IEC 60060-2:2010
Current
The latest, up-to-date edition.
High-voltage test techniques - Part 2: Measuring systems
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English, English - French, Spanish, Castilian
29-11-2010
FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 Procedures for qualification and use of
measuring systems
5 Tests and test requirements for an approved
measuring system and its components
6 Measurement of direct voltage
7 Measurement of alternating voltage
8 Measurement of lightning impulse voltage
9 Measurement of switching impulse voltage
10 Reference measuring systems
Annex A (informative) - Uncertainty of measurement
Annex B (informative) - Examples for the calculation
of measuring uncertainties in high-voltage
measurements
Annex C (informative) - Step response measurements
Annex D (informative) - Convolution method for the
determination of dynamic behaviour from step
response measurements
Bibliography
IEC 60060-2:2010 is applicable to complete measuring systems, and to their components, used for the measurement of high voltages during laboratory and factory tests with direct voltage, alternating voltage and lightning and switching impulse voltages as specified in IEC 60060-1. For measurements during on-site tests see IEC 60060-3. The limits on uncertainties of measurements stated in this standard apply to test levels stated in IEC 60071-1:2006. The principles of this standard apply also to higher levels but the uncertainty may be greater. This standard also defines the terms used, methods to estimate the uncertainties of high-voltage measurements, states the requirements which the measuring systems shall meet, describes the methods for approving a measuring system and checking its components and describes the procedures by which the user shall show that a measuring system meets the requirements of this standard, including the limits set for the uncertainty of measurement. This third edition cancels and replaces the second edition, published in 1994, and constitutes a technical revision. The significant technical changes with respect to the previous edition are as follows:
- The general layout and text was updated and improved to make the standard easier to use.
- The standard was revised to align it with IEC 60060-1.
- The treatment of measurement uncertainty estimation has been expanded.
Committee |
TC 42
|
DevelopmentNote |
Supersedes IEC 60060-4 (03/2001) Supersedes IEC 60060. (07/2004) Stability Date: 2017. (10/2012)
|
DocumentType |
Standard
|
Pages |
154
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes |
Standards | Relationship |
NF EN 60060-2 : 2011 | Identical |
NBN EN 60060-2 : 2011 | Identical |
NEN EN IEC 60060-2 : 2011 | Identical |
I.S. EN 60060-2:2011 | Identical |
VDE 0432-2 : 2011 | Identical |
DIN EN 60060-2 : 2011 | Identical |
UNE-EN 60060-2:2012 | Identical |
BIS IS/IEC 60060-2 : 2010 | Identical |
CEI EN 60060-2 : 2015 | Identical |
EN 60060-2:2011 | Identical |
AS IEC 60060.2:2018 | Identical |
NEN 10060-2 : 1995 | Identical |
NBN C 83 250 : 1984 AMD 1 1988 | Identical |
BS EN 60060-2:2011 | Identical |
BS EN 60060-2:1995 | Identical |
PN EN 60060-2 : 2011 | Identical |
SN EN 60060-2 : 1994 AMD 11 1998 | Identical |
UNE 21308-2:1976 | Identical |
04/30108943 DC : 0 | |
CEI EN 60358-2 : 2015 | COUPLING CAPACITORS AND CAPACITOR DIVIDERS - PART 2: AC OR DC SINGLE-PHASE COUPLING CAPACITOR CONNECTED BETWEEN LINE AND GROUND FOR POWER LINE CARRIER-FREQUENCY (PLC) APPLICATION |
BS IEC 62895:2017 | High voltage direct current (HVDC) power transmission. Cables with extruded insulation and their accessories for rated voltages up to 320 kV for land applications. Test methods and requirements |
14/30300746 DC : 0 | BS EN 60358-4 ED 1.0 - COUPLING CAPACITORS AND CAPACITOR DIVIDERS - PART 4: AC AND DC SINGLE-PHASE CAPACITOR-DIVIDER AND RC-DIVIDER |
14/30281093 DC : 0 | BS EN 60855-1 - LIVE WORKING - INSULATING FOAM-FILLED TUBES AND SOLID RODS - PART 1: TUBES AND RODS OF A CIRCULAR CROSS-SECTION |
BS EN 60855-1:2017 | Live working. Insulating foam-filled tubes and solid rods Tubes and rods of a circular cross-section |
