• Shopping Cart
    There are no items in your cart

IEC 60332-1-2:2004+AMD1:2015 CSV

Current

Current

The latest, up-to-date edition.

Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulatedwire or cable - Procedure for 1 kW pre-mixed flame

Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English - French

Published date

28-07-2015

€83.17
Excluding VAT

IEC 60332-1-2:2004+A1:2015 Specifies the procedure for testing the resistance to vertical flame propagation for a single vertical electrical insulated conductor or cable, or optical fibre cable, under fire conditions. The apparatus is given in IEC 60332-1-1.
NOTE 1 Testing to IEC 60332-1-2 may be performed simultaneously with that to IEC 60332-1-3 if required. Recommended requirements for performance are given in Annex A. IEC 60332-1-2 specifies the use of a 1 kW pre-mixed flame and is for general use, except that the procedure specified may not be suitable for the testing of small single insulated conductors or cables of less than 0,5 mm² total cross-section because the conductor melts before the test is completed, or for the testing of small optical fibre cables because the cable is broken before the test is completed. In these cases, the procedure given in IEC 60332-2-2 is recommended.
NOTE 2 Since the use of insulated conductor or cable which retards flame propagation and complies with the recommended requirements of this standard is not sufficient by itself to prevent propagation of fire under all conditions of installation, it is recommended that wherever the risk of propagation is high, for example in long vertical runs of bunches of cables, special installation precautions should also be taken. It cannot be assumed that because the sample of cable complies with the performance requirements recommended in this standard, that a bunch of cables will behave in a similar manner. (See IEC 60332-3 series.)
This consolidated version consists of the first edition (2004) and its amendment 1 (2015). Therefore, no need to order amendment in addition to this publication.

DevelopmentNote
Together with IEC 60332-1-1 supersedes IEC 60332-1. (07/2004) Stability Date: 2021. (07/2015)
DocumentType
Standard
Pages
48
PublisherName
International Electrotechnical Committee
Status
Current
Supersedes

NFC 32 102-15 : 2007 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 15: MULTICORE CABLES INSULATED AND SHEATHED WITH HEAT RESISTANT SILICONE RUBBER
UNE-EN 50620:2017 Electric cables - Charging cables for electric vehicles
CEI 18-49 : 2013 ELECTRICAL INSTALLATIONS IN SHIPS - PART 350: GENERAL CONSTRUCTION AND TEST METHODS OF POWER, CONTROL AND INSTRUMENTATION CABLES FOR SHIPBOARD AND OFFSHORE APPLICATIONS
CEI EN 61375-3-1 : 2013 ELECTRONIC RAILWAY EQUIPMENT - TRAIN COMMUNICATION NETWORK (TCN) - PART 3-1: MULTIFUNCTION VEHICLE BUS (MVB)
BS ISO/IEC/IEEE 80005-1:2012 Utility connections in port High Voltage Shore Connection (HVSC) Systems. General requirements
UNE-EN 50525-2-72:2012 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) -- Part 2-72: Cables for general applications - Flat divisible cables (cords) with thermoplastic PVC insulation
16/30337938 DC : 0 BS EN 80005-1 - UTILITY CONNECTIONS IN PORT - HIGH VOLTAGE SHORE CONNECTION (HVSC) SYSTEMS - PART 1: GENERAL REQUIREMENTS
IEC 63010-1:2017 Halogen-free thermoplastic insulated and sheathed flexible cables of rated voltages up to and including 300/300 V - Part 1: General requirements and cables
BS EN 50382-2 : 2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2: SINGLE CORE SILICONE RUBBER INSULATED CABLES FOR 120 DEGREES C OR 150 DEGREES C
BS EN 50525-3-41:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables with special fire performance. Single core non-sheathed cables with halogen-free crosslinked insulation, and low emission of smoke
PREN 50525-2-83 : DRAFT 2008 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-83: CABLES FOR GENERAL APPLICATIONS - MULTICORE CABLES WITH CROSSLINKED SILICONE RUBBER INSULATION
CEI EN 50525-2-51 : 2012 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-51: CABLES FOR GENERAL APPLICATIONS - OIL RESISTANT CONTROL CABLES WITH THERMOPLASTIC PVC INSULATION
16/30337092 DC BS EN 13378. Pasta processing plant. Pasta presses. Safety and hygiene requirements
15/30314469 DC : 0 BS EN 62548 ED.1 - PHOTOVOLTAIC (PV) ARRAYS - DESIGN REQUIREMENTS
09/30205454 DC : 0 BS EN 61375-3-1 - ELECTRONIC RAILWAY EQUIPMENT - TRAIN COMMUNICATION NETWORK - PART 3-1: MVB - MULTIPURPOSE VEHICLE BUS
UNE-EN 50525-3-11:2012 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 3-11: Cables with special fire performance - Flexible cables with halogen-free thermoplastic insulation, and low emission of smoke
CEI EN 50143 : 2012 CABLES FOR SIGNS AND LUMINOUS-DISCHARGE-TUBE INSTALLATIONS OPERATING FROM A NO-LOAD RATED OUTPUT VOLTAGE EXCEEDING 1000 V BUT NOT EXCEEDING 10000 V
BS EN 60695-1-10:2017 Fire hazard testing Guidance for assessing the fire hazard of electrotechnical products. General guidelines
08/30188796 DC : 0 BS EN 50525-2-41 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-41: CABLES FOR GENERAL APPLICATIONS - SINGLE CORE CABLES WITH CROSSLINKED SILICONE RUBBER INSULATION
BS EN 50143:2009 Cables for signs and luminous-discharge-tube installations operating from a no-load rated output voltage exceeding 1000 V but not exceeding 10000 V
10/30215871 DC : 0 BS EN 50441-4 - CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 4: CABLES UP TO 1200 MHZ - GRADE 4
I.S. HD 632:2016 POWER CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES ABOVE 36 KV (U[M] = 42 KV) UP TO 150 KV (U[M] = 170 KV)
06/30151267 DC : 0 BS ISO CD 10840 - PLASTICS - GUIDANCE FOR THE USE OF STANDARD FIRE TESTS
08/30188839 DC : 0 BS EN 50525-3-31 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3-31: CABLES WITH SPECIAL FIRE PERFORMANCE - SINGLE CORE NON-SHEATHED CABLES WITH HALOGEN-FREE THERMOPLASTIC INSULATION, AND LOW EMISSION OF SMOKE
17/30347740 DC : 0 BS EN 63075 - SUPERCONDUCTING AC POWER CABLES AND THEIR ACCESSORIES FOR RATED VOLTAGES FROM 6 KV TO 500 KV - TEST METHODS AND REQUIREMENTS
BS EN 50525-2-31:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables for general applications. Single core non-sheathed cables with thermoplastic PVC insulation
BS EN 50264-2-2:2008 Railway applications. Railway rolling stock power and control cables having special fire performance Cables with crosslinked elastomeric insulation. Multicore cables
14/30289997 DC : 0 BS EN 62893-1 - CHARGING CABLES FOR ELECTRIC VEHICLES - PART 1: GENERAL REQUIREMENTS
10/30185766 DC : 0 BS EN 1889-1 - MACHINES FOR UNDERGROUND MINES - MOBILE MACHINES WORKING UNDERGROUND - SAFETY - PART 1: RUBBER TYRED VEHICLES
10/30215867 DC : 0 BS EN 50441-2 - CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 2: SCREENED CABLES - GRADE 2
09/30196635 DC : 0 BS EN 60092-510 - ELECTRICAL INSTALLATIONS IN SHIPS - SPECIAL FEATURES - HIGH VOLTAGE SHORE CONNECTION SYSTEMS (HVSC-SYSTEMS)
CEI EN 60332-2-2 : 2006 TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 2-2: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE SMALL INSULATED WIRE OR CABLE - PROCEDURE FOR DIFFUSION FLAME
09/30166429 DC : 0 BS 8492 - TELECOMMUNICATIONS EQUIPMENT AND TELECOMMUNICATIONS CABLING - CODE OF PRACTICE FOR FIRE PERFORMANCE AND PROTECTION
08/30188842 DC : 0 BS EN 50525-3-41 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3-41: CABLES WITH SPECIAL FIRE PERFORMANCE - SINGLE CORE NON-SHEATHED CABLES WITH HALOGEN-FREE CROSS LINKED INSULATION, AND LOW EMISSION OF SMOKE
CSA C22.2 No. 61010.1 :2012 SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL, AND LABORATORY USE - PART 1: GENERAL REQUIREMENTS
BS EN 62368-1 : 2014 AUDIO/VIDEO, INFORMATION AND COMMUNICATION TECHNOLOGY EQUIPMENT - PART 1: SAFETY REQUIREMENTS
I.S. HD 22.9:2007 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 9: SINGLE CORE HALOGEN-FREE NON-SHEATHED CABLES FOR FIXED WIRING HAVING LOW EMISSION OF SMOKE
I.S. HD 603:2007 DISTRIBUTION CABLES OF RATED VOLTAGE 0,6/1 KV
CEI EN 50525-2-41 : 2012 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-41: CABLES FOR GENERAL APPLICATIONS - SINGLE CORE CABLES WITH CROSSLINKED SILICONE RUBBER INSULATION
S.R. HD 60364-4-42:2011 LOW VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-42: PROTECTION FOR SAFETY - PROTECTION AGAINST THERMAL EFFECTS
S.R. CLC/TS 50576:2016 ELECTRIC CABLES - EXTENDED APPLICATION OF TEST RESULTS FOR REACTION TO FIRE
NFC 32 102-16 : 2007 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 16: WATER RESISTANT POLYCHLOROPRENE OR EQUIVALENT SYNTHETIC ELASTOMER SHEATHED CABLES
I.S. EN 50618:2014 ELECTRIC CABLES FOR PHOTOVOLTAIC SYSTEMS
IEC TR 60092-370:2009 Electrical installations in ships - Part 370: Guidance on the selection of cables for telecommunication and data transfer including radio-frequency cables
BS EN 50575 : 2014 POWER, CONTROL AND COMMUNICATION CABLES - CABLES FOR GENERAL APPLICATIONS IN CONSTRUCTION WORKS SUBJECT TO REACTION TO FIRE REQUIREMENTS
