Part 1: Basic requirements - Clearances and creepage distances for all electrical and electronic equipment
CEI EN 61462 : 2008 COMPOSITE HOLLOW INSULATORS - PRESSURIZED AND UNPRESSURIZED INSULATORS FOR USE IN ELECTRICAL EQUIPMENT WITH RATED VOLTAGE GREATER THAN 1000 V - DEFINITIONS, TEST METHODS, ACCEPTANCE CRITERIA AND DESIGN RECOMMENDATIONS
CEI 36-43 : 2011 SELECTION AND DIMENSIONING OF HIGH-VOLTAGE INSULATORS INTENDED FOR USE IN POLLUTED CONDITIONS - PART 3: POLYMER INSULATORS FOR A.C. SYSTEMS
10/30210015 DC : 0 BS EN 60099-5 - SURGE ARRESTERS - SELECTION AND APPLICATION RECOMMENDATIONS
CEI EN 62231 : 2007 COMPOSITE STATION POST INSULATORS FOR SUBSTATIONS WITH A.C. VOLTAGES GREATER THAN 1000 V UP TO 245 KV - DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA
I.S. EN IEC 60099-8:2018 SURGE ARRESTERS - PART 8: METAL-OXIDE SURGE ARRESTERS WITH EXTERNAL SERIES GAP (EGLA) FOR OVERHEAD TRANSMISSION AND DISTRIBUTION LINES OF A.C. SYSTEMS ABOVE 1 KV
BS 7923:2004 Electric cables. Internal gas-pressure cables and accessories for alternating voltages up to and including 275 kV (<i>U</i><sub>m</sub> = 300 kV). Requirements and test methods
CEI EN 61952 : 2009 INSULATORS FOR OVERHEAD LINES - COMPOSITE LINE POST INSULATORS FOR A.C. SYSTEMS WITH A NOMINAL VOLTAGE GREATER THAN 1000 V - DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA
17/30339060 DC : 0 BS EN 60071-2 - INSULATION CO-ORDINATION - PART 2: APPLICATION GUIDE (PROPOSED HORIZONTAL STANDARD)
13/30286196 DC : 0 BS EN 61245 - ARTIFICIAL POLLUTION TESTS ON HIGH-VOLTAGE INSULATORS TO BE USED ON D.C SYSTEM
PD IEC/TR 62001:2009 High-voltage direct current (HVDC) systems. Guidebook to the specification and design evaluation of A.C. filters
BS EN 50123-7-3:2003 Railway applications. Fixed installations. d.c. switchgear. Measurement, control and protection devices for specific use in d.c. traction systems Isolating voltage transducers and other voltage measuring devices
HD 633 S1:1997 Tests on oil-filled (fluid filled), paper- or polypropylene paper laminate-insulated, metal-sheathed cables and accessories for alternating voltages up to and including 400 kV (Um = 420 kV)
BS EN 50152-3-3:2016 Railway applications. Fixed installations. Particular requirements for a.c. switchgear Measurement, control and protection devices for specific use in a.c. traction systems. Voltage transformers
PD IEC/TR 62730:2012 HV polymeric insulators for indoor and outdoor use tracking and erosion testing by wheel test and 5 000h test
IEEE C37.017-2010 IEEE Standard for Bushings for High-Voltage [over 1000 V (ac)] Circuit Breakers and Gas-Insulated Switchgear
I.S. HD 632:2016 POWER CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES ABOVE 36 KV (U[M] = 42 KV) UP TO 150 KV (U[M] = 170 KV)
BS 7626:1993 Specification for current transformers
11/30235280 DC : 0 BS EN 50152-1 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 1: CIRCUIT-BREAKERS WITH NOMINAL VOLTAGE ABOVE 1 KV
15/30298489 DC : 0 BS EN 50124-1 - RAILWAY APPLICATIONS - INSULATION COORDINATION - PART 1: BASIC REQUIREMENTS - CLEARANCES AND CREEPAGE DISTANCES FOR ALL ELECTRICAL AND ELECTRONIC EQUIPMENT
CAN/CSA-C156.3-M86 (R2013) Test Methods for Station Post Insulators
DD IEC/TS 60815-1:2008 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions Definitions, information and general principles
BS EN 61442:2005 Test methods for accessories for power cables with rated voltages from 6 kV (Um = 7,2 kV) up to 36 kV (Um = 42 kV)
EN IEC 60099-8:2018 Surge arresters - Part 8: Metal-oxide surge arresters with external series gap (EGLA) for overhead transmission and distribution lines of a.c. systems above 1 kV
CSA C62155 : 2006 : R2015 HOLLOW PRESSURIZED AND UNPRESSURIZED CERAMIC AND GLASS INSULATORS FOR USE IN ELECTRICAL EQUIPMENT WITH RATED VOLTAGES GREATER THAN 1000 V
CSA C156.3 : 1986 : R1999 TEST METHODS FOR STATION POST INSULATORS
PREN 50152-3-2 : DRAFT 2015 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR A.C. SWITCHGEAR - PART 3-2: MEASUREMENT, CONTROL AND PROTECTION DEVICES FOR SPECIFIC USE IN A.C. TRACTION SYSTEMS - SINGLE-PHASE CURRENT TRANSFORMERS
IEC TS 60815-2:2008 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 2: Ceramic and glass insulators for a.c. systems
I.S. EN 60694:1999 COMMON SPECIFICATIONS FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS
I.S. EN 61462:2007 COMPOSITE HOLLOW INSULATORS - PRESSURIZED AND UNPRESSURIZED INSULATORS FOR USE IN ELECTRICAL EQUIPMENT WITH RATED VOLTAGE GREATER THAN 1 000 V - DEFINITIONS, TEST METHODS, ACCEPTANCE CRITERIA AND DESIGN RECOMMENDATIONS
IEC 60099-5:2018 Surge arresters - Part 5: Selection and application recommendations
I.S. EN 50123-1:2003 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - GENERAL
I.S. EN 61442:2005 TEST METHODS FOR ACCESSORIES FOR POWER CABLES WITH RATED VOLTAGES FROM 6 KV (U[M] = 7,2 KV) UP TO 36 KV (U[M] = 42 KV)
EN 62271-1:2017 High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear
BS EN 50341-1:2012 Overhead electrical lines exceeding AC 1 kV General requirements. Common specifications
I.S. HD 634:1999 TESTS ON INTERNAL GAS-PRESSURE CABLES AND ACCESSORIES FOR ALTERNATING VOLTAGES UP TO AND INCLUDING 275 KV (UM = 300 KV)
CEI 36-41 : 2011 SELECTION AND DIMENSIONING OF HIGH-VOLTAGE INSULATORS INTENDED FOR USE IN POLLUTED CONDITIONS - PART 1: DEFINITIONS, INFORMATION AND GENERAL PRINCIPLES
BS EN 50123-7-2:2003 Railway applications. Fixed installations. d.c. switchgear. Measurement, control and protection devices for specific use in d.c. traction systems Isolating current transducers and other current measuring devices
UNE-EN 60099-4:2016 Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems
I.S. EN 50152-3-3:2016 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR A.C. SWITCHGEAR - PART 3-3: MEASUREMENT, CONTROL AND PROTECTION DEVICES FOR SPECIFIC USE IN A.C. TRACTION SYSTEMS - VOLTAGE TRANSFORMERS
EN 60137:2017 Insulated bushings for alternating voltages above 1 000 V
IEC TS 60815-1:2008 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 1: Definitions, information and general principles
IEC 62497-1:2010+AMD1:2013 CSV Railway applications - Insulation coordination - Part 1: Basic requirements - Clearances and creepage distances for all electricaland electronic equipment
IEC 60694:1996+AMD1:2000+AMD2:2001 CSV Common specifications for high-voltage switchgear and controlgear standards
EN 60099-4:2014 Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems
IEC 60099-5:2018 RLV Surge arresters - Part 5: Selection and application recommendations
EN 60694:1996/A2:2001 COMMON SPECIFICATIONS FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS
EN 62155:2003 Hollow pressurized and unpressurized ceramic and glass insulators for use in electrical equipment with rated voltages greater than 1 000 V
EN 60071-1:2006/A1:2010 INSULATION CO-ORDINATION - PART 1: DEFINITIONS, PRINCIPLES AND RULES
EN 61442:2005 Test methods for accessories for power cables with rated voltages from 6 kV (Um = 7,2 kV) up to 36 kV (Um = 42 kV)
EN 62271-201:2014 High-voltage switchgear and controlgear - Part 201: AC solid-insulation enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
HD 597 S1:1992/corrigendum:1992 COUPLING CAPACITORS AND CAPACITOR DIVIDERS
EN 50152-3-3:2016 Railway applications - Fixed installations - Particular requirements for a.c. switchgear - Part 3-3: Measurement, control and protection devices for specific use in a.c. traction systems - Voltage transformers
EN 62231:2006 Composite station post insulators for substations with a.c. voltages greater than 1 000 V up to 245 kV - Definitions, test methods and acceptance criteria
EN 62223 : 2009 INSULATORS - GLOSSARY OF TERMS AND DEFINITIONS
EN 62271-103:2011 High-voltage switchgear and controlgear - Part 103: Switches for rated voltages above 1 kV up to and including 52 kV
EN 61952:2008 Insulators for overhead lines - Composite line post insulators for A.C. systems with a nominal voltage greater than 1 000 V - Definitions, test methods and acceptance criteria
EN 50152-3-2:2016 Railway applications - Fixed installations - Particular requirements for a.c. switchgear - Part 3-2: Measurement, control and protection devices for specific use in a.c. traction systems - Current transformers
06/30126000 DC : DRAFT MAY 2006 IEC 60815-1 - SELECTION AND DIMENSIONING OF HIGH-VOLTAGE INSULATORS FOR POLLUTED CONDITIONS - PART 1: DEFINITIONS, INFORMATION AND GENERAL PRINCIPLES
BS EN 60060-1:2010 High-voltage test techniques General definitions and test requirements
06/30149569 DC : DRAFT APR 2006 IEC 60060-1 - HIGH-VOLTAGE TEST TECHNIQUES - PART 1: GENERAL DEFINITIONS AND TEST REQUIREMENTS
I.S. EN 50123-3:2003 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 3: INDOOR D.C. DISCONNECTORS, SWITCH-DISCONNECTORS AND EARTHING SWITCHES