IEC 60034-27-3:2015 | Rotating electrical machines - Part 27-3: Dielectric dissipation factor measurement on stator winding insulation of rotating electrical machines |
BS EN 60143-4:2010 | Series capacitors for power systems Thyristors controlled series capacitors |
BS EN 62271-106:2011 | High-voltage switchgear and controlgear Alternating current contactors, contactor-based controllers and motor-starters |
06/30149562 DC : DRAFT APR 2006 | IEC 61083-2 - INSTRUMENTS AND SOFTWARE USED FOR MEASUREMENTS IN HIGH-VOLTAGE IMPULSE TEST - PART 2: REQUIREMENTS FOR SOFTWARE |
NF EN 61180 : 2016 | HIGH-VOLTAGE TEST TECHNIQUES FOR LOW-VOLTAGE EQUIPMENT - DEFINITIONS, TEST AND PROCEDURE REQUIREMENTS, TEST EQUIPMENT |
11/30233201 DC : 0 | BS EN 61009-1 - RESIDUAL CURRENT OPERATED CIRCUIT-BREAKERS WITH INTEGRAL OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR USES (RCBOS) - PART 1: GENERAL RULES |
BS EN 61112:2009 | Live working. Electrical insulating blankets |
07/30158043 DC : 0 | BS EN 62501 - ELECTRICAL TESTING OF VOLTAGE SOURCE CONVERTER (VSC) VALVES FOR HIGH-VOLTAGE DIRECT CURRENT (HVDC) POWER TRANSMISSION |
DEFSTAN 61-5(PT4)/2(1992) : 1992 | ELECTRICAL POWER SUPPLY SYSTEMS BELOW 650 VOLTS - PART 4: POWER SUPPLIES IN HM SHIPS |
BS IEC/IEEE 62271-37-013:2015 | High-voltage switchgear and controlgear Alternating-current generator circuit-breakers |
CEI EN 60060-3 : 2006 | HIGH VOLTAGE TEST TECHNIQUES - PART 3: DEFINITIONS AND REQUIREMENTS FOR ON-SITE TESTS |
PD IEC/TR 63042-100:2016 | UHV AC transmission systems General information |
14/30257408 DC : 0 | BS IEC/IEEE 62271-37-013 ED 1.0 - HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 37-013: ALTERNATING-CURRENT GENERATOR CIRCUIT-BREAKERS |
NFC 18 422 : 2007 | BLANKETS OF INSULATING MATERIAL FOR ELECTRICAL PURPOSES |
BS EN 60831-1:2014 | Shunt power capacitors of the self-healing type for a.c. systems having a rated voltage up to and including 1 000 V General. Performance, testing and rating. Safety requirements. Guide for installation and operation |
BS 4999-115:1992 | General requirements for rotating electrical machines Impulse voltage withstand levels of rotating a.c. machines with form-wound stator coils |
CAN/CSA-C156.3-M86 (R2013) | Test Methods for Station Post Insulators |
OVE/ONORM EN 61051-1 : 2009 | VARISTORS FOR USE IN ELECTRONIC EQUIPMENT - PART 1: GENERIC SPECIFICATION |
CEI EN 60052 : 2003 | VOLTAGE MEASUREMENT BY MEANS OF STANDARD AIR GAPS |
CEI EN 61083-2 : 2014 | INSTRUMENTS AND SOFTWARE USED FOR MEASUREMENT IN HIGH-VOLTAGE AND HIGH-CURRENT TESTS - PART 2: REQUIREMENTS FOR SOFTWARE FOR TESTS WITH IMPULSE VOLTAGES AND CURRENTS |
I.S. EN 60143-4:2010 | SERIES CAPACITORS FOR POWER SYSTEMS - PART 4: THYRISTOR CONTROLLED SERIES CAPACITORS |
CAN/CSA-ISO/IEC 8802-5-02 (R2011) | Information Technology - Telecommunications and Information Exchange Between Systems - Local and Metropolitan Area Networks - Specific Requirements - Part 5: Token Ring Access Method and Physical Layer Specifications (Adopted ISO/IEC 8802-5:1998 / ANSI/IEEE 802.5:1998, third edition, 1998-09-15) |
CSA C156.3 : 1986 : R1999 | TEST METHODS FOR STATION POST INSULATORS |
I.S. EN 60244-1:2000 | METHODS OF MEASUREMENT FOR RADIO TRANSMITTERS - PART 1: GENERAL CHARACTERISTICS FOR BROADCAST TRANSMITTERS |
I.S. EN IEC 60099-8:2018 | SURGE ARRESTERS - PART 8: METAL-OXIDE SURGE ARRESTERS WITH EXTERNAL SERIES GAP (EGLA) FOR OVERHEAD TRANSMISSION AND DISTRIBUTION LINES OF A.C. SYSTEMS ABOVE 1 KV |
CEI EN 50321 : 2000 | ELECTRICALLY INSULATING FOOTWEAR FOR WORKING ON LOW VOLTAGE INSTALLATIONS |
I.S. EN 61051-1:2008 | VARISTORS FOR USE IN ELECTRONIC EQUIPMENT - PART 1: GENERIC SPECIFICATION |
SAE ARP5416A | Aircraft Lightning Test Methods |
I.S. EN 60052:2002 | VOLTAGE MEASUREMENT BY MEANS OF STANDARD AIR GAPS |
EN IEC 60099-8:2018 | Surge arresters - Part 8: Metal-oxide surge arresters with external series gap (EGLA) for overhead transmission and distribution lines of a.c. systems above 1 kV |
I.S. EN 61000-4-5:2014 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-5: TESTING AND MEASUREMENT TECHNIQUES - SURGE IMMUNITY TEST |
I.S. EN 132400:1994 | SECTIONAL SPECIFICATION: FIXED CAPACITORS FOR ELECTROMAGNETIC INTERFERENCE SUPPRESSION AND CONNECTION TO THE SUPPLY MAINS (ASSESSMENT LEVEL D) |