I.S. EN 50620:2017 ELECTRIC CABLES - CHARGING CABLES FOR ELECTRIC VEHICLES
I.S. EN 50441-4:2012 CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 4: CABLES UP TO 1200 MHZ - GRADE 3
I.S. EN 50264-3-1:2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 3-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION WITH REDUCED DIMENSIONS - SINGLE CORE CABLES
IEEE 525-2007 IEEE Guide for the Design and Installation of Cable Systems in Substations
CEI EN 50525-2-72 : 2012 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-72: CABLES FOR GENERAL APPLICATIONS - FLAT DIVISIBLE CABLES (CORDS) WITH THERMOPLASTIC PVC INSULATION
ISO/IEC 14763-2:2012 Information technology Implementation and operation of customer premises cabling Part 2: Planning and installation
S.R. HD 60364-5-56:2010 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-56: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - SAFETY SERVICES
CEI EN 50441-2 : 2013 CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 2: SCREENED CABLES - GRADE 1
CEI EN 50525-3-11 : 2012 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-11: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE THERMOPLASTIC INSULATION, AND LOW EMISSION OF SMOKE
NFC 32 102-13 : 2007 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 13: HALOGEN-FREE FLEXIBLE CABLES HAVING LOW EMISSION OF SMOKE
NF EN 50143 : 2009 CABLES FOR SIGNS AND LUMINOUS-DISCHARGE-TUBE INSTALLATIONS OPERATING FROM A NO-LOAD RATED OUTPUT VOLTAGE EXCEEDING 1000 V BUT NOT EXCEEDING 10000 V
CSA C22.2 No. 61010.1 : 2012 : INC : UPD 1 :2015 SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL, AND LABORATORY USE - PART 1: GENERAL REQUIREMENTS
IEC 62821-1:2015 Electric cables - Halogen-free, low smoke, thermoplastic insulated and sheathed cables of rated voltages up to and including 450/750 V - Part 1: General requirements
AAMI ES60601-1 : 2005 : INC : AMD 1 : 2012 : R201200 MEDICAL ELECTRICAL EQUIPMENT - PART 1: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE (IEC 60601-1:2005, MOD)
AAMI ES60601-1 : 2005 : INC : AMD 2 : 2012 : R201200 MEDICAL ELECTRICAL EQUIPMENT - PART 1: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE (IEC 60601-1:2005, MOD)
AAMI ES60601-1 : 2005 : R2012 MEDICAL ELECTRICAL EQUIPMENT - PART 1: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE (IEC 60601-1:2005, MOD)
CSA C22.2 No. 62368-1 : 2014 AUDIO/VIDEO, INFORMATION AND COMMUNICATION TECHNOLOGY EQUIPMENT - PART 1: SAFETY REQUIREMENTS
DIN EN 13378:2016-05 (Draft) PASTA PROCESSING PLANTS - PASTA PRESSES - SAFETY AND HYGIENE REQUIREMENTS
EN 60695-9-2:2014 Fire hazard testing - Part 9-2: Surface spread of flame - Summary and relevance of test methods
03/318326 DC : DRAFT NOV 2003
17/30338554 DC : 0 BS EN 1175 - SAFETY OF INDUSTRIAL TRUCKS - ELECTRICAL/ELECTRONIC REQUIREMENTS
BS EN 50174-2 : 2009 INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 2: INSTALLATION PLANNING AND PRACTICES INSIDE BUILDINGS
13/30238229 DC : 0 BS EN 62052-31 - ELECTRICITY METERING EQUIPMENT (AC) - GENERAL REQUIREMENTS, TEST AND TEST CONDITIONS - PART 31: PRODUCT SAFETY REQUIREMENTS
IEC 60332-1-1:2004+AMD1:2015 CSV Tests on electric and optical fibre cables under fire conditions - Part 1-1: Test for vertical flame propagation for a single insulatedwire or cable - Apparatus
BS EN 13378 : 2001 PASTA PROCESSING PLANTS - PASTA PRESSES - SAFETY AND HYGIENE REQUIREMENTS
DIN EN 12601:2011-07 RECIPROCATING INTERNAL COMBUSTION ENGINE DRIVEN GENERATING SETS - SAFETY
I.S. EN 13289:2001 PASTA PROCESSING PLANTS - DRYERS AND COOLERS - SAFETY AND HYGIENE REQUIREMENTS
EN 60695-1-10:2017 Fire hazard testing - Part 1-10: Guidance for assessing the fire hazard of electrotechnical products - General guidelines
IEC 62067:2011 RLV Power cables with extruded insulation and their accessories for rated voltages above 150 kV (<em>U</em><sub>m</sub> = 170 kV) up to 500 kV (<em>U</em><sub>m</sub> = 550 kV) - Test methods and requirements
EN 62052-31:2016 Electricity metering equipment (AC) - General requirements, tests and test conditions - Part 31: Product safety requirements and tests
EN 50264-2-1:2008 Railway applications - Railway rolling stock power and control cables having special fire performance - Part 2-1: Cables with crosslinked elastomeric insulation - Single core cables
EN 60332-1-3:2004/A1:2015 TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 1-3: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED WIRE OR CABLE - PROCEDURE FOR DETERMINATION OF FLAMING DROPLETS/PARTICLES (IEC 60332-1-3:2004/A1:2015)
EN 50525-2-51:2011 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-51: Cables for general applications - Oil resistant control cables with thermoplastic PVC insulation
HD 620 : 2010 DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV
EN 50525-2-31:2011 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-31: Cables for general applications - Single core non-sheathed cables with thermoplastic PVC insulation
EN 13379:2001+A1:2013 Pasta processing plants - Spreader, stripping and cutting machine, stick return conveyor, stick magazine - Safety and hygiene requirements
EN 50575:2014/A1:2016 POWER, CONTROL AND COMMUNICATION CABLES - CABLES FOR GENERAL APPLICATIONS IN CONSTRUCTION WORKS SUBJECT TO REACTION TO FIRE REQUIREMENTS
IEC 60695-1-10:2016 RLV Fire hazard testing - Part 1-10: Guidance for assessing the fire hazard of electrotechnical products - General guidelines
EN 50441-4:2012 Cables for indoor residential telecommunication installations - Part 4: Cables up to 1 200 MHz - Grade 3
HD 603 S1:1994/A3:2007 DISTRIBUTION CABLES OF RATED VOLTAGE 0,6/1 KV
EN 50525-2-72:2011 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-72: Cables for general applications - Flat divisible cables (cords) with thermoplastic PVC insulation
EN 50525-3-11:2011 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 3-11: Cables with special fire performance - Flexible cables with halogen-free thermoplastic insulation, and low emission of smoke
EN 50441-1:2012 Cables for indoor residential telecommunication installations - Part 1: Unscreened cables - Grade 1
HD 60364-7-717:2010/AC:2014 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 7-717: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - MOBILE OR TRANSPORTABLE UNITS
EN 12601:2010 Reciprocating internal combustion engine driven generating sets - Safety
EN 50525-2-81:2011 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-81: Cables for general applications - Cables with crosslinked elastomeric covering for arc welding
EN 13378:2001+A1:2013 Pasta processing plants - Pasta presses - Safety and hygiene requirements
EN 60702-1:2002/A1:2015 MINERAL INSULATED CABLES AND THEIR TERMINATIONS WITH A RATED VOLTAGE NOT EXCEEDING 750 V - PART 1: CABLES (IEC 60702-1:2002/A1:2015)
HD 60364-4-42 : 2011 AMD 1 2015 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-42: PROTECTION FOR SAFETY - PROTECTION AGAINST THERMAL EFFECTS (IEC 60364-4-42:2010/A1:2014)
CEI 18-64 : 2008 MOBILE AND FIXED OFFSHORE UNITS - ELECTRICAL INSTALLATIONS - PART 4: CABLES
EN 50382-1 : 2008 AMD 1 2013 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS
EN 50264-1:2008 Railway applications - Railway rolling stock power and control cables having special fire performance - Part 1: General requirements
EN 50525-2-71:2011 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-71: Cables for general applications - Flat tinsel cables (cords) with thermoplastic PVC insulation
EN 50525-3-31:2011 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 3-31: Cables with special fire performance - Single core non-sheathed cables with halogen-free thermoplastic insulation, and low emission of smoke
HD 22.13 : 200S2 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 13: HALOGEN-FREE FLEXIBLE CABLES HAVING LOW EMISSION OF SMOKE
HD 60364-5-52:2011/A11:2017 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-52: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - WIRING SYSTEMS
EN 50264-3-2:2008 Railway applications - Railway rolling stock power and control cables having special fire performance - Part 3-2: Cables with crosslinked elastomeric insulation with reduced dimensions - Multicore cables
EN 13289:2001+A1:2013 Pasta processing plants - Dryers and coolers - Safety and hygiene requirements
EN 60332-2-2:2004 Tests on electric and optical fibre cables under fire conditions - Part 2-2: Test for vertical flame propagation for a single small insulated wire or cable - Procedure for diffusion flame
HD 22.12 : 200S2 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 12: HEAT RESISTANT EPR CORDS AND FLEXIBLE CABLES
HD 22.16 : 200S2 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 16: WATER RESISTANT POLYCHLOROPRENE OR EQUIVALENT SYNTHETIC ELASTOMER SHEATHED CABLES
HD 60364-5-559:2012/A11:2017 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-559: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - LUMINAIRES AND LIGHTING INSTALLATIONS