EN 60071-2:1997 Insulation co-ordination - Part 2: Application guide
UNE-EN 50152-2:2013 Railway applications - Fixed installations - Particular requirements for alternating current switchgear - Part 2: Disconnectors, earthing switches and switches with nominal voltage above 1 kV
CEI EN 62217 : 2013 POLYMERIC HV INSULATORS FOR INDOOR AND OUTDOOR USE - GENERAL DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA
NF EN 60099-4 : 2015 SURGE ARRESTERS - PART 4: METAL-OXIDE SURGE ARRESTERS WITHOUT GAPS FOR A.C. SYSTEMS
BS EN 62155:2003 Hollow pressurized and unpressurized ceramic and glass insulators for use in electrical equipment with rated voltages greater than 1000 V
13/30294291 DC : 0 BS EN 62561-8 - LIGHTNING PROTECTION SYSTEM COMPONENTS (LPSC) - PART 8: REQUIREMENTS FOR COMPONENTS FOR ISOLATED LPS
BS EN 61462:2007 Composite hollow insulators. Pressurized and unpressurized insulators for use in electrical equipment with rated voltage greater than 1000 V. Definitions, test methods, acceptance criteria and design recommendations
05/30122919 DC : DRAFT JUN 2005
CEI EN 62155 : 2004 HOLLOW PRESSURIZED AND UNPRESSURIZED CERAMIC AND GLASS INSULATORS FOR USE IN ELECTRICAL EQUIPMENT WITH RATED VOLTAGES GREATER THAN 1000 V
09/30167595 DC : 0 BS EN 60099-8 ED.1 - SURGE ARRESTERS - PART 8: METAL-OXIDE SURGE ARRESTERS WITH EXTERNAL SERIES GAP (EGLA) FOR OVERHEAD TRANSMISSION AND DISTRIBUTION LINES OF A.C. SYSTEMS ABOVE 1 KV
DD IEC/TS 60815-2:2008 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions Ceramic and glass insulators for a.c. systems
CSA C62155:2006 HOLLOW PRESSURIZED AND UNPRESSURIZED CERAMIC AND GLASS INSULATORS FOR USE IN ELECTRICAL EQUIPMENT WITH RATED VOLTAGES GREATER THAN 1000 V
04/30111859 DC : 0 IEC 62271-1 - HIGH-VOLTAGE SWITCHGEAR AND CONTROL GEAR - PART 1: COMMON SPECIFICATIONS
PREN 50124-1 : DRAFT 2015 RAILWAY APPLICATIONS - INSULATION COORDINATION - PART 1: BASIC REQUIREMENTS - CLEARANCES AND CREEPAGE DISTANCES FOR ALL ELECTRICAL AND ELECTRONIC EQUIPMENT
CEI EN 62223 : 2010 INSULATORS - GLOSSARY OF TERMS AND DEFINITIONS
IEC TR 62001-1:2016 High-voltage direct current (HVDC) systems - Guidance to the specification and design evaluation of AC filters - Part 1: Overview
CSA C156.3 : 1986 : R2009 TEST METHODS FOR STATION POST INSULATORS
BIS IS/IEC 60071-2 : 1996(R2017) INSULATION CO-ORDINATION - PART 2: APPLICATION GUIDE
EN 50123-7-2:2003 Railway applications - Fixed installations - D.C. switchgear - Part 7-2: Measurement, control and protection devices for specific use in d.c. traction systems - Isolating current transducers and other current measuring devices
NF EN 60060-1 : 2011 HIGH-VOLTAGE TEST TECHNIQUES - PART 1: GENERAL DEFINITIONS AND TEST REQUIREMENTS
BS EN 50123-1:2003 Railway applications. Fixed installations. D.C. switchgear General
I.S. EN 50123-4:2003 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 4: OUTDOOR D.C. DISCONNECTORS, SWITCH-DISCONNECTORS AND EARTHING SWITCHES
BS EN 60137:2017 Insulated bushings for alternating voltages above 1000 V
I.S. EN 60137:2017 INSULATED BUSHINGS FOR ALTERNATING VOLTAGES ABOVE 1000 V
I.S. EN 62231:2007 COMPOSITE STATION POST INSULATORS FOR SUBSTATIONS WITH A.C. VOLTAGES GREATER THAN 1 000 V UP TO 245 KV - DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA
CEI EN 60099-5 : 2014 SURGE ARRESTERS - PART 5: SELECTION AND APPLICATION RECOMMENDATIONS
EN 50124-1:2017 Railway applications - Insulation coordination - Part 1: Basic requirements - Clearances and creepage distances for all electrical and electronic equipment
CEI 36-42 : 2011 SELECTION AND DIMENSIONING OF HIGH-VOLTAGE INSULATORS INTENDED FOR USE IN POLLUTED CONDITIONS - PART 2: CERAMIC AND GLASS INSULATORS FOR A.C. SYSTEMS
CEI EN 62271-201 : 2015 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 201: AC SOLID-INSULATION ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV
BS 5463:1977 Specification for a.c. switches of rated voltage above 1 kV
I.S. EN 62223:2009 INSULATORS - GLOSSARY OF TERMS AND DEFINITIONS
IEC 60099-8:2017 Surge arresters - Part 8: Metal-oxide surge arresters with external series gap (EGLA) for overhead transmission and distribution lines of a.c. systems above 1 kV
CEI EN 60099-4 : 2015 SURGE ARRESTERS - PART 4: METAL-OXIDE SURGE ARRESTERS WITHOUT GAPS FOR A.C. SYSTEMS
EN 50341-1:2012 Overhead electrical lines exceeding AC 1 kV - Part 1: General requirements - Common specifications