CEI EN 50365 : 2004 | ELECTRICALLY INSULATING HELMETS FOR USE ON LOW VOLTAGE INSTALLATIONS |
UNE-EN 60099-4:2016 | Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems |
CEI EN 60244-1 : 2000 | METHODS OF MEASUREMENT FOR RADIO TRANSMITTERS - PART 1: GENERAL CHARACTERISTICS FOR BROADCAST TRANSMITTERS |
I.S. EN 60358-3:2014 | COUPLING CAPACITORS AND CAPACITOR DIVIDERS - PART 3: AC OR DC COUPLING CAPACITORS FOR HARMONIC-FILTERS APPLICATIONS |
UNE-EN 60855-1:2017 | Live working - Insulating foam-filled tubes and solid rods - Part 1: Tubes and rods of a circular cross-section |
IEC 60143-1:2015 | Series capacitors for power systems - Part 1: General |
EN 60099-4:2014 | Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems |
EN 61083-1:2001 | Instruments and software used for measurement in high-voltage impulse tests - Part 1: Requirements for instruments |
EN 60052:2002 | Voltage measurement by means of standard air gaps |
EN 61112:2009 | Live working - Electrical insulating blankets |
EN 61479:2001/A1:2002 | LIVE WORKING - FLEXIBLE CONDUCTOR COVERS (LINE HOSES) OF INSULATING MATERIAL |
EN 61083-2:2013 | Instruments and software used for measurement in high-voltage and high-current tests - Part 2: Requirements for software for tests with impulse voltages and currents |
EN 61111 : 2009 | LIVE WORKING - ELECTRICAL INSULATING MATTING |
EN 60270:2001/A1:2016 | HIGH-VOLTAGE TEST TECHNIQUES - PARTIAL DISCHARGE MEASUREMENTS (IEC 60270:2000/A1:2015) |
EN 60831-1:2014/AC:2014 | SHUNT POWER CAPACITORS OF THE SELF-HEALING TYPE FOR A.C. SYSTEMS HAVING A RATED VOLTAGE UP TO AND INCLUDING 1000 V - PART 1: GENERAL - PERFORMANCE, TESTING AND RATING - SAFETY REQUIREMENTS - GUIDE FOR INSTALLATION AND OPERATION |
EN 61180:2016 | High-voltage test techniques for low-voltage equipment - Definitions, test and procedure requirements, test equipment |
EN 61180-2:1994 | High-voltage test techniques for low-voltage equipment - Part 2: Test equipment |
EN 61011:1992/A11:1996 | ELECTRIC FENCE ENERGIZERS - SAFETY REQUIREMENTS FOR MAINS-OPERATED ELECTRIC FENCE ENERGIZERS |
EN 61051-1:2008 | Varistors for use in electronic equipment - Part 1: Generic specification |
EN 60143-1:2015/AC:2017-05 | Series capacitors for power systems - Part 1: General |
EN 62606:2013/A1:2017 | GENERAL REQUIREMENTS FOR ARC FAULT DETECTION DEVICES (IEC 62606:2013/A1:2017) |
EN 60060-3:2006/corrigendum Oct. 2006 | HIGH VOLTAGE TEST TECHNIQUES - PART 3: DEFINITIONS AND REQUIREMENTS FOR ON-SITE TESTS |
EN 60034-27-3:2016 | Rotating electrical machines - Part 27-3: Dielectric dissipation factor measurement on stator winding insulation of rotating electrical machines |
EN 60289:1994/A11:2002 | REACTORS |
EN 61000-4-5:2014/A1:2017 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-5: TESTING AND MEASUREMENT TECHNIQUES - SURGE IMMUNITY TEST (IEC 61000-4-5:2014/A1:2017) |
EN 133000:1997 | Generic Specification: Passive filter units for electromagnetic interference suppression |
BS EN 60060-1:2010 | High-voltage test techniques General definitions and test requirements |
09/30176337 DC : 0 | BS EN 61954 - POWER ELECTRONICS FOR ELECTRICAL TRANSMISSION AND DISTRIBUTION SYSTEMS - TESTING OF THYRISTOR VALVES FOR STATIC VAR COMPENSATORS |
11/30255306 DC : 0 | BS EN 60358-3 - COUPLING CAPACITORS AND CAPACITOR DIVIDERS - PART 3: AC OR DC COUPLING CAPACITOR FOR HARMONIC-FILTERS APPLICATIONS |
06/30149569 DC : DRAFT APR 2006 | IEC 60060-1 - HIGH-VOLTAGE TEST TECHNIQUES - PART 1: GENERAL DEFINITIONS AND TEST REQUIREMENTS |
14/30290103 DC : 0 | BS EN 62895 - HIGH VOLTAGE DIRECT CURRENT (HVDC) POWER TRANSMISSION CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES UP TO 320KV FOR LAND APPLICATIONS - TEST METHODS AND REQUIREMENTS |
BS EN 60358-1:2012 | Coupling capacitors and capacitor dividers General rules |
13/30286196 DC : 0 | BS EN 61245 - ARTIFICIAL POLLUTION TESTS ON HIGH-VOLTAGE INSULATORS TO BE USED ON D.C SYSTEM |
NF EN 60903 : 2004 | SPECIFICATION FOR GLOVES AND MITTS OF INSULATING MATERIAL FOR LIVE WORKING |
01/203455 DC : DRAFT MAY 2001 | IEC 60143-1 ED.4.0 - SERIES CAPACITORS FOR POWER SYSTEMS |
12/30253687 DC : DRAFT JUNE 2012 | BS EN 62478 - HIGH VOLTAGE TEST TECHNIQUES - MEASUREMENT OF PARTIAL DISCHARGES BY ELECTROMAGNETIC AND ACOUSTIC METHODS |