CEI EN 50525-2-71 : 2012 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-71: CABLES FOR GENERAL APPLICATIONS - FLAT TINSEL CABLES (CORDS) WITH THERMOPLASTIC PVC INSULATION
BS IEC 62895:2017 High voltage direct current (HVDC) power transmission. Cables with extruded insulation and their accessories for rated voltages up to 320 kV for land applications. Test methods and requirements
BS EN 50441-4:2012 Cables for indoor residential telecommunication installations Cables up to 1 200 MHz. Grade 3
14/30290103 DC : 0 BS EN 62895 - HIGH VOLTAGE DIRECT CURRENT (HVDC) POWER TRANSMISSION CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES UP TO 320KV FOR LAND APPLICATIONS - TEST METHODS AND REQUIREMENTS
BS EN 50525-2-11:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750V (U0/U) Cables for general applications. Flexible cables with thermoplastic PVC insulation
08/30188821 DC : 0 BS EN 50525-2-82 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-82: CABLES FOR GENERAL APPLICATIONS - CABLES WITH CROSS LINKED ELASTOMERIC INSULATION FOR DECORATIVE CHAINS
I.S. EN 60702-1:2002 MINERAL INSULATED CABLES AND THEIR TERMINATIONS WITH A RATED VOLTAGE NOT EXCEEDING 750 V - PART 1: CABLES
I.S. EN 50575:2014 POWER, CONTROL AND COMMUNICATION CABLES - CABLES FOR GENERAL APPLICATIONS IN CONSTRUCTION WORKS SUBJECT TO REACTION TO FIRE REQUIREMENTS
17/30361394 DC : 0 BS EN 50174-1 - INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 1: INSTALLATION SPECIFICATION AND QUALITY ASSURANCE
I.S. EN 50525-2-81:2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-81: CABLES FOR GENERAL APPLICATIONS - CABLES WITH CROSSLINKED ELASTOMERIC COVERING FOR ARC WELDING
UNE-EN 50264-3-2:2010 Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 3-2: Cables with crosslinked elastomeric insulation with reduced dimensions - Multicore cables
08/30188793 DC : 0 BS EN 50525-2-31 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-31: CABLES FOR GENERAL APPLICATIONS - SINGLE CORE NON-SHEATHED CABLES WITH THERMOPLASTIC PVC INSULATION
BS EN 50525-3-31:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables with special fire performance. Single core non-sheathed cables with halogen-free thermoplastic insulation, and low emission of smoke
08/30159870 DC : DRAFT APR 2008 BS EN 60800 - HEATING CABLES WITH A RATED VOLTAGE OF 300/500 V FOR COMFORT HEATING AND PREVENTION OF ICE FORMATION
BS EN 60332-1-1 : 2004 TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 1-1: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED WIRE OR CABLE - APPARATUS
BS EN 50525-3-11:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables with special fire performance. Flexible cables with halogen-free thermoplastic insulation, and low emission of smoke
BS EN 60332-2-2:2004 Tests on electric and optical fibre cables under fire conditions Tests for vertical flame propagation for a single small insulated wire or cable. Procedure for diffusion flame
BS ISO 10840:2008 Plastics. Guidance for the use of standard fire tests
PREN 1889-1 : DRAFT 2010 MACHINES FOR UNDERGROUND MINES - MOBILE MACHINES WORKING UNDERGROUND - SAFETY - PART 1: RUBBER TYRED VEHICLES
08/30188818 DC : 0 BS EN 50525-2-81 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-81: CABLES FOR GENERAL APPLICATIONS - CABLES WITH CROSS LINKED ELASTOMERIC COVERING FOR ARC WELDING
BS EN 50441-1:2012 Cables for indoor residential telecommunication installations Unscreened cables. Grade 1
EN 50620:2017 Electric cables - Charging cables for electric vehicles
BS EN 50264-2-1:2008 Railway applications. Railway rolling stock power and control cables having special fire performance Cables with crosslinked elastomeric insulation. Single core cables
16/30329824 DC : 0 BS EN 60364-7-721 ED 2.0 - LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 7-721: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - ELECTRICAL INSTALLATIONS IN CARAVANS AND MOTOR CARAVANS
IEC PAS 60092-510:2009 Electrical installations in ships - Part 510: Special features - High-voltage shore connection systems
CEI EN 50525-2-81 : 2012 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-81: CABLES FOR GENERAL APPLICATIONS - CABLES WITH CROSSLINKED ELASTOMERIC COVERING FOR ARC WELDING
BS EN 50525-2-82:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables for general applications. Cables with crosslinked elastomeric insulation for decorative chains
PREN 50525-2-72 : DRAFT 2008 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-72: CABLES FOR GENERAL APPLICATIONS - FLAT DIVISIBLE CABLES (CORDS) WITH THERMOPLASTIC PVC INSULATION
10/30211242 DC : 0 BS EN 12601 - RECIPROCATING INTERNAL COMBUSTION ENGINE DRIVEN GENERATING SETS - SAFETY
CEI EN 50525-3-31 : 2012 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-31: CABLES WITH SPECIAL FIRE PERFORMANCE - SINGLE CORE NON-SHEATHED CABLES WITH HALOGEN-FREE THERMOPLASTIC INSULATION, AND LOW EMISSION OF SMOKE
08/30188833 DC : 0 BS EN 50525-3-11 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3-11: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE THERMOPLASTIC INSULATION, AND LOW EMISSION OF SMOKE
I.S. HD 60364-5-559:2012 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-559: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - LUMINAIRES AND LIGHTING INSTALLATIONS (IEC 60364-5-55:2011 (MOD))
03/305959 DC : DRAFT MAY 2003 EN 60332-1-3 ED. 1 - TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 1-3: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED WIRE OR CABLE - PROCEDURE FOR DETERMINATION OF FLAMING DROPLETS/ PARTICLES
NF EN 50396 : 2005 AMD 1 2012 NON ELECTRICAL TEST METHODS FOR LOW VOLTAGE ENERGY CABLES
I.S. HD 60364-4-42:2011 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-42: PROTECTION FOR SAFETY - PROTECTION AGAINST THERMAL EFFECTS
IEC PAS 80005-3:2014 Utility connections in port - Part 3: Low Voltage Shore Connection (LVSC) Systems - General requirements
EN 50174-2 : 2009 AMD 2 2014 INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 2: INSTALLATION PLANNING AND PRACTICES INSIDE BUILDINGS
NF EN 50214 : 2007 FLAT POLYVINYL CHLORIDE SHEATHED FLEXIBLE CABLES
IEC 62893-3:2017 Charging cables for electric vehicles for rated voltages up to and including 0,6/1 kV - Part 3: Cables for AC charging according to modes 1, 2 and 3 of IEC 61851-1 of rated voltages up to and including 450/750 V
PREN 50441-4 : DRAFT 2010 CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 4: CABLES UP TO 1200 MHZ - GRADE 4
I.S. EN 50174-2:2009 INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 2: INSTALLATION PLANNING AND PRACTICES INSIDE BUILDINGS
UNE-IEC 60092-306:2010 Electrical installations in ships - Part 306: Equipment - Luminaires and lighting accessories
CSA C22.2 No. 61010.1 : 2012 : FR SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL, AND LABORATORY USE - PART 1: GENERAL REQUIREMENTS
CEI CLC/TS 50576 : 2015 ELECTRIC CABLES - EXTENDED APPLICATION OF TEST RESULTS FOR REACTION TO FIRE
UNE-IEC 60092-350:2015 Electrical installations in ships - Part 350: General construction and test methods of power, control and instrumentation cables for shipboard and offshore applications
I.S. EN 50525-3-31:2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-31: CABLES WITH SPECIAL FIRE PERFORMANCE - SINGLE CORE NON-SHEATHED CABLES WITH HALOGEN-FREE THERMOPLASTIC INSULATION, AND LOW EMISSION OF SMOKE
I.S. EN 50264-3-2:2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 3-2: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION WITH REDUCED DIMENSIONS - MULTICORE CABLES
UNE-EN 50525-2-71:2012 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) -- Part 2-71: Cables for general applications - Flat tinsel cables (cords) with thermoplastic PVC insulation
CEI EN 50620 : 1ED 2017 ELECTRIC CABLES - CHARGING CABLES FOR ELECTRIC VEHICLES
I.S. EN 50525-2-11:2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-11: CABLES FOR GENERAL APPLICATIONS - FLEXIBLE CABLES WITH THERMOPLASTIC PVC INSULATION
UNE-EN 60332-2-2:2005 Tests on electric and optical fibre cables under fire conditions -- Part 2-2: Test for vertical flame propagation for a single small insulated wire or cable - Procedure for diffusion flame
CEI EN 50174-3 : 2014 INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 3: INSTALLATION PLANNING AND PRACTICES OUTSIDE BUILDINGS
CSA C22.2 No. 61010.1 : 2012 : INC : UPD 1 : 2015 SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL, AND LABORATORY USE - PART 1: GENERAL REQUIREMENTS
PREN 12601 : DRAFT 2010 RECIPROCATING INTERNAL COMBUSTION ENGINE DRIVEN GENERATING SETS - SAFETY
I.S. HD 60364-7-721:2009 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 7-721: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - ELECTRICAL INSTALLATIONS IN CARAVANS AND MOTOR CARAVANS
NF EN 61010-1 : 2011 SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL AND LABORATORY USE - PART 1: GENERAL REQUIREMENTS