I.S. EN 50124-1:2017 RAILWAY APPLICATIONS - INSULATION COORDINATION - PART 1: BASIC REQUIREMENTS - CLEARANCES AND CREEPAGE DISTANCES FOR ALL ELECTRICAL AND ELECTRONIC EQUIPMENT
IEC 62271-1:2017 High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear
IEC TR 62001:2009 High-voltage direct current (HVDC) systems - Guidebook to the specification and design evaluation of A.C. filters
I.S. EN 50123-7-2:2003 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 7-2: MEASUREMENT, CONTROL AND PROTECTION DEVICES FOR SPECIFIC USE IN D.C. TRACTION SYSTEMS - ISOLATING CURRENT TRANSDUCERS AND OTHER CURRENT MEASURING DEVICES
IEC 61462:2007 Composite hollow insulators - Pressurized and unpressurized insulators for use in electrical equipment with rated voltage greater than 1 000 V - Definitions, test methods, acceptance criteria and design recommendations
IEC TS 60815-3:2008 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 3: Polymer insulators for a.c. systems
IEC 60137:2017 RLV Insulated bushings for alternating voltages above 1000 V
IEC 60071-2:2018 RLV Insulation co-ordination - Part 2: Application guidelines
VDE 0674-1 : 2001-12 TESTS ON INDOOR AND OUTDOOR POST INSULATORS OF CERAMIC MATERIAL OR GLASS FOR SYSTEMS WITH NOMINAL VOLTAGES GREATER THAN 1 KV
BS 923-1:1990 Guide on high-voltage testing techniques General
VDE 0446-4 : 1995 INSULATORS FOR OVERHEAD LINES WITH A NOMINAL VOLTAGE ABOVE 1000 V - PART 2: INSULATOR STRINGS AND INSULATOR SETS FOR A.C. SYSTEMS - DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA
BS 6581:1995 Common clauses for high-voltage switchgear and controlgear standards
DIN EN 60383-2 : 1995 INSULATORS FOR OVERHEAD LINES WITH A NOMINAL VOLTAGE ABOVE 1000 V - PART 2: INSULATOR STRINGS AND INSULATOR SETS FOR A.C. SYSTEMS - DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA
DIN EN 60168 : 2001-12 TESTS ON INDOOR AND OUTDOOR POST INSULATORS OF CERAMIC MATERIAL OR GLASS FOR SYSTEMS WITH NOMINAL VOLTAGES GREATER THAN 1 KV
12/30253935 DC : DRAFT JUNE 2012 BS EN 62271-201 - HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - AC SOLID-INSULATED ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV
BS EN 60099-5:2013 Surge arresters Selection and application recommendations
17/30356577 DC : 0 BS EN 60099-8 - SURGE ARRESTERS - PART 8: METAL-OXIDE SURGE ARRESTERS WITH EXTERNAL SERIES GAP (EGLA) FOR OVERHEAD TRANSMISSION AND DISTRIBUTION LINES OF A.C. SYSTEMS ABOVE 1 KV
PD IEC/TR 62001-1:2016 High-voltage direct current (HVDC) systems. Guidance to the specification and design evaluation of AC filters Overview
BS EN 62271-103:2011 High-voltage switchgear and controlgear Switches for rated voltages above 1 kV up to and including 52 kV
12/30235047 DC : 0 BS EN 62146-1 ED.1 - GRADING CAPACITORS FOR HIGH-VOLTAGE ALTERNATING CURRENT CIRCUIT-BREAKERS
15/30314795 DC : 0 BS EN 50152-3-3 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR A.C. SWITCHGEAR - PART 3-3: MEASUREMENT, CONTROL AND PROTECTION DEVICES FOR SPECIFIC USE IN A.C. TRACTION SYSTEMS - SINGLE-PHASE INDUCTIVE VOLTAGE TRANSFORMERS
PREN 50152-3-3 : DRAFT 2015 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR A.C. SWITCHGEAR - PART 3-3: MEASUREMENT, CONTROL AND PROTECTION DEVICES FOR SPECIFIC USE IN A.C. TRACTION SYSTEMS - SINGLE-PHASE INDUCTIVE VOLTAGE TRANSFORMERS
UNE-EN 60137:2011 Insulated bushings for alternating voltages above 1 000 V
NFC 33 064 : 1999 INSULATED CABLES AND THEIR ACCESSORIES FOR POWER SYSTEMS - INDOOR OR OUTDOOR POLYMERIC TERMINATIONS, WITHOUT PORCELAIN INSULATOR, FOR SINGLE-CORE CABLES WITH POLYMERIC EXTRUDED INSULATION FOR RATED VOLTAGES ABOVE 30 KV (UM EQUAL TO 36 KV) UP TO 150 KV (UM EQUAL TO 170 KV)
BS EN 50123-7-1:2003 Railway applications. Fixed installations. d.c. switchgear. Measurement, control and protection devices for specific use in d.c. traction systems Measurement, control and protection devices for specific use in d.c. traction systems. Application guide
BS EN 60099-8:2011 Surge arresters Metal-oxide surge arresters with external series gap (EGLA) for overhead transmission and distribution lines of a.c. systems above 1 kV
IEEE 4-2013 IEEE Standard for High-Voltage Testing Techniques
15/30314792 DC : 0 BS EN 50152-3-2 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR A.C. SWITCHGEAR - PART 3-2: MEASUREMENT, CONTROL AND PROTECTION DEVICES FOR SPECIFIC USE IN A.C. TRACTION SYSTEMS - SINGLE-PHASE CURRENT TRANSFORMERS