EN 60143 : 93 AC 94 | SERIES CAPACITORS FOR POWER SYSTEMS - GENERAL PERFORMANCE, TESTING AND RATING - SAFETY REQUIREMENTS - GUIDE FOR INSTALLATION |
13/30294291 DC : 0 | BS EN 62561-8 - LIGHTNING PROTECTION SYSTEM COMPONENTS (LPSC) - PART 8: REQUIREMENTS FOR COMPONENTS FOR ISOLATED LPS |
CSA CEI/IEC 61000.4.9 : 2002 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-9: TESTING AND MEASUREMENT TECHNIQUES - PULSE MAGNETIC FIELD IMMUNITY TEST |
99/201503 DC : 0 | IEC 61479 ED.1 - LIVE WORKING - CONDUCTOR COVERS (LINE HOSES) OR INSULATING MATERIAL FOR ELECTRICAL PURPOSES |
02/206916 DC : DRAFT MAY 2002 | IEC 62237. ED.1 - LIVE WORKING - INSULATING HOSES FOR USE WITH HYDRAULIC TOOLS AND EQUIPMENT |
PREN 61008-1 : DRAFT 2011 | RESIDUAL CURRENT OPERATED CIRCUIT-BREAKERS WITHOUT INTEGRAL OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR USES (RCCBS) - PART 1: GENERAL RULES |
DIN EN 61954 : 2018 | STATIC VAR COMPENSATORS (SVC) - TESTING OF THYRISTOR VALVES (IEC 61954:2011 + A1:2013 + A2:2017) |
13/30291844 DC : 0 | BS EN 60230 - IMPULSE TESTS ON CABLES AND THEIR ACCESSORIES |
08/30175871 DC : DRAFT JAN 2008 | BS EN 61112 - LIVE WORKING - ELECTRICAL INSULATING BLANKETS |
16/30339801 DC : 0 | BS EN 63052 - POWER FREQUENCY OVERVOLTAGE PROTECTIVE DEVICES FOR HOUSEHOLD AND SIMILAR APPLICATIONS (POP) |
03/100554 DC : DRAFT APR 2003 | IEC 60060-3 ED.1 - HIGH VOLTAGE TEST TECHNIQUES - PART 3: DEFINITIONS AND REQUIREMENTS FOR ON-SITE TESTS |
I.S. EN 60034-27-3:2016 | ROTATING ELECTRICAL MACHINES - PART 27-3: DIELECTRIC DISSIPATION FACTOR MEASUREMENT ON STATOR WINDING INSULATION OF ROTATING ELECTRICAL MACHINES |
11/30233197 DC : 0 | BS EN 61008-1 - RESIDUAL CURRENT OPERATED CIRCUIT-BREAKERS WITHOUT INTEGRAL OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR USES (RCCBS) - PART 1: GENERAL RULES |
BS HD 60269-2:2013 | Low-voltage fuses Supplementary requirements for fuses for use by authorized persons (fuses mainly for industrial application). Examples of standardized systems of fuses A to K |
BS EN 61479:2001 | Live working. Flexible conductor covers (line hoses) of insulating material |
I.S. EN 62606:2013 | GENERAL REQUIREMENTS FOR ARC FAULT DETECTION DEVICES |
09/30167595 DC : 0 | BS EN 60099-8 ED.1 - SURGE ARRESTERS - PART 8: METAL-OXIDE SURGE ARRESTERS WITH EXTERNAL SERIES GAP (EGLA) FOR OVERHEAD TRANSMISSION AND DISTRIBUTION LINES OF A.C. SYSTEMS ABOVE 1 KV |
03/307802 DC : DRAFT MAY 2003 | EN 61008-1 - RESIDUAL CURRENT OPERATED CIRCUIT-BREAKERS WITHOUT INTEGRAL OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR USES (RCCB'S) - PART 1: GENERAL RULES |
BS EN 61083-2:2013 | Instruments and software used for measurement in high-voltage and high-current tests Requirements for software for tests with impulse voltages and currents |
BS EN 60076-4:2002 | Power transformers Guide to the lightning impulse and switching impulse testing. Power transformers and reactors |
BS EN 50321:2000 | Electrically insulating footwear for working on low voltage installations |
PREN 61009-1 : DRAFT 2011 | RESIDUAL CURRENT OPERATED CIRCUIT-BREAKERS WITH INTEGRAL OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR USES (RCBOS) - PART 1: GENERAL RULES |
CSA C156.3 : 1986 : R2009 | TEST METHODS FOR STATION POST INSULATORS |
CEI EN 61111 : 2010 | LIVE WORKING - ELECTRICAL INSULATING MATTING |
IEC 60269-2:2013+AMD1:2016 CSV | Low-voltage fuses - Part 2: Supplementary requirements for fuses for use by authorized persons (fuses mainly for industrial application) - Examples of standardized systems of fuses A to K |
CEI EN 60076-4 : 2003 | POWER TRANSFORMERS - PART 4: GUIDE TO LIGHTNING IMPULSE AND SWITCHING IMPULSE TESTING - POWER TRANSFORMERS AND REACTORS |
NF EN 60060-1 : 2011 | HIGH-VOLTAGE TEST TECHNIQUES - PART 1: GENERAL DEFINITIONS AND TEST REQUIREMENTS |
BS EN 60310:2016 | Railway applications. Traction transformers and inductors on board rolling stock |
IEC TR 63042-100:2016 | UHV AC transmission systems - Part 100: General information |
IEEE C37.100.1-2007 | IEEE Standard of Common Requirements for High Voltage Power Switchgear Rated Above 1000 V |