I.S. EN 50264-2-1:2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION - SINGLE CORE CABLES
BS EN 50174-1 : 2009 INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 1: INSTALLATION SPECIFICATION AND QUALITY ASSURANCE
UNE-CLC/TS 50576:2017 Electric cables - Extended application of test results for reaction to fire
NF EN 50174-2 : 2009 AMD 1 2011 INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 2: INSTALLATION PLANNING AND PRACTICES INSIDE BUILDINGS
NF EN 50264-3-1 : 2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 3-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION WITH REDUCED DIMENSIONS - SINGLE CORE CABLES
IEC 60800:2009 Heating cables with a rated voltage of 300/500 V for comfort heating and prevention of ice formation
UNE-EN 50525-3-21:2012 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 3-21: Cables with special fire performance - Flexible cables with halogen-free crosslinked insulation, and low emission of smoke
PREN 50525-2-41 : DRAFT 2008 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-41: CABLES FOR GENERAL APPLICATIONS - SINGLE CORE CABLES WITH CROSSLINKED SILICONE RUBBER INSULATION
UNE-EN 50525-2-81:2012 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 2-81: Cables for general applications - Cables with crosslinked elastomeric covering for arc welding
PREN 50575 : DRAFT 2012 POWER, CONTROL AND COMMUNICATION CABLES - CABLES FOR GENERAL APPLICATIONS IN CONSTRUCTION WORKS SUBJECT TO REACTION TO FIRE REQUIREMENTS
PREN 50525-2-11 : DRAFT 2008 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-11: CABLES FOR GENERAL APPLICATIONS - FLEXIBLE CABLES WITH THERMOPLASTIC PVC INSULATION
S.R. CEN/TS 45545-2:2009 RAILWAY APPLICATIONS - FIRE PROTECTION ON RAILWAY VEHICLES - PART 2: REQUIREMENTS FOR FIRE BEHAVIOUR OF MATERIALS AND COMPONENTS
IEC 60840:2011 RLV Power cables with extruded insulation and their accessories for rated voltages above 30 kV (<em>U</em><sub>m</sub> = 36 kV) up to 150 kV (<em>U</em><sub>m</sub> = 170 kV) - Test methods and requirements
IEC 60364-5-55:2011+AMD1:2012+AMD2:2016 CSV Electrical installations of buildings - Part 5-55: Selection and erection of electrical equipment - Other equipment
IEC 62930:2017 Electric cables for photovoltaic systems with a voltage rating of 1,5 kV DC
IEC 60092-354:2014 Electrical installations in ships - Part 354: Single- and three-core power cables with extruded solid insulation for rated voltages 6 kV (U<sub>m</sub> = 7,2 kV) up to 30 kV (U<sub>m</sub> = 36 kV)
EN 61010-1:2010 Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements
AAMI ES60601-1 : 2005 MEDICAL ELECTRICAL EQUIPMENT - PART 1: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE (IEC 60601-1:2005, MOD)
IEC 60092-353:2016 Electrical installations in ships - Part 353: Power cables for rated voltages 1 kV and 3 kV
IEC 60227-5:2011 Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 5: Flexible cables (cords)
IEC 60364-7-712:2017 Low voltage electrical installations - Part 7-712: Requirements for special installations or locations - Solar photovoltaic (PV) power supply systems
I.S. EN 60695-9-2:2014 FIRE HAZARD TESTING - PART 9-2: SURFACE SPREAD OF FLAME - SUMMARY AND RELEVANCE OF TEST METHODS
DIN EN 13379:2016-06 (Draft) PASTA PROCESSING PLANTS - SPREADER, STRIPPING AND CUTTING MACHINE, STICK RETURN CONVEYOR, STICK MAGAZINE - SAFETY AND HYGIENE REQUIREMENTS
IEC 60092-376:2017 RLV Electrical installations in ships - Part 376: Cables for control and instrumentation circuits 150/250 V (300 V)
UNE-HD 60364-5-56:2010 Low-voltage electrical installations - Part 5-56: Selection and erection of electrical equipment - Safety services
PD IEC/TR 62222:2012 Fire performance of communication cables installed in buildings
BS EN 13379 : 2001 PASTA PROCESSING PLANTS - SPREADER, STRIPPING AND CUTTING MACHINE, STICK RETURN CONVEYOR, STICK MAGAZINE - SAFETY AND HYGIENE REQUIREMENTS
BS EN 12601:2010 Reciprocating internal combustion engine driven generating sets. Safety
I.S. EN 13379:2001 PASTA PROCESSING PLANTS - SPREADER, STRIPPING AND CUTTING MACHINE, STICK RETURN CONVEYOR, STICK MAGAZINE - SAFETY AND HYGIENE REQUIREMENTS
I.S. EN 13378:2001 PASTA PROCESSING PLANTS - PASTA PRESSES - SAFETY AND HYGIENE REQUIREMENTS
I.S. EN 1889-1:2011 MACHINES FOR UNDERGROUND MINES - MOBILE MACHINES WORKING UNDERGROUND - SAFETY - PART 1: RUBBER TYRED VEHICLES
DIN EN 13289:2013-05 PASTA PROCESSING PLANTS - DRYERS AND COOLERS - SAFETY AND HYGIENE REQUIREMENTS
EN 60079-14:2014/AC:2016 EXPLOSIVE ATMOSPHERES - PART 14: ELECTRICAL INSTALLATIONS DESIGN, SELECTION AND ERECTION (IEC 60079-14:2013/COR1:2016)
DIN EN 13378:2013-05 PASTA PROCESSING PLANTS - PASTA PRESSES - SAFETY AND HYGIENE REQUIREMENTS
DIN EN 13379:2013-05 PASTA PROCESSING PLANTS - SPREADER, STRIPPING AND CUTTING MACHINE, STICK RETURN CONVEYOR, STICK MAGAZINE - SAFETY AND HYGIENE REQUIREMENTS
I.S. EN 60079-35-1:2011 EXPLOSIVE ATMOSPHERES - PART 35-1: CAPLIGHTS FOR USE IN MINES SUSCEPTIBLE TO FIREDAMP - GENERAL REQUIREMENTS - CONSTRUCTION AND TESTING IN RELATION TO THE RISK OF EXPLOSION
PREN 50441-2 : DRAFT 2010 CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 2: SCREENED CABLES - GRADE 2
12/30273098 DC : 0 BS EN 60702-1:2002+A1 - MINERAL INSULATED CABLES AND THEIR TERMINATIONS WITH A RATED VOLTAGE NOT EXCEEDING 750 V - PART 1: CABLES
17/30347375 DC : 0 BS EN 62368-1 ED 3.0 - AUDIO/VIDEO; INFORMATION AND COMMUNICATION TECHNOLOGY EQUIPMENT - PART 1: SAFETY REQUIREMENTS
16/30336629 DC : 0 BS 8492 - TELECOMMUNICATIONS EQUIPMENT AND TELECOMMUNICATIONS CABLING - CODE OF PRACTICE FOR FIRE PERFORMANCE AND PROTECTION
08/30186163 DC : DRAFT JULY 2008 BS IEC 60092-306 - ELECTRICAL INSTALLATIONS IN SHIPS - PART 306: EQUIPMENT - LUMINAIRES AND LIGHTING ACCESSORIES
PREN 50525-3-11 : DRAFT 2008 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3-11: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE THERMOPLASTIC INSULATION, AND LOW EMISSION OF SMOKE
10/30216687 DC : 0 BS EN 45545-2 - RAILWAY APPLICATIONS - FIRE PROTECTION ON RAILWAY VEHICLES - PART 2: REQUIREMENTS FOR FIRE BEHAVIOUR OF MATERIALS AND COMPONENTS
UNE-EN 50618:2015 Electric cables for photovoltaic systems
BS EN 50382-1 : 2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS
UNE-EN 50525-2-83:2012 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 2-83: Cables for general applications - Multicore cables with crosslinked silicone rubber insulation
BS IEC 60092-306:2009 Electrical installations in ships Equipment. Luminaires and lighting accessories
16/30326336 DC : 0 BS EN 63010-1 - ELECTRIC CABLES - HALOGEN-FREE THERMOPLASTIC INSULATED AND SHEATHED FLEXIBLE CABLES OF RATED VOLTAGES UP TO AND INCLUDING 300/300 V - PART 1: GENERAL REQUIREMENTS
BS EN 50264-1:2008 Railway applications. Railway rolling stock power and control cables having special fire performance General requirements
17/30348256 DC : 0 BS EN 13501-6 - FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 6: CLASSIFICATION USING DATA FROM REACTION TO FIRE TESTS ON ELECTRIC CABLES
NFC 32 102-12 : 2007 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 12: HEAT RESISTANT EPR CORDS AND FLEXIBLE CABLES
12/30260552 DC : 0 BS EN 50174-3:201X - INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 3: INSTALLATION PLANNING AND PRACTICES OUTSIDE BUILDINGS
03/305961 DC : DRAFT MAY 2003 EN 60332-2-2 ED. 1 - TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 2-2: TEST FOR A VERTICAL FLAME PROPAGATION FOR A SINGLE SMALL VERTICAL INSULATED WIRE OR CABLE - PROCEDURE FOR DIFFUSION FLAME
10/30215863 DC : 0 BS EN 50441-1 - CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 1: UNSCREENED CABLES - GRADE 1
BS EN 50525-2-81:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables for general applications. Cables with crosslinked elastomeric covering for arc welding
CEI EN 50264-2-1 : 2009 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION - SINGLE CORE CABLES
CEI EN 50525-3-41 : 2012 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-41: CABLES WITH SPECIAL FIRE PERFORMANCE - SINGLE CORE NON-SHEATHED CABLES WITH HALOGEN-FREE CROSSLINKED INSULATION, AND LOW EMISSION OF SMOKE
CEI EN 50525-2-11 : 2012 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-11: CABLES FOR GENERAL APPLICATIONS - FLEXIBLE CABLES WITH THERMOPLASTIC PVC INSULATION
BS EN 50264-3-2:2008 Railway applications. Railway rolling stock power and control cables having special fire performance Cables with crosslinked elastomeric insulation with reduced dimensions. Multicore cables
08/30188771 DC : 0 BS EN 50525-2-11 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-11: CABLES FOR GENERAL APPLICATIONS - FLEXIBLE CABLES WITH THERMOPLASTIC PVC INSULATION
I.S. EN 50214:2007 FLAT POLYVINYL CHLORIDE SHEATHED FLEXIBLE CABLES
BS EN 50441-2:2012 Cables for indoor residential telecommunication installations Screened cables. Grade 1
BS EN 61375-3-1:2012 Electronic railway equipment. Train communication network (TCN) Multifunction Vehicle Bus (MVB)