BS 6581:1985 Specification for common requirements for high-voltage switchgear and controlgear standards
BS EN 62217:2013 Polymeric HV insulators for indoor and outdoor use. General definitions, test methods and acceptance criteria
CEI EN 50123-1 : 2003 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 1: GENERAL
04/30111589 DC : 0
BS EN 60143-2:2013 Series capacitors for power systems Protective equipment for series capacitor banks
BS EN 60383-2:1995 Insulators for overhead lines with a nominal voltage above 1000 V Insulator strings and insulator sets for a.c. systems. Definitions, test methods and acceptance criteria
UNE-EN 62271-103:2012 High-voltage switchgear and controlgear - Part 103: Switches for rated voltages above 1 kV up to and including 52 kV
CEI EN 60143-2 : 2014 SERIES CAPACITORS FOR POWER SYSTEMS - PART 2: PROTECTIVE EQUIPMENT FOR SERIES CAPACITOR BANKS
I.S. HD 597:2003 COUPLING CAPACITORS AND CAPACITOR DIVIDERS
BS EN 62271-1:2017 High-voltage switchgear and controlgear Common specifications for alternating current switchgear and controlgear
PREN 50152-1 : DRAFT 2011 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 1: CIRCUIT-BREAKERS WITH NOMINAL VOLTAGE ABOVE 1 KV
NF EN 60071-1 : 2006 AMD 1 2010 INSULATION CO-ORDINATION - PART 1: DEFINITIONS, PRINCIPLES AND RULES
I.S. EN 50152-3-2:2016 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR A.C. SWITCHGEAR - PART 3-2: MEASUREMENT, CONTROL AND PROTECTION DEVICES FOR SPECIFIC USE IN A.C. TRACTION SYSTEMS - SINGLE-PHASE CURRENT TRANSFORMERS
I.S. EN IEC 60071-2:2018 INSULATION CO-ORDINATION - PART 2: APPLICATION GUIDELINES
BIS IS/IEC 62271-1 : 2007 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 1: COMMON SPECIFICATIONS
CEI EN 50341-1 : 2013 OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS
I.S. EN 50152-2:2012 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 2: DISCONNECTORS, EARTHING SWITCHES AND SWITCHES WITH NOMINAL VOLTAGE ABOVE 1 KV
IEC 60071-2:2018 Insulation co-ordination - Part 2: Application guidelines
I.S. EN 60099-5:2013 SURGE ARRESTERS - PART 5: SELECTION AND APPLICATION RECOMMENDATIONS (IEC 60099-5:2013 (EQV))
IEC 61992-1:2006+AMD1:2014 CSV Railway applications - Fixed installations - DC switchgear - Part 1:General
IEC 62155:2003 Hollow pressurized and unpressurized ceramic and glass insulators for use in electrical equipment with rated voltages greater than 1 000 V
IEC TS 61245:2015 Artificial pollution tests on high-voltage ceramic and glass insulators to be used on d.c. systems
IEC 62271-111:2012 High-voltage switchgear and controlgear - Part 111: Automatic circuit reclosers and fault interrupters for alternating current systems up to 38 kV
UNE-EN 50152-3-2:2016 Railway applications - Fixed installations - Particular requirements for a.c. switchgear - Part 3-2: Measurement, control and protection devices for specific use in a.c. traction systems - Current transformers
IEC 61952:2008 Insulators for overhead lines - Composite line post insulators for A.C. systems with a nominal voltage greater than 1 000 V - Definitions, test methods and acceptance criteria
IEC 62217:2012 Polymeric HV insulators for indoor and outdoor use - General definitions, test methods and acceptance criteria
CEI EN 61442 : 2006 TEST METHODS FOR ACCESSORIES FOR POWER CABLES WITH RATED VOLTAGES FROM 6 KV (U[M] = 7,2 KV) UP TO 36 KV (U[M] = 42 KV)
11/30242675 DC : 0 BS EN 60099-4 F2 - SURGE ARRESTERS - PART 4: METAL-OXIDE SURGE ARRESTERS WITHOUT GAPS FOR A.C. SYSTEMS
EN IEC 60099-5:2018 Surge arresters - Part 5: Selection and application recommendations
BS 7912:2001 Power cables with XLPE insulation and metallic sheath, and their accessories, for rated voltages from 66 kV (<i>U</i><sub>m</sub>=72.5 kV) to 132kV (<i>U</i><sub>m</sub>=145kV). Requirements and test methods
12/30260570 DC : 0 BS EN 50341-1 - OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS
HD 553 : 200S2 CURRENT TRANSFORMERS
BS 7922:2004 Electric cables. Fluid-filled, paper- and PPL-insulated, metal-sheathed cables and accessories for alternating voltages up to and including 400 kV (<i>U</i><sub>m</sub> = 420 kV). Requirements and test methods
IEEE/IEC C37.60-2012 IEEE/IEC International Standard - High-voltage switchgear and controlgear - Part 111: Automatic circuit reclosers and fault interrupters for alternating current systems up to 38 kV