I.S. EN 50321-1:2018 | LIVE WORKING - FOOTWEAR FOR ELECTRICAL PROTECTION - INSULATING FOOTWEAR AND OVERBOOTS |
I.S. EN 60310:2016 | RAILWAY APPLICATIONS - TRACTION TRANSFORMERS AND INDUCTORS ON BOARD ROLLING STOCK |
I.S. HD 632:2016 | POWER CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES ABOVE 36 KV (U[M] = 42 KV) UP TO 150 KV (U[M] = 170 KV) |
NF EN 61112 : 2009 | LIVE WORKING - ELECTRICAL INSULATING BLANKETS |
I.S. EN 60358-1:2012 | COUPLING CAPACITORS AND CAPACITOR DIVIDERS - PART 1: GENERAL RULES (IEC 60358-1:2012 (EQV)) |
I.S. HD 60269-2-1:2005 | LOW-VOLTAGE FUSES - PART 2-1: SUPPLEMENTARY REQUIREMENTS FOR FUSES FOR USE BY AUTHORIZED PERSONS (FUSES MAINLY FOR INDUSTRIAL APPLICATION) - SECTIONS 1 TO 6: EXAMPLES OF TYPES OF STANDARDIZED FUSES |
I.S. EN 60831-1:2014-2015-10 | SHUNT POWER CAPACITORS OF THE SELF-HEALING TYPE FOR A.C. SYSTEMS HAVING A RATED VOLTAGE UP TO AND INCLUDING 1000 V - PART 1: GENERAL - PERFORMANCE, TESTING AND RATING - SAFETY REQUIREMENTS - GUIDE FOR INSTALLATION AND OPERATION |
VDE 0553-100 : 2018 | STATIC VAR COMPENSATORS (SVC) - TESTING OF THYRISTOR VALVES (IEC 61954:2011 + A1:2013 + A2:2017) |
EN 50321-1:2018 | Live working - Footwear for electrical protection - Insulating footwear and overboots |
IEC 60099-8:2017 | Surge arresters - Part 8: Metal-oxide surge arresters with external series gap (EGLA) for overhead transmission and distribution lines of a.c. systems above 1 kV |
PREN 50321 : DRAFT 2013 | LIVE WORKING - FOOTWEAR FOR ELECTRICAL PROTECTION - INSULATING FOOTWEAR AND OVERBOOTS |
CEI EN 60099-4 : 2015 | SURGE ARRESTERS - PART 4: METAL-OXIDE SURGE ARRESTERS WITHOUT GAPS FOR A.C. SYSTEMS |
NF EN 50365 : 2002 | ELECTRICALLY INSULATING HELMETS FOR USE ON LOW VOLTAGE INSTALLATIONS |
CEI EN 60143-4 : 2012 | SERIES CAPACITORS FOR POWER SYSTEMS - PART 4: THYRISTOR CONTROLLED SERIES CAPACITORS |
IEC 61008-1:2010+AMD1:2012+AMD2:2013 CSV | Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) - Part1: General rules |
IEC 61643-21:2000+AMD1:2008+AMD2:2012 CSV | Low voltage surge protective devices - Part 21: Surge protective devices connected to telecommunications and signalling networks - Performance requirements and testing methods |
I.S. EN 61954:2011 | STATIC VAR COMPENSATORS (SVC) - TESTING OF THYRISTOR VALVES |
I.S. EN 60076-4:2002 | POWER TRANSFORMERS - PART 4: GUIDE TO THE LIGHTNING IMPULSE AND SWITCHING IMPULSE TESTING - POWER TRANSFORMERS AND REACTORS |
IEC 60099-6:2002 | Surge arresters - Part 6: Surge arresters containing both series and parallel gapped structures - Rated 52 kV and less |
PD IEC/TS 63053:2017 | General requirements for residual current operated protective devices for DC systems |
BS EN ISO 10440-2:2001 | Petroleum and natural gas industries. Rotary-type positive-displacement compressors Packaged air compressors (oil-free) |
BS 2692-1(1986) : 1986 AMD 8047 | FUSES FOR VOLTAGES EXCEEDING 1000 V a.c. - SPECIFICATION FOR CURRENT LIMITING FUSES |
VDE 0532-20 : 1994 | REACTORS |
BS 88-2(2013) : 2013 COR 2014 | LOW-VOLTAGE FUSES - PART 2: SUPPLEMENTARY REQUIREMENTS FOR FUSES FOR USE BY AUTHORIZED PERSONS (FUSES MAINLY FOR INDUSTRIAL APPLICATION) - EXAMPLES OF STANDARDIZED SYSTEMS OF FUSES A TO K |
KTA 3504 : 2015(R2017) | |
BS 88-2:2007 | Low-voltage fuses Supplementary requirements for fuses for use by authorized persons (fuses mainly for industrial application). Examples of standardized systems of fuses A to I |
VDE 0804 : 1989 AMD 1 1992 | TELECOMMUNICATIONS; ADDITIONAL REQUIREMENTS FOR CONSTRUCTION AND TESTING OF APPARATUS |
BS 4828:1985 | Guide for partial discharge measurements |
BS 88-2(2010) : 2010 | LOW-VOLTAGE FUSES - PART 2: SUPPLEMENTARY REQUIREMENTS FOR FUSES FOR USE BY AUTHORIZED PERSONS (FUSES MAINLY FOR INDUSTRIAL APPLICATION) - EXAMPLES OF STANDARDIZED SYSTEMS OF FUSES A TO J |
CEI EN 60903 : 2005 | LIVE WORKING - GLOVES OF INSULATING MATERIAL IMPIANTI |
BS EN 60052:2002 | Voltage measurement by means of standard air gaps |
IEEE 4-2013 | IEEE Standard for High-Voltage Testing Techniques |
17/30356577 DC : 0 | BS EN 60099-8 - SURGE ARRESTERS - PART 8: METAL-OXIDE SURGE ARRESTERS WITH EXTERNAL SERIES GAP (EGLA) FOR OVERHEAD TRANSMISSION AND DISTRIBUTION LINES OF A.C. SYSTEMS ABOVE 1 KV |