BS EN 50525-2-83:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables for general applications. Multicore cables with crosslinked silicone rubber insulation
UNE-IEC 60092-353:2017 Electrical installations in ships - Part 353: Power cables for rated voltages 1 kV and 3 kV
CEI EN 50264-2-2 : 2009 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-2: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION - MULTICORE CABLES
UNE-EN 50264-2-1:2010 Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 2-1: Cables with crosslinked elastomeric insulation - Single core cables
IEC 60364-5-52:2009 Low-voltage electrical installations - Part 5-52: Selection and erection of electrical equipment - Wiring systems
IEC 62821-3:2015 Electric cables - Halogen-free, low smoke, thermoplastic insulated and sheathed cables of rated voltages up to and including 450/750 V - Part 3: Flexible cables (cords)
NFC 32 102-9 : 2007 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 9: SINGLE CORE HALOGEN-FREE NON-SHEATHED CABLES FOR FIXED WIRING HAVING LOW EMISSION OF SMOKE
IEC 61892-3:2012 Mobile and fixed offshore units - Electrical installations - Part 3: Equipment
UNE-EN 60332-1-1:2005 Tests on electric and optical fibre cables under fire conditions -- Part 1-1: Test for vertical flame propagation for a single insulated wire or cable - Apparatus
UNE-EN 50525-2-11:2012 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 2-11: Cables for general applications - Flexible cables with thermoplastic PVC insulation
I.S. EN 50174-1:2009 INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 1: INSTALLATION SPECIFICATION AND QUALITY ASSURANCE
I.S. HD 60364-5-56:2010 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-56: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - SAFETY SERVICES (IEC 60364-5-56:2009 (EQV))
I.S. EN 50441-2:2012 CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 2: SCREENED CABLES - GRADE 1
I.S. HD 60364-5-52:2011 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-52: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - WIRING SYSTEMS
BS EN 13501-6:2014 Fire classification of construction products and building elements Classification using data from reaction to fire tests on electric cables
PREN 50525-2-71 : DRAFT 2008 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-71: CABLES FOR GENERAL APPLICATIONS - FLAT TINSEL CABLES (CORDS) WITH THERMOPLASTIC PVC INSULATION
BS EN 60702-1 : 2002 MINERAL INSULATED CABLES AND THEIR TERMINATIONS WITH A RATED VOLTAGE NOT EXCEEDING 750 V - PART 1: CABLES
CEI EN 50525-2-83 : 2012 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-83: CABLES FOR GENERAL APPLICATIONS - MULTICORE CABLES WITH CROSSLINKED SILICONE RUBBER INSULATION
I.S. EN 60601-1:2006&A1:2013&AC:2014&A12:2014 MEDICAL ELECTRICAL EQUIPMENT - PART 1: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE
PREN 13501-6 : DRAFT 2017 FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 6: CLASSIFICATION USING DATA FROM REACTION TO FIRE TESTS ON ELECTRIC CABLES
I.S. EN 50264-1:2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS
I.S. EN 50174-3:2013 INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 3: INSTALLATION PLANNING AND PRACTICES OUTSIDE BUILDINGS
IEC 61892-5:2014 Mobile and fixed offshore units - Electrical installations - Part 5: Mobile units
UNI EN 13501-6 : 2014 FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 6: CLASSIFICATION USING DATA FROM REACTION TO FIRE TESTS ON ELECTRIC CABLES
CEI EN 50264-3-2 : 2009 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 3-2: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION WITH REDUCED DIMENSIONS - MULTICORE CABLES
I.S. EN 13501-6:2014 FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 6: CLASSIFICATION USING DATA FROM REACTION TO FIRE TESTS ON ELECTRIC CABLES
CEI EN 50441-1 : 2013 CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 1: UNSCREENED CABLES - GRADE 1
PD IEC/TR 60601-4-3:2015 Medical electrical equipment Guidance and interpretation. Considerations of unaddressed safety aspects in the third edition of IEC 60601-1 and proposals for new requirements
PREN 50174-3 : DRAFT 2012 INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 3: INSTALLATION PLANNING AND PRACTICES OUTSIDE BUILDINGS
PREN 50441-1 : DRAFT 2010 CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 1: UNSCREENED CABLES - GRADE 1
NF EN 50382-2 : 2008 AMD 1 2013 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2: SINGLE CORE SILICONE RUBBER INSULATED CABLES FOR 120 DEGREES C OR 150 DEGREES C
CAN/CSA-C22.2 NO. 61010-1-12 (R2017) Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements (Tri-national standard, with UL 61010-1 and ANSI/ISA-61010-1 (82.02.01)
EN 13501-6:2014 Fire classification of construction products and building elements - Part 6: Classification using data from reaction to fire tests on electric cables
IEC 62368-1:2014 Audio/video, information and communication technology equipment - Part 1: Safety requirements
IEC 61196-4:2015 Coaxial communication cables - Part 4: Sectional specification for radiating cables
DIN EN 1710:2008-08 EQUIPMENT AND COMPONENTS INTENDED FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES IN UNDERGROUND MINES
UNE-EN 60695-9-2:2014 Fire hazard testing - Part 9-2: Surface spread of flame - Summary and relevance of test methods
IEC TS 60695-9-2:2005 Fire hazard testing - Part 9-2: Surface spread of flame - Summary and relevance of test methods
UNE-EN 60079-14:2016 Explosive atmospheres - Part 14: Electrical installations design, selection and erection
UNE-EN 1889-1:2012 Machines for underground mines - Mobile machines working underground - Safety - Part 1: Rubber tyred vehicles
IEC 60695-9-2:2014 Fire hazard testing - Part 9-2: Surface spread of flame - Summary and relevance of test methods
ISO/TR 10093:2017 Plastics Fire tests Standard ignition sources
DIN EN 1889-1:2011-10 MACHINES FOR UNDERGROUND MINES - MOBILE MACHINES WORKING UNDERGROUND - SAFETY - PART 1: RUBBER TYRED VEHICLES
BS EN 60079-14:2014 Explosive atmospheres Electrical installations design, selection and erection
UNE-EN 61010-1:2011 Safety requirements for electrical equipment for measurement, control and laboratory use -- Part 1: General requirements
ISA 61010-1 : 2008 SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL, AND LABORATORY USE - PART 1: GENERAL REQUIREMENTS
IEC 60092-353:2016 RLV Electrical installations in ships - Part 353: Power cables for rated voltages 1 kV and 3 kV
UNE-HD 620-10E:2012 Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV up to and including 20,8/36 (42) kV. Part 10: XLPE insulated single core and 3 core cables, and single core pre-assembled cables. Section E: Cables with polyolefine compound sheath (types 10E-1, 10E-3, 10E-4 and 10E-5).
UNE-HD 620-9E:2012 Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV up to and including 20,8/36 (42) kV. Part 9: HEPR insulated single core cables, and single core pre-assembled cables. Section E: Cables with polyolefine compound sheath (types 9E-1, 9E-3, 9E-4 and 9E-5).
UNI EN 13379 : 2013 PASTA PROCESSING PLANTS - SPREADER, STRIPPING AND CUTTING MACHINE, STICK RETURN CONVEYOR, STICK MAGAZINE - SAFETY AND HYGIENE REQUIREMENTS
UNI EN 1889-1 : 2011 MACHINES FOR UNDERGROUND MINES - MOBILE MACHINES WORKING UNDERGROUND - SAFETY - PART 1: RUBBER TYRED VEHICLES
UNI EN 13378 : 2013 PASTA PROCESSING PLANTS - PASTA PRESSES - SAFETY AND HYGIENE REQUIREMENTS
UNI EN 12601 : 2011 RECIPROCATING INTERNAL COMBUSTION ENGINE DRIVEN GENERATING SETS - SAFETY
UNI EN 13289 : 2013 PASTA PROCESSING PLANTS - DRYERS AND COOLERS - SAFETY AND HYGIENE REQUIREMENTS
UNI EN 1710 : 2008 EQUIPMENT AND COMPONENTS INTENDED FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES IN UNDERGROUND MINES
UNE-EN 50264-1:2010 Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 1: General requirements
I.S. EN 50441-1:2012 CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 1: UNSCREENED CABLES - GRADE 1
08/30188836 DC : 0 BS EN 50525-3-21 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3-21: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE CROSS LINKED INSULATION, AND LOW EMISSION OF SMOKE
08/30188826 DC : 0 BS EN 50525-2-83 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-83: CABLES FOR GENERAL APPLICATIONS - MULTICORE CABLES WITH CROSS LINKED SILICONE RUBBER INSULATION
I.S. EN 12601:2010 RECIPROCATING INTERNAL COMBUSTION ENGINE DRIVEN GENERATING SETS - SAFETY
12/30239867 DC : 0 BS EN 62368-1 - AUDIO/VIDEO, INFORMATION AND COMMUNICATION TECHNOLOGY EQUIPMENT - PART 1: SAFETY REQUIREMENTS
CEI EN 62368-1 : 2016 AUDIO/VIDEO, INFORMATION AND COMMUNICATION TECHNOLOGY EQUIPMENT - PART 1: SAFETY REQUIREMENTS
EA 0052:2014 Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV to 20,8/36 (42) kV. HPTR insulated single core cables and single core pre-assembled cables. Cables with polyolefine compound sheath (type 1, type 2 and type 3).