16/30340451 DC : DRAFT APR 2016 BS EN 60099-5 - SURGE ARRESTERS - PART 5: SELECTION AND APPLICATION RECOMMENDATIONS
BS EN 50123-2:2003 Railway applications. Fixed installations. D.C. switchgear D.C. circuit breakers
I.S. EN 60143-2:2013 SERIES CAPACITORS FOR POWER SYSTEMS - PART 2: PROTECTIVE EQUIPMENT FOR SERIES CAPACITOR BANKS (IEC 60143-2:2012 (EQV))
04/30111295 DC : 0
BS EN 60099-9:2014 Surge arresters Metal-oxide surge arresters without gaps for HVDC converter stations
BS EN 61952:2008 Insulators for overhead lines. Composite line post insulators for A.C. systems with a nominal voltage greater than 1000 V. Definitions, test methods and acceptance criteria
16/30318517 DC : 0 BS EN 60137 ED. 7.0 - INSULATED BUSHINGS FOR ALTERNATING VOLTAGES ABOVE 1000 V
11/30235283 DC : 0 BS EN 50152-2 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 2: DISCONNECTORS, EARTHING SWITCHES AND SWITCHES WITH NOMINAL VOLTAGE ABOVE 1 KV
BS EN 62231:2007 Composite station post insulators for substations with a.c. voltages greater than 1000 V up to 245 kV. Definitions, test methods and acceptance criteria
DIN EN 60071-2 : 1997 INSULATION CO-ORDINATION - PART 2: APPLICATION GUIDE
DD IEC/TS 60815-3:2008 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions Polymer insulators for a.c. systems
UNE-EN 50152-1:2013 Railway applications - Fixed installations - Particular requirements for alternating current switchgear - Part 1: Circuit-breakers with nominal voltage above 1 kV
CEI EN 60060-1 : 2015 HIGH-VOLTAGE TEST TECHNIQUES - PART 1: GENERAL DEFINITIONS AND TEST REQUIREMENTS
I.S. EN 50152-1:2012 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 1: CIRCUIT-BREAKERS WITH NOMINAL VOLTAGE ABOVE 1 KV
I.S. EN 61952:2008 INSULATORS FOR OVERHEAD LINES - COMPOSITE LINE POST INSULATORS FOR A.C. SYSTEMS WITH A NOMINAL VOLTAGE GREATER THAN 1 000 V - DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA
I.S. EN 60099-8:2011 SURGE ARRESTERS - PART 8: METAL-OXIDE SURGE ARRESTERS WITH EXTERNAL SERIES GAP (EGLA) FOR OVERHEAD TRANSMISSION AND DISTRIBUTION LINES OF A.C. SYSTEMS ABOVE 1 KV
I.S. EN 62217:2013 POLYMERIC HV INSULATORS FOR INDOOR AND OUTDOOR USE - GENERAL DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA (IEC 62217:2012 (EQV))
I.S. EN 50123-2:2003 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - D.C. CIRCUIT BREAKERS
EN 60383-2:1995 Insulators for overhead lines with a nominal voltage above 1 kV - Part 2: Insulator strings and insulator sets for a.c. systems - Definitions, test methods and acceptance criteria
I.S. EN 60099-4:2014 SURGE ARRESTERS - PART 4: METAL-OXIDE SURGE ARRESTERS WITHOUT GAPS FOR A.C. SYSTEMS
PREN 50152-2 : DRAFT 2011 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 2: DISCONNECTORS, EARTHING SWITCHES AND SWITCHES WITH NOMINAL VOLTAGE ABOVE 1 KV
CEI EN 50152-2 : 2013 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 2: DISCONNECTORS, EARTHING SWITCHES AND SWITCHES WITH NOMINAL VOLTAGE ABOVE 1 KV
IEC TR 62001-4:2016 High-voltage direct current (HVDC) systems - Guidance to the specification and design evaluation of AC filters - Part 4: Equipment
I.S. EN 50123-7-3:2003 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 7-3: MEASUREMENT, CONTROL AND PROTECTION DEVICES FOR SPECIFIC USE IN D.C. TRACTION SYSTEMS - ISOLATING VOLTAGE TRANSDUCERS AND OTHER VOLTAGE MEASURING DEVICES
I.S. EN 60060-1:2010 HIGH-VOLTAGE TEST TECHNIQUES - PART 1: GENERAL DEFINITIONS AND TEST REQUIREMENTS
IEC TR 62730:2012 HV polymeric insulators for indoor and outdoor use tracking and erosion testing by wheel test and 5 000h test
I.S. EN 62155:2003 HOLLOW PRESSURIZED AND UNPRESSURIZED CERAMIC AND GLASS INSULATORS FOR USE IN ELECTRICAL EQUIPMENT WITH RATED VOLTAGES GREATER THAN 1000 V
I.S. EN 60071-1:2006 INSULATION CO-ORDINATION - PART 1: DEFINITIONS, PRINCIPLES AND RULES
IEC 60071-1:2006+AMD1:2010 CSV Insulation co-ordination - Part 1: Definitions, principles and rules
IEC 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
UNE-EN 62271-201:2015 High-voltage switchgear and controlgear - Part 201: AC solid-insulation enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
UNE-EN 50152-3-3:2016 Railway applications - Fixed installations - Particular requirements for a.c. switchgear - Part 3-3: Measurement, control and protection devices for specific use in a.c. traction systems - Voltage transformers
