IEC 60947-5-2:2007+AMD1:2012 CSV
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Low-voltage switchgear and controlgear - Part 5-2: Control circuitdevices and switching elements - Proximity switches
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
24-10-2019
English - French
27-09-2012
FOREWORD
1 General
2 Definitions
3 Classification
4 Characteristics
5 Product information
6 Normal service, mounting and transport conditions
7 Constructional and performance requirements
8 Tests
Annex A (informative) - Typical dimensions and operating
distances of proximity switches
Annex B (normative) - Class II proximity switches insulated
by encapsulation - Requirements and tests
Annex C (normative) - Additional requirements for proximity
switches with integrally connected cables
Annex D (normative) - Integral connectors for plug-in proximity
switches
Annex E (normative) - Additional requirements for proximity
switches suitable for use in strong magnetic fields
Annex F (informative) - Symbols for proximity switches
IEC 60947-5-2:2007+A1:2012 applies to inductive and capacitive proximity switches that sense the presence of metallic and/or non-metallic objects, ultrasonic proximity switches that sense the presence of sound reflecting objects, photoelectric proximity switches that sense the presence of objects and non-mechanical magnetic proximity switches that sense the presence of objects with a magnetic field. These proximity switches are self-contained, have semiconductor switching elements(s) and are intended to be connected to circuits, the rated voltage of which does not exceed 250 V 50 Hz/60 Hz a.c. or 300 V d.c. This Standard is not intended to cover proximity switches with analogue outputs. The main changes with respect to the previous edition are as follows:
- modification of Table 3;
- modifications of voltage dips and voltage interruptions immunity tests, in Table 8;
- modification of status of Annex A, now informative.
This consolidated version consists of the third edition (2007) and its amendment 1 (2012). Therefore, no need to order amendment inaddition to this publication.
DevelopmentNote |
Stability Date: 2019. (09/2017)
|
DocumentType |
Standard
|
Pages |
207
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
JIS C 8201-5-2:2017 | Identical |
OVE/ONORM EN 60947-5-2 : 2014 | Identical |
CEI EN IEC 60947-5-2 : 2020 | Identical |
GOST IEC 60947-5-2 : 2012 | Identical |
NEN EN IEC 60947-5-2 : 2008 AMD 1 2012 | Identical |
PN EN 60947-5-2 : 2011 AMD 1 2013 | Identical |
AS/NZS IEC 60947.5.2:2015 | Identical |
DIN EN 60947-5-2 : 2014-01 | Identical |
VDE 0660-208 : 2014 | Identical |
UNE-EN 60947-5-2:2008 | Identical |
BS EN 60947-5-2 : 2007 | Identical |
EN 60947-5-2:2007/A1:2012 | Identical |
BIS IS/IEC 60947-5-2 : 2007(R2017) | Identical |
I.S. EN 60947-5-2:2008 | Identical |
SAC GB/T 14048.10 : 1999 | Identical |
CEI 17-53 : 1ED 1997 | Identical |
SN EN 60947-5-2 : 1998 AMD 1 1999 | Identical |
NF EN 60947 5-2 : 2008 AMD 1 2013 | Identical |
UNE-EN 60947-5-3:2014 | Low-voltage switchgear and controlgear - Part 5-3: Control circuit devices and switching elements - Requirements for proximity devices with defined behaviour under fault conditions (PDDB) |
97/207799 DC : DRAFT JUL 1997 | IEC 62026-3 - CONTROL CIRCUIT DEVICES AND SWITCHING ELEMENTS FOR LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 3: DEVICE NETWORK (DN) |