BS 8492:2009 Telecommunications equipment and telecommunications cabling. Code of practice for fire performance and protection
PREN 1175 : DRAFT 2017 SAFETY OF INDUSTRIAL TRUCKS - ELECTRICAL/ELECTRONIC REQUIREMENTS
I.S. EN 61010-1:2010/A1:2019 SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL AND LABORATORY USE - PART 1: GENERAL REQUIREMENTS
BS EN 50620:2017 Electric cables. Charging cables for electric vehicles (BT(DE/NOT)259)
BS EN 50525-2-41:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables for general applications. Single core cables with crosslinked silicone rubber insulation
BS EN 50525-3-21:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables with special fire performance. Flexible cables with halogen-free crosslinked insulation, and low emission of smoke
PD IEC/PAS 80005-3:2014 Utility connections in port Low Voltage Shore Connection (LVSC) Systems. General requirements
UNE-EN 50264-3-1:2010 Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 3-1: Cables with crosslinked elastomeric insulation with reduced dimensions - Single core cables
BS EN 50525-2-21:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables for general applications. Flexible cables with crosslinked elastomeric insulation
BS EN 60332-1-3 : 2004 TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 1-3: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED WIRE OR CABLE - PROCEDURE FOR DETERMINATION OF FLAMING DROPLETS/PARTICLES
PREN 50525-2-21 : DRAFT 2008 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-21: CABLES FOR GENERAL APPLICATIONS - FLEXIBLE CABLES WITH CROSSLINKED ELASTOMERIC INSULATION
CEI EN 50525-2-21 : 2012 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-21: CABLES FOR GENERAL APPLICATIONS - FLEXIBLE CABLES WITH CROSSLINKED ELASTOMERIC INSULATION
PREN 50525-2-31 : DRAFT 2008 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-31: CABLES FOR GENERAL APPLICATIONS - SINGLE CORE NON-SHEATHED CABLES WITH THERMOPLASTIC PVC INSULATION
PREN 50525-2-51 : DRAFT 2008 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-51: CABLES FOR GENERAL APPLICATIONS - OIL RESISTANT CONTROL CABLES WITH THERMOPLASTIC PVC INSULATION
IEC 60502-2:2014 RLV Power cables with extruded insulation and their accessories for rated voltages from 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) up to 30 kV (<em>U</em><sub>m</sub> = 36 kV) – Part 2: Cables for rated voltages from 6 kV (<em>U</em><sub>m</sub> = 7,2 kV) up to 30 kV (<em>U</em><sub>m</sub> = 36 kV)
BS EN 50264-3-1:2008 Railway applications. Railway rolling stock power and control cables having special fire performance Cables with crosslinked elastomeric insulation with reduced dimensions. Single core cables
PD CLC/TS 50576:2016 Electric cables - Extended application of test results for reaction to fire
BS EN 50214:2006 Flat polyvinyl chloride sheathed flexible cables
CEI EN 50264-3-1 : 2009 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 3-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION WITH REDUCED DIMENSIONS - SINGLE CORE CABLES
08/30188810 DC : 0 BS EN 50525-2-71 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-71: CABLES FOR GENERAL APPLICATIONS - FLAT TINSEL CABLES (CORDS) WITH THERMOPLASTIC PVC INSULATION
14/30313775 DC : 0 BS EN 62893-3 - CHARGING CABLES FOR ELECTRIC VEHICLES - PART 3: CABLES FOR AC CHARGING ACCORDING TO MODES 1, 2 AND 3 OF IEC 61851-1
BS EN 50525-2-51:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables for general applications. Oil resistant control cables with thermoplastic PVC insulation
12/30259025 DC : 0 BS EN 50575 - POWER, CONTROL AND COMMUNICATION CABLES - CABLES FOR GENERAL APPLICATIONS IN CONSTRUCTION WORKS SUBJECT TO REACTION TO FIRE REQUIREMENTS
UNI CEI CEN/TS 45545-2 : 2009 RAILWAY APPLICATIONS - FIRE PROTECTION OF RAILWAY VEHICLES - PART 2: REQUIREMENTS FOR FIRE BEHAVIOUR OF MATERIALS AND COMPONENTS
12/30258453 DC : 0 BS EN 62368-1 AMD - AUDIO/VIDEO, INFORMATION AND COMMUNICATION TECHNOLOGY EQUIPMENT - PART 1: SAFETY REQUIREMENTS
CEI EN 50264-1 : 2009 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS
PREN 50525-2-82 : DRAFT 2008 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-82: CABLES FOR GENERAL APPLICATIONS - CABLES WITH CROSSLINKED ELASTOMERIC INSULATION FOR DECORATIVE CHAINS
I.S. EN 50525-2-83:2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-83: CABLES FOR GENERAL APPLICATIONS - MULTICORE CABLES WITH CROSSLINKED SILICONE RUBBER INSULATION
IEC 60227-7:1995+AMD1:2003+AMD2:2011 CSV Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 7: Flexible cables screened and unscreened with two or more conductors
IEC 61892-4:2007 Mobile and fixed offshore units - Electrical installations - Part 4: Cables
IEC 60092-352:2005 Electrical installations in ships - Part 352: Choice and installation of electrical cables
DD CEN/TS 45545-2:2009 Railway applications. Fire protection on railway vehicles Requirements for fire behaviour of materials and components
I.S. EN 50525-3-21:2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-21: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE CROSSLINKED INSULATION, AND LOW EMISSION OF SMOKE
PREN 50174-1 : DRAFT 2017 INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 1: INSTALLATION SPECIFICATION AND QUALITY ASSURANCE
CEI EN 50525-3-21 : 2012 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-21: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE CROSSLINKED INSULATION, AND LOW EMISSION OF SMOKE
CSA C22.2 No. 61010.1 : 2012 : INC : UPD 2 :2016 SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL, AND LABORATORY USE - PART 1: GENERAL REQUIREMENTS
I.S. EN 50628:2016 ERECTION OF ELECTRICAL INSTALLATIONS IN UNDERGROUND MINES
I.S. EN 50382-2:2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2: SINGLE CORE SILICONE RUBBER INSULATED CABLES FOR 120 DEGREES C OR 150 DEGREES C
I.S. EN 50525-3-11:2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-11: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE THERMOPLASTIC INSULATION, AND LOW EMISSION OF SMOKE
I.S. EN 50525-2-72:2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-72: CABLES FOR GENERAL APPLICATIONS - FLAT DIVISIBLE CABLES (CORDS) WITH THERMOPLASTIC PVC INSULATION
NF EN 50264-2-2 : 2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-2: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION - MULTICORE CABLES
EN 50174-3:2013/A1:2017 INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 3: INSTALLATION PLANNING AND PRACTICES OUTSIDE BUILDINGS
PREN 13378 : DRAFT 2016 PASTA PROCESSING PLANTS - PASTA PRESSES - SAFETY AND HYGIENE REQUIREMENTS
I.S. EN 62368-1:2014 AUDIO/VIDEO, INFORMATION AND COMMUNICATION TECHNOLOGY EQUIPMENT - PART 1: SAFETY REQUIREMENTS (IEC 62368-1:2014, MODIFIED)
I.S. EN 50382-1:2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS
I.S. EN 60695-1-10:2017 FIRE HAZARD TESTING - PART 1-10: GUIDANCE FOR ASSESSING THE FIRE HAZARD OF ELECTROTECHNICAL PRODUCTS - GENERAL GUIDELINES
ISO 10840:2008 Plastics — Guidance for the use of standard fire tests
S.R. HD 60364-5-559:2012 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-559: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - LUMINAIRES AND LIGHTING INSTALLATIONS
NF EN 50618 : 2015 ELECTRIC CABLES FOR PHOTOVOLTAIC SYSTEMS
S.R. HD 60364-5-52:2011 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-52: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - WIRING SYSTEMS
UNE-IEC 60092-376:2017 Electrical installations in ships - Part 376: Cables for control and instrumentation circuits 150/250 V (300 V)
IEC 60092-306:2009 Electrical installations in ships - Part 306: Equipment - Luminaires and lighting accessories
EN 62368-1:2014/AC:2017-03 AUDIO/VIDEO, INFORMATION AND COMMUNICATION TECHNOLOGY EQUIPMENT - PART 1: SAFETY REQUIREMENTS (IEC 62368-1:2014, MODIFIED)
I.S. EN 50525-2-82:2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-82: CABLES FOR GENERAL APPLICATIONS - CABLES WITH CROSSLINKED ELASTOMERIC INSULATION FOR DECORATIVE CHAINS
NF EN 50174-1 : 2009 AMD 1 2011 INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 1: INSTALLATION SPECIFICATION AND QUALITY ASSURANCE
CEI EN 50441-4 : 2013 CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 4: CABLES UP TO 1200 MHZ - GRADE 3
CEI EN 50525-2-82 : 2012 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-82: CABLES FOR GENERAL APPLICATIONS - CABLES WITH CROSSLINKED ELASTOMERIC INSULATION FOR DECORATIVE CHAINS
IEC 60227-1:2007 Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 1: General requirements
I.S. EN 61010-1:2010 SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL AND LABORATORY USE - PART 1: GENERAL REQUIREMENTS
I.S. EN 50525-2-31:2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-31: CABLES FOR GENERAL APPLICATIONS - SINGLE CORE NON-SHEATHED CABLES WITH THERMOPLASTIC PVC INSULATION
IEC 60092-350:2014 Electrical installations in ships - Part 350: General construction and test methods of power, control and instrumentation cables for shipboard and offshore applications
I.S. HD 22.16:2007 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 16: WATER RESISTANT POLYCHLOROPRENE OR EQUIVALENT SYNTHETIC ELASTOMER SHEATHED CABLES
I.S. HD 620:2010 DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV
IEC 61196-11:2016 Coaxial communication cables - Part 11: Sectional specification for semi-rigid cables with polyethylene (PE) dielectric
I.S. EN 50525-3-41:2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-41: CABLES WITH SPECIAL FIRE PERFORMANCE - SINGLE CORE NON-SHEATHED CABLES WITH HALOGEN-FREE CROSSLINKED INSULATION, AND LOW EMISSION OF SMOKE
I.S. EN 50525-2-51:2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-51: CABLES FOR GENERAL APPLICATIONS - OIL RESISTANT CONTROL CABLES WITH THERMOPLASTIC PVC INSULATION
IEC 60364-7-721:2017 Low-voltage electrical installations - Part 7-721: Requirements for special installations or locations - Electrical installations in caravans and motor caravans