IEC 60099-9:2014 Surge arresters - Part 9: Metal-oxide surge arresters without gaps for HVDC converter stations
IEC 60099-4:2014 Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems
IEC 62231:2006 Composite station post insulators for substations with a.c. voltages greater than 1 000 V up to 245 kV - Definitions, test methods and acceptance criteria
IEC 62223:2009 Insulators - Glossary of terms and definitions
IEC 60143-2:2012 Series capacitors for power systems - Part 2: Protective equipment for series capacitor banks
IEC 62271-103:2011 High-voltage switchgear and controlgear - Part 103: Switches for rated voltages above 1 kV up to and including 52 kV
EN 61462:2007 Composite hollow insulators - Pressurized and unpressurized insulators for use in electrical equipment with rated voltage greater than 1 000 V - Definitions, test methods, acceptance criteria and design recommendations
EN 50123-7-3:2003 Railway applications - Fixed installations - D.C. switchgear - Part 7-3: Measurement, control and protection devices for specific use in d.c. traction systems - Isolating voltage transducers and other voltage measuring devices
PREN 50341-1 : DRAFT 2012 OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS
BS EN 50152-1 : 2012 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 1: CIRCUIT-BREAKERS WITH NOMINAL VOLTAGE ABOVE 1 KV
UNE-EN 60060-1:2012 High-voltage test techniques - Part 1: General definitions and test requirements
BIS IS/IEC 60071-1 : 2006 INSULATION CO-ORDINATION - PART 1: DEFINITIONS, PRINCIPLES AND RULES
UNE-EN 62223:2011 Insulators - Glossary of terms and definitions
UNE-EN 62217:2013 Polymeric HV insulators for indoor and outdoor use - General definitions, test methods and acceptance criteria
HD 634 : 200S1 TESTS ON INTERNAL GAS-PRESSURE CABLES AND ACCESSORIES FOR ALTERNATING VOLTAGES UP TO AND INCLUDING 275 KV (UM = 300 KV)
02/207434 DC : 0 IEC 60815-2/TS. ED.1.0 - SELECTION AND DIMENSIONING OF HIGH-VOLTAGE INSULATORS FOR POLLUTED CONDITIONS - PART 2: CERAMIC AND GLASS INSULATORS FOR A.C. SYSTEMS
BS 7578:1992 Coupling capacitors and capacitor dividers
11/30243837 DC : 0 BS EN 62217 - POLYMERIC HV INSULATORS FOR INDOOR AND OUTDOOR USE - GENERAL DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA
11/30245197 DC : 0 BS EN 60143-2 - SERIES CAPACITORS FOR POWER SYSTEMS - PART 2: PROTECTIVE EQUIPMENTS FOR SERIES CAPACITOR BANKS
15/30265353 DC : 0 BS EN 62271-1 ED 2 - HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 1: COMMON SPECIFICATIONS FOR ALTERNATING CURRENT SWITCHGEAR AND CONTROLGEAR
BS EN 60694:1997 Common specifications for high-voltage switchgear and controlgear standards
BS EN 62271-201:2014 High-voltage switchgear and controlgear AC solid-insulation enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
PD IEC/TR 62001-4:2016 High-voltage direct current (HVDC) systems. Guidance to the specification and design evaluation of AC filters Equipment
BS EN 50124-1:2017 Railway applications. Insulation coordination Basic requirements. Clearances and creepage distances for all electrical and electronic equipment
02/206482 DC : 0 IEC 60815-1 TS ED.1.0 - SELECTION AND DIMENSIONING OF HIGH-VOLTAGE INSULATORS FOR POLLUTED CONDITIONS - PART 1: DEFINITIONS, INFORMATION AND GENERAL PRINCIPLES
IEEE C37.122.1-2014 IEEE Guide for Gas-Insulated Substations Rated Above 52 kV
93/209659 DC : DRAFT SEP 1993 EN 50124-1 INSULATION COORDINATION - PART 1 - BASIC REQUIREMENTS - CLEARANCE & CREEPAGES (CLC/TC9X/ WG6/13 APRIL 1993)
BS EN 62223:2009 Insulators. Glossary of terms and definitions
IEC 60137:2017 Insulated bushings for alternating voltages above 1000 V
CSA C62155 : 2006 : R2011 HOLLOW PRESSURIZED AND UNPRESSURIZED CERAMIC AND GLASS INSULATORS FOR USE IN ELECTRICAL EQUIPMENT WITH RATED VOLTAGES GREATER THAN 1000 V
NF EN 60099-8 : 2011 SURGE ARRESTERS - PART 8: METAL-OXIDE SURGE ARRESTERS WITH EXTERNAL SERIES GAP (EGLA) FOR OVERHEAD TRANSMISSION AND DISTRIBUTION LINES OF A.C. SYSTEMS ABOVE 1 KV
VDE 0111-2 : 1997 INSULATION CO-ORDINATION - PART 2: APPLICATION GUIDE
DIN IEC 60060-1 : 1994 HIGH VOLTAGE TEST TECHNIQUES - GENERAL SPECIFICATIONS AND TEST REQUIREMENTS
CSA C156.3 : 1986 : R2004 TEST METHODS FOR STATION POST INSULATORS
BS EN 50152-2:2012 Railway applications. Fixed installations. Particular requirements for alternating current switchgear Disconnectors, earthing switches and switches with nominal voltage above 1 kV