08/30175867 DC : DRAFT JAN 2008 | BS EN 61111 - LIVE WORKING - ELECTRICAL INSULATING MATTING |
03/309760 DC : DRAFT JUNE 2003 | IEC 62257-3 - RECOMMENDATIONS FOR SMALL RENEWABLE ENERGY AND HYBRID SYSTEMS FOR RURAL ELECTRIFICATION - PART 3: PROJECT DEVELOPMENT AND MANAGEMENT |
BS EN 61111 : 2010 | LIVE WORKING - ELECTRICAL INSULATING MATTING |
BS 7404-2.1(1991) : 1991 | TELECONTROL EQUIPMENT AND SYSTEMS - OPERATING CONDITIONS - SPECIFICATION FOR CLASSES OF ENVIRONMENTAL CONDITIONS AND POWER SUPPLIES |
BS 923-4:1980 | Guide on high-voltage testing techniques Application guide for measuring devices |
BS EN 60358-3:2014 | Coupling capacitors and capacitor dividers AC or DC coupling capacitors for harmonic-filters applications |
14/30310457 DC : 0 | BS EN 60143-1 - SERIES CAPACITORS FOR POWER SYSTEMS - PART 1: GENERAL |
UNE-HD 60269-2:2014 | Low-voltage fuses - Part 2: Supplementary requirements for fuses for use by authorized persons (fuses mainly for industrial application) - Examples of standardized systems of fuses A to K |
CEI EN 61112 : 2010 | LIVE WORKING - ELECTRICAL INSULATING BLANKETS |
BS EN 132400:1995 | Harmonized system of quality assessment for electronic components. Sectional specification. Fixed capacitors for electromagnetic interference suppression and connection to the supply mains (Assessment Level D) |
97/231700 DC : DRAFT DEC 1997 | IEC 60115-1 - FIXED RESISTORS FOR USE IN ELECTRONIC EQUIPMENT - PART 1: GENERIC SPECIFICATION |
UNE-EN 61008-1:2013 | Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) - Part 1: General rules |
DEFSTAN 61-5(PT4)/2(1990) : DRAFT | ELECTRICAL POWER SUPPLY SYSTEMS BELOW 650 VOLTS - PART 4: POWER SUPPLIES IN HM SHIPS |
I.S. EN IEC 60230:2018 | IMPULSE TESTS ON CABLES AND THEIR ACCESSORIES |
14/30318963 DC : DRAFT DEC 2014 | BS EN 61057 - LIVE WORKING - INSULATING AERIAL DEVICES FOR MOUNTING ON A CHASSIS |
BS 5622-1:1979 | Guide for insulation co-ordination Terms, definitions, principles and rules |
10/30232718 DC : 0 | BS EN 60076-3 - POWER TRANSFORMERS - PART 3: INSULATION LEVELS, DIELECTRIC TESTS AND EXTERNAL CLEARANCES IN AIR |
03/318812 DC : DRAFT NOV 2003 | IEC 62257-3 TS ED.1 - RECOMMENDATIONS FOR SMALL RENEWABLE ENERGY AND HYBRID SYSTEMS FOR RURAL ELECTRIFICATION - PART 3: PROJECT DEVELOPMENT AND MANAGEMENT |
DD IEC TS 62257-3 : DRAFT 2004 | RECOMMENDATIONS FOR SMALL RENEWABLE ENERGY AND HYBRID SYSTEMS FOR RURAL ELECTRIFICATION - PART 3: PROJECT DEVELOPMENT AND MANAGEMENT |
CEI 32-12 : 2014 | LOW-VOLTAGE FUSES - PART 2: SUPPLEMENTARY REQUIREMENTS FOR FUSES FOR USE BY AUTHORIZED PERSONS (FUSES MAINLY FOR INDUSTRIAL APPLICATION) - EXAMPLES OF STANDARDIZED SYSTEMS OF FUSES A TO K |
04/30123989 DC : DRAFT OCT 2004 | IEC 61643-11 - SURGE PROTECTION DEVICES CONNECTED TO LOW-VOLTAGE POWER DISTRIBUTION SYSTEMS - PART 11: PERFORMANCE REQUIREMENTS AND TESTING METHODS |
CEI EN 61083-1 : 2002 | INSTRUMENTS AND SOFTWARE USED FOR MEASUREMENTS IN HIGH-VOLTAGE IMPULSE TESTS PART 1: REQUIREMENTS FOR INSTRUMENTS |
BS EN 61011:1993 | Electric fence energizers. Safety requirements for mains-operated electric fence energizers |
NF EN 61211 : 2005 | INSULATORS OF CERAMIC MATERIAL OR GLASS FOR OVERHEAD LINES WITH A NOMINAL VOLTAGE GREATER THAN 1 000 V - IMPULSE PUNCTURE TESTING IN AIR |
03/307803 DC : DRAFT MAY 2003 | EN 61009-1 - RESIDUAL CURRENT OPERATED CIRCUIT-BREAKERS WITH INTEGRAL OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR USES (RCCB'S) - PART 1: GENERAL RULES |
09/30210369 DC : DRAFT SEP 2009 | IEC 61643-11 - LOW-VOLTAGE SURGE PROTECTIVE DEVICES - PART 11: SURGE PROTECTIVE DEVICES CONNECTED TO LOW-VOLTAGE POWER DISTRIBUTION SYSTEMS - PERFORMANCE REQUIREMENTS AND TESTING METHODS |
I.S. EN 61008-1:2012&A1:2014/ac&A2:2014...A12:2017 | RESIDUAL CURRENT OPERATED CIRCUIT-BREAKERS WITHOUT INTEGRAL OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR USES (RCCBS) - PART 1: GENERAL RULES |
PD IEC/TS 62257-3:2015 | Recommendations for renewable energy and hybrid systems for rural electrification Project development and management |
BS EN 133000:1997 | Harmonized system of quality assessment for electronic components. Generic specification: passive filter units for electromagnetic interference suppression |