EN 50174-1:2009/A2:2014 INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 1: INSTALLATION SPECIFICATION AND QUALITY ASSURANCE
PD IEC/TS 62850:2013 Safety requirements for electrical equipment for measurement, control, and laboratory use. General requirements for equipment intended to be used in educational establishments by children
IEC 62052-31:2015 Electricity metering equipment (AC) - General requirements, tests and test conditions - Part 31: Product safety requirements and tests
BS EN 60601-1 : 2006 MEDICAL ELECTRICAL EQUIPMENT PART 1: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE
PD IEC/TS 62548:2013 Photovoltaic (PV) arrays. Design requirements
IEC 61375-3-1:2012 Electronic railway equipment - Train communication network (TCN) - Part 3-1: Multifunction Vehicle Bus (MVB)
UNE-EN 12601:2011 Reciprocating internal combustion engine driven generating sets - Safety
IEC TS 62850:2013 Safety requirements for electrical equipment for measurement, control, and laboratory use - General requirements for equipment intended to be used in educational establishments by children
DD IEC TS 60695-9-2 : DRAFT 2005 FIRE HAZARD TESTING - PART 9-2: SURFACE SPREAD OF FLAME - SUMMARY AND RELEVANCE OF TEST METHODS
IEC 60332-1-3:2004+AMD1:2015 CSV Tests on electric and optical fibre cables under fire conditions - Part 1-3: Test for vertical flame propagation for a single insulatedwire or cable - Procedure for determination of flamingdroplets/particles
05/30138005 DC : DRAFT AUG 2005 IEC 60079-14 ED 4 - ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES - PART 14: ELECTRICAL INSTALLATIONS IN HAZARDOUS AREAS (OTHER THAN MINES)
BS EN 13289 : 2001 PASTA PROCESSING PLANTS - DRYERS AND COOLERS - SAFETY AND HYGIENE REQUIREMENTS
BS EN 60695-9-2:2014 Fire hazard testing Surface spread of flame. Summary and relevance of test methods
17/30361391 DC : 0 BS EN 50174-2 - INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 2: INSTALLATION PLANNING AND PRACTICES INSIDE BUILDINGS
BS EN 60079-35-1:2011 Household and similar electrical appliances - Safety - Part 2-82: Particular requirements for amusement machines and personal service machines
UNE-EN 50525-2-41:2012 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) -- Part 2-41: Cables for general applications - Single core cables with crosslinked silicone rubber insulation
IEC 60702-1:2002+AMD1:2015 CSV Mineral insulated cables and their terminations with a rated voltage not exceeding 750 V - Part 1: Cables
IEC 60332-2-2:2004 Tests on electric and optical fibre cables under fire conditions - Part 2-2: Test for vertical flame propagation for a single small insulated wire or cable - Procedure for diffusion flame
UNE-EN 50525-2-31:2012 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) -- Part 2-31: Cables for general applications - Single core non-sheathed cables with thermoplastic PVC insulation
BS EN 1710 : 2005 EQUIPMENT AND COMPONENTS INTENDED FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES IN UNDERGROUND MINES
IEC TR 62222:2012 Fire performance of communication cables installed in buildings
10/30230568 DC : 0 BS EN 61892-3 - MOBILE AND FIXED OFFSHORE UNITS - ELECTRICAL INSTALLATIONS - PART 3: EQUIPMENT
IEC 60079-35-1:2011 Explosive atmospheres - Part 35-1: Caplights for use in mines susceptible to firedamp - General requirements - Construction and testing in relation to the risk of explosion
UNE-EN 50525-2-82:2012 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 2-82: Cables for general applications - Cables with crosslinked elastomeric insulation for decorative chains
UNE-IEC 61892-4:2016 Mobile and fixed offshore units - Electrical installations - Part 4: Cables
UNE-EN 60079-35-1:2012 Explosive atmospheres - Part 35-1: Caplights for use in mines susceptible to firedamp - General requirements - Construction and testing in relation to the risk of explosion
EN 50525-2-83:2011 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-83: Cables for general applications - Multicore cables with crosslinked silicone rubber insulation
EN 50525-2-41:2011 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-41: Cables for general applications - Single core cables with crosslinked silicone rubber insulation
EN 50441-2:2012 Cables for indoor residential telecommunication installations - Part 2: Screened cables - Grade 1
EN 1889-1:2011 Machines for underground mines - Mobile machines working underground - Safety - Part 1: Rubber tyred vehicles
PREN 50525-2-81 : DRAFT 2008 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-81: CABLES FOR GENERAL APPLICATIONS - CABLES WITH CROSSLINKED ELASTOMERIC COVERING FOR ARC WELDING
PREN 50525-3-41 : DRAFT 2008 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3-41: CABLES WITH SPECIAL FIRE PERFORMANCE - SINGLE CORE NON-SHEATHED CABLES WITH HALOGEN-FREE CROSSLINKED INSULATION, AND LOW EMISSION OF SMOKE
UNE-EN 60695-1-10:2017 Fire hazard testing - Part 1-10: Guidance for assessing the fire hazard of electrotechnical products - General guidelines
04/30114758 DC : 0 IEC 60092-350 ED.3 - ELECTRICAL INSTALLATION IN SHIP - PART 350: SHIPBOARD POWER CABLES - GENERAL CONSTRUCTION AND TEST REQUIREMENTS
07/30164212 DC : 0 BS EN 50143 - CABLES FOR SIGNS AND LUMINOUS-DISCHARGE TUBE INSTALLATIONS OPERATING FROM A NO-LOAD RATED OUTPUT VOLTAGE EXCEEDING 1000 V BUT NOT EXCEEDING 10000 V
I.S. HD 60364-7-717:2010 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 7-717: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - MOBILE OR TRANSPORTABLE UNITS
BS EN 50618:2014 Electric cables for photovoltaic systems (BT(DE/NOT)258)
UNE-EN 50525-3-41:2012 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 3-41: Cables with special fire performance - Single core non-sheathed cables with halogen-free crosslinked insulation, and low emission of smoke
BS EN 50525-2-71:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables for general applications. Flat tinsel cables (cords) with thermoplastic PVC insulation
08/30188783 DC : 0 BS EN 50525-2-21 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-21: CABLES FOR GENERAL APPLICATIONS - FLEXIBLE CABLES WITH CROSSLINKED ELASTOMERIC INSULATION
CEI EN 50214 : 2007 FLAT POLYVINYL CHLORIDE SHEATHED FLEXIBLE CABLES
09/30211785 DC : 0 BS ISO/IEC 14763-2 - INFORMATION TECHNOLOGY - IMPLEMENTATION AND OPERATION OF CUSTOMER PREMISES CABLING - PART 2: PLANNING AND INSTALLATION
BS EN 50525-2-72:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables for general applications. Flat divisible cables (cords) with thermoplastic PVC insulation
DIN EN 13501-6:2014-07 FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 6: CLASSIFICATION USING DATA FROM REACTION TO FIRE TESTS ON ELECTRIC CABLES
PREN 50525-3-31 : DRAFT 2008 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3-31: CABLES WITH SPECIAL FIRE PERFORMANCE - SINGLE CORE NON-SHEATHED CABLES WITH HALOGEN-FREE THERMOPLASTIC INSULATION, AND LOW EMISSION OF SMOKE
08/30188813 DC : 0 BS EN 50525-2-72 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-72: CABLES FOR GENERAL APPLICATIONS - FLAT DIVISIBLE CABLES (CORDS) WITH THERMOPLASTIC PVC INSULATION
I.S. EN 50264-2-2:2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-2: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION - MULTICORE CABLES
NFC 32 201-15 : 2006 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING THERMOPLASTIC INSULATION - PART 15: SINGLE CORE CABLES, INSULATED WITH HALOGEN-FREE THERMOPLASTIC COMPOUND, FOR FIXED WIRING
UNE-EN 50575:2015 Power, control and communication cables - Cables for general applications in construction works subject to reaction to fire requirements
I.S. EN 60079-14:2014 EXPLOSIVE ATMOSPHERES - PART 14: ELECTRICAL INSTALLATIONS DESIGN, SELECTION AND ERECTION
BS IEC 61892-3:2012 Mobile and fixed offshore units. Electrical installations Equipment
HD 60364-5-56:2010/A12:2017 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-56: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - SAFETY SERVICES
NF EN 50382-1 : 2008 AMD 1 2013 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS
HD 60364-7-721:2009/corrigendum:2010 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 7-721: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - ELECTRICAL INSTALLATIONS IN CARAVANS AND MOTOR CARAVANS
08/30188804 DC : 0 BS EN 50525-2-51 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-51: CABLES FOR GENERAL APPLICATIONS - OIL RESISTANT CONTROL CABLES WITH THERMOPLASTIC PVC INSULATION
I.S. HD 22.15:2007 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 15: MULTICORE CABLES INSULATED AND SHEATHED WITH HEAT RESISTANT SILICONE RUBBER
UNE-EN 50264-2-2:2010 Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 2-2: Cables with crosslinked elastomeric insulation - Multicore cables
NF EN 50264-3-2 : 2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 3-2: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION WITH REDUCED DIMENSIONS - MULTICORE CABLES
I.S. HD 22.13:2007 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 13: HALOGEN-FREE FLEXIBLE CABLES HAVING LOW EMISSION OF SMOKE
UNE-EN 50525-2-21:2012 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) -- Part 2-21: Cables for general applications - Flexible cables with crosslinked elastomeric insulation
I.S. EN 60332-1-1:2004 TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 1-1: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED WIRE OR CABLE - APPARATUS
CEI 20-56 : 2010 DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV SOMMARIO
UNE-IEC 60092-354:2015 Electrical installations in ships - Part 354: Single- and three-core power cables with extruded solid insulation for rated voltages 6 kV (U<sub>m</sub> = 7,2 kV) up to 30 kV (U<sub>m</sub> = 36 kV)