CEI EN 60071-2 : 1998 INSULATION CO-ORDINATION - PART 2: APPLICATION GUIDE
EN IEC 60071-2:2018 Insulation co-ordination - Part 2: Application guidelines
I.S. EN IEC 60099-5:2018 SURGE ARRESTERS - PART 5: SELECTION AND APPLICATION RECOMMENDATIONS
I.S. EN 50341-1:2012 OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS
I.S. EN 60099-9:2014 SURGE ARRESTERS - PART 9: METAL-OXIDE SURGE ARRESTERS WITHOUT GAPS FOR HVDC CONVERTER STATIONS
CEI EN 60099-9 : 2015 SURGE ARRESTERS - PART 9: METAL-OXIDE SURGE ARRESTERS WITHOUT GAPS FOR HVDC CONVERTER STATIONS
BS EN 60099-4:2014 Surge arresters Metal-oxide surge arresters without gaps for a.c. systems
CEI EN 60137 : 2009 INSULATED BUSHINGS FOR ALTERNATING VOLTAGES ABOVE 1000 V
CEI EN 60099-8 : 2012 SURGE ARRESTERS - PART 8: METAL-OXIDE SURGE ARRESTERS WITH EXTERNAL SERIES GAP (EGLA) FOR OVERHEAD TRANSMISSION AND DISTRIBUTION LINES OF A.C. SYSTEMS ABOVE 1 KV
BS EN 60071-1 : 2006 INSULATION CO-ORDINATION - PART 1: DEFINITIONS, PRINCIPLES AND RULES
NFC 33 063 : 1999 INSULATED CABLES AND THEIR ACCESSORIES FOR POWER SYSTEMS - OUTDOOR TERMINATIONS, WITH PORCELAIN INSULATOR, FOR SINGLE-CORE CABLES WITH POLYMERIC EXTRUDED INSULATION FOR RATED VOLTAGES ABOVE 30 KV (UM EQUAL TO 36 KV) UP TO 500 KV (UM EQUAL TO 525 KV)
I.S. HD 633:1999 TESTS ON OIL-FILLED (FLUID FILLED), PAPER- OR POLYPROPYLENE PAPER LAMINATED-INSULATED, METAL-SHEATHED CABLES AND ACCESSORIES FOR ALTERNATING VOLTAGES UP TO AND INCLUDING 400 KV (UM = 420 KV)
I.S. EN 62271-103:2011 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 103: SWITCHES FOR RATED VOLTAGES ABOVE 1 KV UP TO AND INCLUDING 52 KV
I.S. EN 62271-1:2017 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 1: COMMON SPECIFICATIONS FOR ALTERNATING CURRENT SWITCHGEAR AND CONTROLGEAR
IEC 62505-1:2016 Railway applications - Fixed installations - Particular requirements for AC switchgear - Part 1: Circuit-breakers with nominal voltage above 1 kV
I.S. EN 62271-201:2014 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 201: AC SOLID-INSULATION ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV
IEC 62271-201:2014 High-voltage switchgear and controlgear - Part 201: AC solid-insulation enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
EN 50152-2:2012 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 2: DISCONNECTORS, EARTHING SWITCHES AND SWITCHES WITH NOMINAL VOLTAGE ABOVE 1 KV
EN 50123-7-1:2003 Railway applications - Fixed installations - D.C. switchgear - Part 7-1: Measurement, control and protection devices for specific use in d.c. traction systems - Application guide
EN 50123-1:2003 Railway applications - Fixed installations - D.C. switchgear - Part 1: General
EN 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
EN 50123-4:2003/A1:2013 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 4: OUTDOOR D.C. DISCONNECTORS, SWITCH-DISCONNECTORS AND EARTHING SWITCHES
EN 50123-2:2003 Railway applications - Fixed installations - D.C. switchgear - Part 2: D.C. circuit breakers
EN 60099-9:2014 Surge arresters - Part 9: Metal-oxide surge arresters without gaps for HVDC converter stations
EN 60143-2:2013 Series capacitors for power systems - Part 2: Protective equipment for series capacitor banks
EN 50152-1 : 2012 AMD 1 2013 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 1: CIRCUIT-BREAKERS WITH NOMINAL VOLTAGE ABOVE 1 KV
EN 62217:2013 Polymeric HV insulators for indoor and outdoor use - General definitions, test methods and acceptance criteria
IEC 60099-8:2017 RLV Surge arresters - Part 8: Metal-oxide surge arresters with external series gap (EGLA) for overhead transmission and distribution lines of a.c. systems above 1 kV
EN 60099-5:2013 Surge arresters - Part 5: Selection and application recommendations
EN 50123-3:2003/A1:2013 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 3: INDOOR D.C. DISCONNECTORS, SWITCH-DISCONNECTORS AND EARTHING SWITCHES
CSA C71.2 : 1998 INSULATION COORDINATION - PART 2: APPLICATION GUIDE

IEC TS 60815-2:2008 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 2: Ceramic and glass insulators for a.c. systems
IEC 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
IEC 60071-1:2006+AMD1:2010 CSV Insulation co-ordination - Part 1: Definitions, principles and rules
IEC TS 60815-1:2008 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 1: Definitions, information and general principles

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.