14/30271248 DC : 0 | BS EN 60310 ED 4.0 - RAILWAY APPLICATIONS - TRACTION TRANSFORMERS AND INDUCTORS ON BOARD ROLLING STOCK |
ISA S82.01 : 1994 | ELECTRICAL AND ELECTRONIC TEST, MEASURING, CONTROLLING AND RELATED EQUIPMENT - GENERAL REQUIREMENTS |
BS EN 60099-8:2011 | Surge arresters Metal-oxide surge arresters with external series gap (EGLA) for overhead transmission and distribution lines of a.c. systems above 1 kV |
BS EN 50463:2007 | Railway applications. Energy measurement on board trains |
CSA ISO/IEC 8802-5 : 2002 | INFORMATION TECHNOLOGY - TELECOMMUNICATIONS AND INFORMATION EXCHANGE BETWEEN SYSTEMS - LOCAL AND METROPOLITAN AREA NETWORKS - SPECIFIC REQUIREMENTS - PART 5: TOKEN RING ACCESS METHOD AND PHYSICAL LAYER SPECIFICATIONS |
BS 5622-2:1979 | Guide for insulation co-ordination Application guide |
UNE-EN 61000-4-5:2015 | Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test |
BIS IS 12640-2 : 2008 | RESIDUAL CURRENT OPERATED CIRCUIT-BREAKING FOR HOUSEHOLD AND SIMILAR USES - PART 2: CIRCUIT-BREAKERS WITH INTEGRAL OVERCURRENT PROTECTION (RCBOS) |
IEC 60230:2018 | Impulse tests on cables and their accessories |
BS EN 60289:1995 | Reactors |
CSA C156.1 : 1986 : R2004 | CERAMIC AND GLASS STATION POST INSULATORS |
CSA C156.1 : 1986 : R2013 | CERAMIC AND GLASS STATION POST INSULATORS |
CEI EN 61180 : 1ED 2017 | HIGH-VOLTAGE TEST TECHNIQUES FOR LOW-VOLTAGE EQUIPMENT - DEFINITIONS, TEST AND PROCEDURE REQUIREMENTS, TEST EQUIPMENT |
I.S. EN 61643-11:2012 | LOW-VOLTAGE SURGE PROTECTIVE DEVICES - PART 11: SURGE PROTECTIVE DEVICES CONNECTED TO LOW-VOLTAGE POWER SYSTEMS - REQUIREMENTS AND TESTS METHODS |
BS EN 61643-21 : 2001 | LOW VOLTAGE SURGE PROTECTIVE DEVICES - PART 21: SURGE PROTECTIVE DEVICES CONNECTED TO TELECOMMUNICATIONS AND SIGNALLING NETWORKS - PERFORMANCE REQUIREMENTS AND TESTING METHODS |
BS EN 60270 : 2001 | HIGH-VOLTAGE TEST TECHNIQUES - PARTIAL DISCHARGE MEASUREMENTS |
EN 61057:2017 | Live working - Insulating aerial devices for mounting on a chassis |
I.S. EN 61057:2017 | LIVE WORKING - INSULATING AERIAL DEVICES FOR MOUNTING ON A CHASSIS |
I.S. EN 61211:2005 | INSULATORS OF CERAMIC MATERIAL OR GLASS FOR OVERHEAD LINES WITH A NOMINAL VOLTAGE GREATER THAN 1000 V - IMPULSE PUNCTURE TESTING IN AIR |
CEI EN 62606 : 2014 | GENERAL REQUIREMENTS FOR ARC FAULT DETECTION DEVICES |
I.S. EN 133000:1998 | PASSIVE FILTER UNITS FOR ELECTROMAGNETIC INTERFERENCE SUPPRESSION (GENERIC SPECIFICATION) |
EN IEC 60230:2018 | Impulse tests on cables and their accessories |
IEC TS 62257-3:2015 | Recommendations for renewable energy and hybrid systems for rural electrification - Part 3: Project development and management |
I.S. EN 60099-4:2014 | SURGE ARRESTERS - PART 4: METAL-OXIDE SURGE ARRESTERS WITHOUT GAPS FOR A.C. SYSTEMS |
I.S. EN 61479:2001 | LIVE WORKING - FLEXIBLE CONDUCTOR COVERS (LINE HOSES) OF INSULATING MATERIAL |
IEC 60984:2014 | Live working - Electrical insulating sleeves |
IEC TR 61000-5-3:1999 | Electromagnetic compatibility (EMC) - Part 5-3: Installation and mitigation guidelines - HEMP protection concepts |
IEC 60755:2017 | General safety requirements for residual current operated protective devices |
I.S. EN 60270:2001 | HIGH-VOLTAGE TEST TECHNIQUES - PARTIAL DISCHARGE MEASUREMENTS |
IEC 60903:2014 | Live working - Electrical insulating gloves |
IEC 60076-3:2013+AMD1:2018 CSV | POWER TRANSFORMERS - PART 3: INSULATION LEVELS, DIELECTRIC TESTS AND EXTERNAL CLEARANCES IN AIR |
IEC TS 61245:2015 | Artificial pollution tests on high-voltage ceramic and glass insulators to be used on d.c. systems |
IEC 61051-1:2007 | Varistors for use in electronic equipment - Part 1: Generic specification |
IEC 60143-4:2010 | Series capacitors for power systems - Part 4: Thyristor controlled series capacitors |
ISO 10440-2:2001 | Petroleum and natural gas industries Rotary-type positive-displacement compressors Part 2: Packaged air compressors (oil-free) |
IEC 61180:2016 | High-voltage test techniques for low-voltage equipment - Definitions, test and procedure requirements, test equipment |
IEC 61083-1:2001 | Instruments and software used for measurement in high-voltage impulse tests - Part 1: Requirements for instruments |