CEI EN 60947-5-3 : 2014 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 5-3: CONTROL CIRCUIT DEVICES AND SWITCHING ELEMENTS - REQUIREMENTS FOR PROXIMITY DEVICES WITH DEFINED BEHAVIOUR UNDER FAULT CONDITIONS (PDDB) |
NF EN 60947-5-7 : 2003 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 5-7: CONTROL CIRCUIT DEVICES AND SWITCHING ELEMENTS - REQUIREMENTS FOR PROXIMITY DEVICES WITH ANALOGUE OUTPUT |
BS EN 60947-5-7:2003 | Specification for low-voltage switchgear and controlgear. Control circuit devices and switching elements Requirements for proximity devices with analogue output |
VDE 0660-212 : 2000 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 5-6: CONTROL CIRCUIT DEVICES AND SWITCHING ELEMENTS - DC INTERFACE FOR PROXIMITY SENSORS AND SWITCHING AMPLIFIERS (NAMUR) |
I.S. EN 62683-1:2017 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PRODUCT DATA AND PROPERTIES FOR INFORMATION EXCHANGE - PART 1: CATALOGUE DATA |
CENELEC GUIDE 28 : 2006 | ACCESSIBILITY IN INTERFACES IN LOW VOLTAGE ELECTRICAL INSTALLATIONS - A GUIDE FOR STANDARD WRITERS |
ISO 14990-1:2016 | Earth-moving machinery — Electrical safety of machines utilizing electric drives and related components and systems — Part 1: General requirements |
EN 62683-1:2017 | Low-voltage switchgear and controlgear - Product data and properties for information exchange - Part 1: Catalogue data |
DIN EN 60947-5-6 : 2000 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 5-6: CONTROL CIRCUIT DEVICES AND SWITCHING ELEMENTS, DC INTERFACE FOR PROXIMITY SENSORS AND SWITCHING AMPLIFIERS (NAMUR) |
BS EN 62026-2:2013 | Low-voltage switchgear and controlgear. Controller-device interfaces (CDIs) Actuator sensor interface (AS-i) |
BS EN 62026-3:2015 | Low-voltage switchgear and controlgear. Controller-device interfaces (CDIs) DeviceNet |
15/30286010 DC : 0 | BS ISO 14990-1 - EARTH-MOVING MACHINERY - ELECTRICAL SAFETY OF MACHINES UTILISING ELECTRIC DRIVES AND RELATED COMPONENTS AND SYSTEMS - PART 1: GENERAL REQUIREMENTS |
IEC 60947-5-9:2006 | Low-voltage switchgear and controlgear - Part 5-9: Control circuit devices and switching elements - Flow rate switches |
UNE-EN ISO 14119:2014 | Safety of machinery - Interlocking devices associated with guards - Principles for design and selection (ISO 14119:2013) |
IEC 62026-3:2014 | Low-voltage switchgear and controlgear - Controller-device interfaces (CDIs) - Part 3: DeviceNet |
EN 61158-2:2014 | Industrial communication networks - Fieldbus specifications - Part 2: Physical layer specification and service definition |
EN ISO 14119:2013 | Safety of machinery - Interlocking devices associated with guards - Principles for design and selection (ISO 14119:2013) |
EN 61131-2:2007 | Programmable controllers - Part 2: Equipment requirements and tests |
EN 62683:2015 | Low-voltage switchgear and controlgear - Product data and properties for information exchange |
BS EN IEC 62246-1-1:2018 | Reed switches Generic specification. Blank detail specification |
17/30336631 DC : 0 | BS EN 62246-1-1 - REED SWITCHES - PART 1-1: DETAIL SPECIFICATION - QUALITY ASSESSMENT |
NF EN 60947-5-3 : 2014 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 5-3: CONTROL CIRCUIT DEVICES AND SWITCHING ELEMENTS - REQUIREMENTS FOR PROXIMITY DEVICES WITH DEFINED BEHAVIOUR UNDER FAULT CONDITIONS (PDDB) |
03/100498 DC : DRAFT JUNE 2003 | IEC 60947-5-3 AMD 1. ED 1 - LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 5-3: CONTROL CIRCUIT DEVICES AND SWITCHING ELEMENTS - REQUIREMENTS FOR PROXIMITY DEVICES WITH DEFINED BEHAVIOUR UNDER FAULT CONDITIONS (PDF) |