CEI EN 50525-2-31 : 2012 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-31: CABLES FOR GENERAL APPLICATIONS - SINGLE CORE NON-SHEATHED CABLES WITH THERMOPLASTIC PVC INSULATION
I.S. EN 60332-2-2:2004 TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 2-2: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE SMALL INSULATED WIRE OR CABLE - PROCEDURE FOR DIFFUSION FLAME
I.S. EN 60332-1-3:2004 TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 1-3: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED WIRE OR CABLE - PROCEDURE FOR DETERMINATION OF FLAMING DROPLETS/PARTICLES
I.S. EN 62052-31:2016 ELECTRICITY METERING EQUIPMENT (AC) - GENERAL REQUIREMENTS, TESTS AND TEST CONDITIONS - PART 31: PRODUCT SAFETY REQUIREMENTS AND TESTS
BS EN 50174-3 : 2013 INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 3: INSTALLATION PLANNING AND PRACTICES OUTSIDE BUILDINGS
BS IEC 61892-5:2014 Mobile and fixed offshore units. Electrical installations Mobile units
NF EN 60079-35-1 : 2011 EXPLOSIVE ATMOSPHERES - PART 35-1: CAPLIGHTS FOR USE IN MINES SUSCEPTIBLE TO FIREDAMP - GENERAL REQUIREMENTS - CONSTRUCTION AND TESTING IN RELATION TO THE RISK OF EXPLOSION
UNE-EN 50143:2010 Cables for signs and luminous-discharge-tube installations operating from a no-load rated output voltage exceeding 1 000 V but not exceeding 10 000 V
UNE-IEC 60092-352:2015 Electrical installations in ships - Part 352: Choice and installation of electrical cables
NF EN 50264-2-1 : 2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION - SINGLE CORE CABLES
I.S. EN 50525-2-41:2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-41: CABLES FOR GENERAL APPLICATIONS - SINGLE CORE CABLES WITH CROSSLINKED SILICONE RUBBER INSULATION
PREN 50525-3-21 : DRAFT 2008 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3-21: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE CROSSLINKED INSULATION, AND LOW EMISSION OF SMOKE
I.S. EN 61375-3-1:2012 ELECTRONIC RAILWAY EQUIPMENT - TRAIN COMMUNICATION NETWORK (TCN) - PART 3-1: MULTIFUNCTION VEHICLE BUS (MVB) (IEC 61375-3-1:2012 (EQV))
UNE-EN 50525-2-51:2012 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) -- Part 2-51: Cables for general applications - Oil resistant control cables with thermoplastic PVC insulation
CSA C22.2 No. 61010.1 : 2012 : INC : UPD 2 : 2016 SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL, AND LABORATORY USE - PART 1: GENERAL REQUIREMENTS
IEC 60364-5-56:2009 Low-voltage electrical installations - Part 5-56: Selection and erection of electrical equipment - Safety services
I.S. HD 22.12:2007 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 12: HEAT RESISTANT EPR CORDS AND FLEXIBLE CABLES
I.S. EN 50525-2-21:2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-21: CABLES FOR GENERAL APPLICATIONS - FLEXIBLE CABLES WITH CROSSLINKED ELASTOMERIC INSULATION
I.S. EN 50143:2009 CABLES FOR SIGNS AND LUMINOUS-DISCHARGE-TUBE INSTALLATIONS OPERATING FROM A NO-LOAD RATED OUTPUT VOLTAGE EXCEEDING 1000 V BUT NOT EXCEEDING 10000 V
IEC 60092-376:2017 Electrical installations in ships - Part 376: Cables for control and instrumentation circuits 150/250 V (300 V)
IEC 60364-4-42:2010+AMD1:2014 CSV Low-voltage electrical installations - Part 4-42: Protection forsafety - Protection against thermal effects
IEC/ISO/IEEE 80005-1:2012 Utility connections in port - Part 1: High Voltage Shore Connection (HVSC) Systems - General requirements
I.S. EN 50525-2-71:2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-71: CABLES FOR GENERAL APPLICATIONS - FLAT TINSEL CABLES (CORDS) WITH THERMOPLASTIC PVC INSULATION
DIN EN 13289:2015-12 (Draft) Pasta processing plant - Dryers and coolers - Safety and hygiene requirements; German and English version prEN 13289:2015
13/30294120 DC : 0 BS IEC 61892-5 ED 3.0 - MOBILE AND FIXED OFFSHORE UNITS - ELECTRICAL INSTALLATIONS - PART 5: MOBILE UNITS
BS EN 1889-1:2011 Machines for underground mines. Mobile machines working underground. Safety Rubber tyred vehicles
07/30091745 DC : 0 BS IEC 62368 - AUDIO/VIDEO, INFORMATION AND COMMUNICATION TECHNOLOGY EQUIPMENT - SAFETY - REQUIREMENTS
12/30269297 DC : 0 BS EN 60079-14/ED 5 - EXPLOSIVE ATMOSPHERES - PART 14: ELECTRICAL INSTALLATIONS DESIGN, SELECTION AND ERECTION
BS EN 50628:2016 Erection of electrical installations in underground mines
IEC 61010-1:2010+AMD1:2016 CSV Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements
IEC 60601-1:2005+AMD1:2012 CSV Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
HD 22.15 : 200S2 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 15: MULTICORE CABLES INSULATED AND SHEATHED WITH HEAT RESISTANT SILICONE RUBBER
HD 22-9 : 200S3 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 9: SINGLE CORE HALOGEN-FREE NON-SHEATHED CABLES FOR FIXED WIRING HAVING LOW EMISSION OF SMOKE
EN 50143:2009 Cables for signs and luminous-discharge-tube installations operating from a no-load rated output voltage exceeding 1 000 V but not exceeding 10 000 V
CEI 18-62 : 2013 MOBILE AND FIXED OFFSHORE UNITS - ELECTRICAL INSTALLATIONS - PART 5: MOBILE UNITS
CEN/TS 45545-2:2009 Railway applications - Fire protection on railway vehicles - Part 2: Requirements for fire behaviour of materials and components
IEC 60364-7-712:2017 RLV Low voltage electrical installations - Part 7-712: Requirements for special installations or locations - Solar photovoltaic (PV) power supply systems
EN 50264-2-2:2008 Railway applications - Railway rolling stock power and control cables having special fire performance - Part 2-2: Cables with crosslinked elastomeric insulation - Multicore cables
EN 50264-3-1:2008 Railway applications - Railway rolling stock power and control cables having special fire performance - Part 3-1: Cables with crosslinked elastomeric insulation with reduced dimensions - Single core cables
EN 50628:2016 Erection of electrical installations in underground mines
EN 50382-2:2008/A1:2013 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2: SINGLE CORE SILICONE RUBBER INSULATED CABLES FOR 120 DEGREES C OR 150 DEGREES C
EN 50214:2006/corrigendum Dec. 2007 FLAT POLYVINYL CHLORIDE SHEATHED FLEXIBLE CABLES
EN 50525-2-82:2011 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-82: Cables for general applications - Cables with crosslinked elastomeric insulation for decorative chains
EN 50525-3-21:2011/AC:2013 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-21: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE CROSSLINKED INSULATION, AND LOW EMISSION OF SMOKE
CLC/TS 50576:2016 Electric cables - Extended application of test results for reaction to fire
EN 60332-1-1:2004/A1:2015 Tests on electric and optical fibre cables under fire conditions - Part 1-1: Test for vertical flame propagation for a single insulated wire or cable - Apparatus
EN 60079-35-1:2011/AC:2011 EXPLOSIVE ATMOSPHERES - PART 35-1: CAPLIGHTS FOR USE IN MINES SUSCEPTIBLE TO FIREDAMP - GENERAL REQUIREMENTS - CONSTRUCTION AND TESTING IN RELATION TO THE RISK OF EXPLOSION
EN 50525-3-41:2011 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 3-41: Cables with special fire performance - Single core non-sheathed cables with halogen-free crosslinked insulation, and low emission of smoke
EN 50525-2-11:2011 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 2-11: Cables for general applications - Flexible cables with thermoplastic PVC insulation
EN 61375-3-1 : 2012 ELECTRONIC RAILWAY EQUIPMENT - TRAIN COMMUNICATION NETWORK (TCN) - PART 3-1: MULTIFUNCTION VEHICLE BUS (MVB) (IEC 61375-3-1:2012)
CEI 18-58 : 2013 MOBILE AND FIXED OFFSHORE UNITS - ELECTRICAL INSTALLATIONS - PART 3: EQUIPMENT
EN 50618:2014 Electric cables for photovoltaic systems
EN 50525-2-21:2011/AC:2013 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-21: CABLES FOR GENERAL APPLICATIONS - FLEXIBLE CABLES WITH CROSSLINKED ELASTOMERIC INSULATION
UNE-HD 620-1:2010 Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV up to and including 20,8/36 (42) kV. Part 1: General requirements.
UNE-HD 60364-4-42:2014 Low voltage electrical installations -- Part 4-42: Protection for safety - Protection against thermal effects
UNE-HD 60364-5-559:2013 Low-voltage electrical installations - Part 5-559: Selection and erection of electrical equipment - Luminaires and lighting installations
UNE-HD 60364-7-717:2013 Low-voltage electrical installations -- Part 7-717: Requirements for special installations or locations - Mobile or transportable units
UNE-HD 60364-5-52:2014 Low-voltage electrical installations -- Part 5-52: Selection and erection of electrical equipment - Wiring systems

AS/NZS IEC 60227.5:2019 Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V Flexible cables (cords)
IEC 60695-4:2012 Fire hazard testing - Part 4: Terminology concerning fire tests for electrotechnical products
AS/NZS IEC 60092.376:2020 Electrical installations in ships Cables for control and instrumentation circuits 150/250 V (300 V)
IEC 60332-2-2:2004 Tests on electric and optical fibre cables under fire conditions - Part 2-2: Test for vertical flame propagation for a single small insulated wire or cable - Procedure for diffusion flame
ISO 13943:2017 Fire safety — Vocabulary
IEC 60811-203:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 203: General tests - Measurement of overall dimensions
IEC 60332-1-1:2004+AMD1:2015 CSV Tests on electric and optical fibre cables under fire conditions - Part 1-1: Test for vertical flame propagation for a single insulatedwire or cable - Apparatus
IEC GUIDE 104:2010 The preparation of safety publications and the use of basic safety publications and group safety publications
AS/NZS 60092.354:2020 Electrical installations in ships Single- and three-core power cables with extruded solid insulation for rated voltages 6 kV (Um = 7,2 kV) up to 30 kV (Um = 36 kV) (IEC 60092-354:2014 (ED.3.0) MOD)
AS/NZS IEC 60092.353:2020 Electrical installations in ships Power cables for rated voltages 1 kV and 3 kV

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.