IEC 62683-1:2017 | Low-voltage switchgear and controlgear - Product data and properties for information exchange - Part 1: Catalogue data |
I.S. EN 60947-5-7:2003 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 5-7: CONTROL CIRCUIT DEVICES AND SWITCHING ELEMENTS - REQUIREMENTS FOR PROXIMITY DEVICES WITH ANALOGUE OUTPUT |
I.S. EN ISO 14119:2013 | SAFETY OF MACHINERY - INTERLOCKING DEVICES ASSOCIATED WITH GUARDS - PRINCIPLES FOR DESIGN AND SELECTION (ISO 14119:2013) |
I.S. EN 50325-1:2002 | INDUSTRIAL COMMUNICATIONS SUBSYSTEM BASED ON ISO 11898 (CAN) FOR CONTROLLER-DEVICE INTERFACES - PART 1: GENERAL REQUIREMENTS |
IEC 62026-2:2008 | Low-voltage switchgear and controlgear - Controller-device interfaces (CDIs) - Part 2: Actuator sensor interface (AS-i) |
I.S. EN 62683:2015 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PRODUCT DATA AND PROPERTIES FOR INFORMATION EXCHANGE |
CEI EN 61131-9 : 2014 | PROGRAMMABLE CONTROLLERS - PART 9: SINGLE-DROP DIGITAL COMMUNICATION INTERFACE FOR SMALL SENSORS AND ACTUATORS (SDCI) |
ISO 20401:2017 | Pneumatic fluid power systems — Directional control valves — Specification of pin assignment for 8 mm and 12 mm diameter electrical round connectors |
I.S. EN 60204-32:2008 | SAFETY OF MACHINERY - ELECTRICAL EQUIPMENT OF MACHINES - PART 32: REQUIREMENTS FOR HOISTING MACHINES |
EN 62026-3:2015 | Low-voltage switchgear and controlgear - Controller-device interfaces (CDIs) - Part 3: DeviceNet |
IEC 60204-33:2009 | Safety of machinery - Electrical equipment of machines - Part 33: Requirements for semiconductor fabrication equipment |
17/30370043 DC : 0 | BS IEC 62026-2 AMD.1 ED.2.0 - LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - CONTROLLER-DEVICE INTERFACES (CDIS) - PART 2: ACTUATOR SENSOR INTERFACE (AS-I). |
BS EN 61131-2:2007 | Programmable controllers Equipment requirements and tests |
09/30205023 DC : 0 | BS EN 61158-2 - INDUSTRIAL COMMUNICATION NETWORKS - FIELDBUS SPECIFICATIONS - PART 2: PHYSICAL LAYER SPECIFICATION AND SERVICE DEFINITION |
06/30154990 DC : 0 | BS EN 60204-32 - SAFETY OF MACHINERY - ELECTRICAL EQUIPMENT OF MACHINES - PART 32: REQUIREMENTS FOR HOISTING MACHINES |
C22.2 NO. 205-17 | Signal equipment |
EN 60947-1:2007/A2:2014 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 1: GENERAL RULES (IEC 60947-1:2007/A2:2014) |
I.S. EN ISO 13850:2015 | SAFETY OF MACHINERY - EMERGENCY STOP FUNCTION - PRINCIPLES FOR DESIGN (ISO 13850:2015) |
00/716535 DC : DRAFT NOV 2000 | ISO/CD 20401 - FLUID POWER SYSTEMS - DIRECTIONAL CONTROL VALVES - SPECIFICATION OF PIN ASSIGNMENT FOR ELECTRICAL ROUND CONNECTORS OF DIAMETERS 8 MM AND 12 MM |
16/30330392 DC : 0 | BS ISO 20401 - PNEUMATIC FLUID POWER SYSTEMS - DIRECTIONAL CONTROL VALVES - SPECIFICATION OF PIN ASSIGNMENT FOR ELECTRICAL ROUND CONNECTORS OF DIAMETERS 8 MM AND 12 MM |
I.S. EN 62026-2:2013 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - CONTROLLER-DEVICE INTERFACES (CDIS) - PART 2: ACTUATOR SENSOR INTERFACE (AS-I) (IEC 62026-2:2008 (MOD)) |
BS EN 60947-5-3:2013 | Low-voltage switchgear and controlgear Control circuit devices and switching elements. Requirements for proximity devices with defined behaviour under fault conditions (PDDB) |
06/30148723 DC : DRAFT APR 2006 | IEC 62026-3 ED.2.0 - LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - CONTROLLER-DEVICE INTERFACES (C DIS) - PART 3: DEVICENET |
CEI EN 60947-5-9 : 2008 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 5-9: CONTROL CIRCUIT DEVICES AND SWITCHING ELEMENTS - FLOW RATE SWITCHES |
NF EN 60947-5-6 : 2000 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 5-6: CONTROL CIRCUIT DEVICES AND SWITCHING ELEMENTS - DC INTERFACE FOR PROXIMITY SENSORS AND SWITCHING AMPLIFIERS (NAMUR) |
BS EN 50325-2:2001 | Industrial communication subsystem based on ISO 11898 (CAN) for controller-device interfaces DeviceNet |
BS ISO 20401:2017 | Pneumatic fluid power systems. Directional control valves. Specification of pin assignment for 8 mm and 12 mm diameter electrical round connectors |
BS EN 50325-1:2002 | Industrial communication subsystem based on ISO 11898 (CAN) for controller-device interfaces General requirements |
09/30193520 DC : 0 | BS EN 60947-5-3 - LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 5-3: CONTROL CIRCUIT DEVICES AND SWITCHING ELEMENTS - REQUIREMENTS FOR PROXIMITY DEVICES WITH DEFINED BEHAVIOUR UNDER FAULT CONDITIONS (PDF) |
ISO 16860:2005 | Hydraulic fluid power — Filters — Test method for differential pressure devices |
BS EN 61784-5-2:2013 | Industrial communication networks. Profiles Installation of fieldbuses. Installation profiles for CPF 2 |
I.S. EN 61158-2:2014 | INDUSTRIAL COMMUNICATION NETWORKS - FIELDBUS SPECIFICATIONS - PART 2: PHYSICAL LAYER SPECIFICATION AND SERVICE DEFINITION |
EN 60204-1 : 2006 COR 2010 | SAFETY OF MACHINERY - ELECTRICAL EQUIPMENT OF MACHINES - PART 1: GENERAL REQUIREMENTS |
I.S. EN 60947-5-3:2013 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 5-3: CONTROL CIRCUIT DEVICES AND SWITCHING ELEMENTS - REQUIREMENTS FOR PROXIMITY DEVICES WITH DEFINED BEHAVIOUR UNDER FAULT CONDITIONS (PDDB) |
CEI EN 60947-5-7 : 2005 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 5-7: CONTROL CIRCUIT DEVICES AND SWITCHING ELEMENTS - REQUIREMENTS FOR PROXIMITY DEVICES WITH ANALOGUE OUTPUT |
EN IEC 62246-1-1:2018 | Reed switches - Part 1-1: Generic specification - Blank detail specification |
API 551 : 2016 | PROCESS MEASUREMENT |
I.S. EN 62026-3:2015 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - CONTROLLER-DEVICE INTERFACES (CDIS) - PART 3: DEVICENET |
IEC 60204-1:2016 | Safety of machinery - Electrical equipment of machines - Part 1: General requirements |
I.S. EN 60204-1:2006 | SAFETY OF MACHINERY - ELECTRICAL EQUIPMENT OF MACHINES - PART 1: GENERAL REQUIREMENTS |
NF EN 50325-1 : 2003 | INDUSTRIAL COMMUNICATIONS SUBSYSTEM BASED ON ISO 11898 (CAN) FOR CONTROLLER-DEVICE INTERFACES - PART 1: GENERAL REQUIREMENTS |
IEC 61158-2:2014 | Industrial communication networks - Fieldbus specifications - Part 2: Physical layer specification and service definition |
12/30264905 DC : 0 | BS EN 61158-2 - INDUSTRIAL COMMUNICATION NETWORKS - FIELDBUS SPECIFICATIONS - PART 2: PHYSICAL LAYER SPECIFICATION AND SERVICE DEFINITION |
IEC 60947-5-3:2013 | Low-voltage switchgear and controlgear - Part 5-3: Control circuit devices and switching elements - Requirements for proximity devices with defined behaviour under fault conditions (PDDB) |
CEI EN 62026-2 : 2013 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - CONTROLLER-DEVICE INTERFACES (CDIS) - PART 2: ACTUATOR SENSOR INTERFACE (AS-I) |
UNE-EN 60204-1:2007 | Safety of machinery - Electrical equipment of machines - Part 1: General requirements |
UNI EN ISO 14119 : 2013 | SAFETY OF MACHINERY - INTERLOCKING DEVICES ASSOCIATED WITH GUARDS - PRINCIPLES FOR DESIGN AND SELECTION |
NF EN 60947-5-9 : 2008 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 5-9: CONTROL CIRCUIT DEVICES AND SWITCHING ELEMENTS - FLOW RATE SWITCHES |
BS EN 60947-1 : 2007 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 1: GENERAL RULES |
NF EN 62026-3:2015 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - CONTROLLER-DEVICE INTERFACES (CDIS) - PART 3: DEVICENET |
BS ISO 16860:2005 | Hydraulic fluid power. Filters. Test method for differential pressure devices |
DIN EN ISO 14119:2014-03 | Safety of machinery - Interlocking devices associated with guards - Principles for design and selection (ISO 14119:2013) |
SAE ARP 1558 : 2014(R 2019) | INTERFACE PROTECTION - GROUND EQUIPMENT TO AIRCRAFT |
BS EN 60947-5-6:2001 | Specification for low-voltage switchgear and controlgear. Control circuit devices and switching elements DC interface for proximity sensors and switching amplifiers (NAMUR) - DC interface for proximity sensors and switching amplifiers (NAMUR) |
I.S. EN IEC 62246-1-1:2018 | REED SWITCHES - PART 1-1: GENERIC SPECIFICATION - BLANK DETAIL SPECIFICATION |
BS EN 62683:2015 | Low-voltage switchgear and controlgear. Product data and properties for information exchange |
EN 62026-2:2013 | Low-voltage switchgear and controlgear - Controller-device interfaces (CDIs) - Part 2: Actuator sensor interface (AS-i) |
I.S. EN 61784-5-2:2013 | INDUSTRIAL COMMUNICATION NETWORKS - PROFILES - PART 5-2: INSTALLATION OF FIELDBUSES - INSTALLATION PROFILES FOR CPF 2 |
I.S. EN 61131-2:2007 | PROGRAMMABLE CONTROLLERS - PART 2: EQUIPMENT REQUIREMENTS AND TESTS |
IEC 61131-2:2017 | Industrial-process measurement and control - Programmable controllers - Part 2: Equipment requirements and tests |
IEC 60947-5-7:2003 | Low-voltage switchgear and controlgear - Part 5-7: Control circuit devices and switching elements - Requirements for proximity devices with analogue output |
EN 50325-1:2002 | Industrial communications subsystem based on ISO 11898 (CAN) for controller-device interfaces - Part 1: General requirements |
DIN EN 61158-2:2015-02 | INDUSTRIAL COMMUNICATION NETWORKS - FIELDBUS SPECIFICATIONS - PART 2: PHYSICAL LAYER SPECIFICATION AND SERVICE DEFINITION (IEC 61158-2:2014) |
BS EN 61158-2:2014 | Industrial communication networks. Fieldbus specifications Physical layer specification and service definition |
14/30238347 DC : 0 | BS EN 60204-1 ED 6.0 - SAFETY OF MACHINERY - ELECTRICAL EQUIPMENT OF MACHINES - PART 1: GENERAL REQUIREMENTS |
13/30292412 DC : 0 | BS EN 62683 - PRODUCT DATA AND PROPERTIES FOR INFORMATION EXCHANGE |
IEC 60947-5-6:1999 | Low-voltage switchgear and controlgear - Part 5-6: Control circuit devices and switching elements - DC interface for proximity sensors and switching amplifiers (NAMUR) |
ISO 14119:2013 | Safety of machinery — Interlocking devices associated with guards — Principles for design and selection |
IEC 61784-5-2:2013 | Industrial communication networks - Profiles - Part 5-2: Installation of fieldbuses - Installation profiles for CPF 2 |
IEC 61131-9:2013 | Programmable controllers - Part 9: Single-drop digital communication interface for small sensors and actuators (SDCI) |
ISO 22734-2:2011 | Hydrogen generators using water electrolysis process Part 2: Residential applications |
IEC 60947-1:2007+AMD1:2010+AMD2:2014 CSV | Low-voltage switchgear and controlgear - Part 1: General rules |
12/30261041 DC : 0 | BS EN 62026-3 - LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - CONTROLLER-DEVICE INTERFACES (CDIS) - PART 3: DEVICENET |
BS EN 60204-33:2011 | Safety of machinery. Electrical equipment of machines Requirements for semiconductor fabrication equipment |
BS ISO 14990-1:2016 | Earth-moving machinery. Electrical safety of machines utilizing electric drives and related components and systems General requirements |
BS ISO 22734-2:2011 | Hydrogen generators using water electrolysis process Residential applications |
EN ISO 13850:2015 | Safety of machinery - Emergency stop function - Principles for design (ISO 13850:2015) |
BS EN 62683-1:2017 | Low-voltage switchgear and controlgear. Product data and properties for information exchange Catalogue data |
BS EN 61131-9:2013 | Programmable controllers Single-drop digital communication interface for small sensors and actuators (SDCI) |
11/30203207 DC : 0 | BS EN ISO 14119 - SAFETY OF MACHINERY - INTERLOCKING DEVICES ASSOCIATED WITH GUARDS - PRINCIPLES FOR DESIGN AND SELECTION |
BS EN ISO 14119:2013 | Safety of machinery. Interlocking devices associated with guards. Principles for design and selection |
CEI EN 60947-5-6 : 2000 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 5-6: CONTROL CIRCUIT DEVICES AND SWITCHING ELEMENTS DC INTERFACE FOR PROXIMITY SENSORS AND SWITCHING AMPLIFIERS (NAMUR) |
05/30132835 DC : DRAFT APR 2005 | IEC 60947-5-9 - LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 5-9: CONTROL CIRCUIT DEVICES AND SWITCHING ELEMENTS - FLOW RATE SWITCHES |
BS EN 60947-5-9:2007 | Low-voltage switchgear and controlgear Control circuit devices and switching elements. Flow rate switches |
CSA E61131.2 :2006 | PROGRAMMABLE CONTROLLERS - PART 2: EQUIPMENT REQUIREMENTS AND TESTS |
97/207801 DC : DRAFT JUL 1997 | IEC 62026-5 - CONTROL CIRCUIT DEVICES AND SWITCHING ELEMENTS FOR LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 5: SMART DISTRIBUTED SYSTEM (SDS) |
UNE-EN 62683:2016 | Low-voltage switchgear and controlgear - Product data and properties for information exchange |
CSA E61131.2 : 2006 : R2016 | PROGRAMMABLE CONTROLLERS - PART 2: EQUIPMENT REQUIREMENTS AND TESTS |
DIN ISO 20401:2007-07 | Pneumatic fluid power systems - Directional control valves - Specification of pin assignment for electrical round connectors of diameters 8 mm and 12 mm (ISO 20401:2005 + Cor. 1:2005) |
I.S. EN 60947-5-9:2007 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 5-9: CONTROL CIRCUIT DEVICES AND SWITCHING ELEMENTS - FLOW RATE SWITCHES |
I.S. EN 60947-1:2007 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 1: GENERAL RULES |
I.S. EN 61131-9:2013 | PROGRAMMABLE CONTROLLERS - PART 9: SINGLE-DROP DIGITAL COMMUNICATION INTERFACE FOR SMALL SENSORS AND ACTUATORS (SDCI) |
CEI EN 61784-5-2 : 2014 | INDUSTRIAL COMMUNICATION NETWORKS - PROFILES - PART 5-2: INSTALLATION OF FIELDBUSES - INSTALLATION PROFILES FOR CPF 2 |
I.S. EN 60204-33:2011 | SAFETY OF MACHINERY - ELECTRICAL EQUIPMENT OF MACHINES - PART 33: REQUIREMENTS FOR SEMICONDUCTOR FABRICATION EQUIPMENT |
IEC 62026-5:2000 | Low-voltage switchgear and controlgear - Controller-device interfaces (CDIs) - Part 5: Smart distributed system (SDS) |
BS ISO 22734-1:2008 | Hydrogen generators using water electrolysis process Industrial and commercial applications |
IEC 60204-32:2008 | Safety of machinery - Electrical equipment of machines - Part 32: Requirements for hoisting machines |
ISO 22734-1:2008 | Hydrogen generators using water electrolysis process Part 1: Industrial and commercial applications |
BS EN 60204-1 : 2006 | SAFETY OF MACHINERY - ELECTRICAL EQUIPMENT OF MACHINES - PART 1: GENERAL REQUIREMENTS |
BS EN 60204-32:2008 | Safety of machinery. Electrical equipment of machines Requirements for hoisting machines |
06/30148719 DC : DRAFT APR 2006 | IEC 62026-2 ED.2 - LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - CONTROLLER-DEVICE INTERFACES (C DIS) - PART 2: ACTUATOR SENSOR INTERFACE (AS-I) |
EN 60947-5-7:2003 | Low-voltage switchgear and controlgear - Part 5-7: Control circuit devices and switching elements - Requirements for proximity devices with analogue output |
EN 60947-5-3:2013 | Low-voltage switchgear and controlgear - Part 5-3: Control circuit devices and switching elements - Requirements for proximity devices with defined behaviour under fault conditions (PDDB) |
UNE-ISO 22734-1:2012 | Hydrogen generators using water electrolysis process. Part 1: Industrial and commercial applications |
EN 61784-5-2:2013 | Industrial communication networks - Profiles - Part 5-2: Installation of fieldbuses - Installation profiles for CPF 2 |
EN 60204-32:2008 | Safety of machinery - Electrical equipment of machines - Part 32: Requirements for hoisting machines |
EN 60204-33:2011 | Safety of machinery - Electrical equipment of machines - Part 33: Requirements for semiconductor fabrication equipment |
EN 60947-5-6:2000 | Low-voltage switchgear and controlgear - Part 5-6: Control circuit devices and switching elements - DC interface for proximity sensors and switching amplifiers (NAMUR) |
EN 60947-5-9:2007 | Low-voltage switchgear and controlgear - Part 5-9: Control circuit devices and switching elements - Flow rate switches |
EN 61131-9 : 2013 | Programmable controllers - Part 9: Single-drop digital communication interface for small sensors and actuators (SDCI) |
IEC 60068-2-27:2008 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
IEC 61000-4-11:2004+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests |
IEC 60050-441:1984 | International Electrotechnical Vocabulary (IEV) - Part 441: Switchgear, controlgear and fuses |
IEC 61000-4-8:2009 | Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
IEC 61000-4-6:2013 | Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
IEC 60947-1:2007+AMD1:2010+AMD2:2014 CSV | Low-voltage switchgear and controlgear - Part 1: General rules |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
IEC 61000-3-3:2013 RLV | Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection |
ISO 630:1995 | Structural steels Plates, wide flats, bars, sections and profiles |
CISPR 11:2015 RLV | Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement |
IEC 61140:2016 | Protection against electric shock - Common aspects for installation and equipment |
IEC 60068-2-14:2009 | Environmental testing - Part 2-14: Tests - Test N: Change of temperature |
IEC 60445:2017 | Basic and safety principles for man-machine interface, marking and identification - Identification of equipment terminals, conductor terminations and conductors |
IEC 61000-4-13:2002+AMD1:2009+AMD2:2015 CSV | Electromagnetic compatibility (EMC) - Part 4-13: Testing and measurement techniques - Harmonics and interharmonics includingmains signalling at a.c. power port, low frequency immunity tests |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.