EN 61009-1:2012/A12:2016 | RESIDUAL CURRENT OPERATED CIRCUIT-BREAKERS WITH INTEGRAL OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR USES (RCBOS) - PART 1: GENERAL RULES |
13/30288508 DC : 0 | BS IEC 60034-27-3 ED 1.0 - ROTATING ELECTRICAL MACHINES - PART 27-3: DIELECTRIC DISSIPATION FACTOR MEASUREMENT ON STATOR WINDING INSULATION OF ROTATING ELECTRICAL MACHINES |
11/30242675 DC : 0 | BS EN 60099-4 F2 - SURGE ARRESTERS - PART 4: METAL-OXIDE SURGE ARRESTERS WITHOUT GAPS FOR A.C. SYSTEMS |
BS EN IEC 60230:2018 | Impulse tests on cables and their accessories |
NFC 46 624 : 95 XP | EIBUS BUS: A NETWORK FOR TECHNICAL AND ADMINISTRATIVE MANAGEMENT OF BUILDINGS - PHYSICAL LAYER |
BS EN 60903:2003 | Live working. Gloves of insulating material |
14/30281166 DC : 0 | BS EN 50321 - LIVE WORKING - FOOTWEAR FOR ELECTRICAL PROTECTION - INSULATING FOOTWEAR AND OVERBOOTS |
BS 7922:2004 | Electric cables. Fluid-filled, paper- and PPL-insulated, metal-sheathed cables and accessories for alternating voltages up to and including 400 kV (<i>U</i><sub>m</sub> = 420 kV). Requirements and test methods |
11/30229950 DC : 0 | BS EN 61083-4 - DIGITAL RECORDERS FOR MEASUREMENTS IN HIGH CURRENT TESTING - PART 4: EVALUATION OF SOFTWARE USED FOR THE DETERMINATION OF PARAMETERS OF WAVEFORMS IN HIGH CURRENT TESTING "PROPOSED HORIZONTAL STANDARD" |
BS EN 60044-7:2000 | Instrument transformers Electronic voltage transformers |
BS EN 61051-1:2008 | Varistors for use in electronic equipment Generic specification |
CEI EN 60076-3 : 2015 | POWER TRANSFORMERS - PART 3: INSULATION LEVELS, DIELECTRIC TESTS AND EXTERNAL CLEARANCES IN AIR |
IEEE 400-2012 REDLINE | IEEE Guide for Field Testing and Evaluation of the Insulation of Shielded Power Cable Systems Rated 5 kV and Above |
BS IEC 61942:1997 | Live working. Gloves and mitts with mechanical protection |
CEI EN 61051-1 : 2010 | VARISTORS FOR USE IN ELECTRONIC EQUIPMENT - PART 1: GENERIC SPECIFICATION |
CEI EN 60358-3 : 2015 | COUPLING CAPACITORS AND CAPACITOR DIVIDERS - PART 3: AC OR DC COUPLING CAPACITORS FOR HARMONIC-FILTERS APPLICATIONS |
NF EN 60060-3 : 2006 | HIGH VOLTAGE TEST TECHNIQUES - PART 3: DEFINITIONS AND REQUIREMENTS FOR ON-SITE TESTS |
CSA ISO/IEC 8802-5 : 2002 : INC : UPD 1 : 2002 : R2011 | INFORMATION TECHNOLOGY - TELECOMMUNICATIONS AND INFORMATION EXCHANGE BETWEEN SYSTEMS - LOCAL AND METROPOLITAN AREA NETWORKS - SPECIFIC REQUIREMENTS - PART 5: TOKEN RING ACCESS METHOD AND PHYSICAL LAYER SPECIFICATIONS |
UNE-IEC/TS 62478:2017 | High voltage test techniques - Measurement of partial discharges by electromagnetic and acoustic methods |
08/30183914 DC : DRAFT JUNE 2008 | BS EN 60358-1 - COUPLING CAPACITORS AND CAPACITOR DIVIDERS - PART 1: COMMON CLAUSES |
BS EN 60099-9:2014 | Surge arresters Metal-oxide surge arresters without gaps for HVDC converter stations |
BS EN 61057:1994 | Aerial devices with insulating boom used for live working exceeding 1 kV a.c. |
11/30248499 DC : 0 | BS EN 61000-4-5 ED.3 - ELECTROMAGNETIC COMPATIBILITY - PART 4-5: TESTING AND MEASUREMENT TECHNIQUES - SURGE IMMUNITY TEST |
BS EN 61211:2005 | Insulators of ceramic material or glass for overhead lines with a nominal voltage greater than 1000 V. Impulse puncture testing in air |
11/30241356 DC : 0 | BS HD 60269-2 - LOW-VOLTAGE FUSES - PART 2: SUPPLEMENTARY REQUIREMENTS FOR FUSES FOR USE BY AUTHORIZED PERSONS (FUSES MAINLY FOR INDUSTRIAL APPLICATION) - EXAMPLES OF STANDARDIZED SYSTEMS OF FUSES A TO M |
PD IEC TR 61278:1997 | Live working. Guidelines for dielectric testing of tools and equipment |
CEI EN 61643-11 : 2014 | LOW-VOLTAGE SURGE PROTECTIVE DEVICES - PART 11: SURGE PROTECTIVE DEVICES CONNECTED TO LOW-VOLTAGE POWER SYSTEMS - REQUIREMENTS AND TEST METHODS |
BS EN 50321-1:2018 | Live working. Footwear for electrical protection Insulating footwear and overboots |
CEI EN 60060-1 : 2015 | HIGH-VOLTAGE TEST TECHNIQUES - PART 1: GENERAL DEFINITIONS AND TEST REQUIREMENTS |
I.S. EN 61009-1:2012 | RESIDUAL CURRENT OPERATED CIRCUIT-BREAKERS WITH INTEGRAL OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR USES (RCBOS) - PART 1: GENERAL RULES |
I.S. EN 60099-8:2011 | SURGE ARRESTERS - PART 8: METAL-OXIDE SURGE ARRESTERS WITH EXTERNAL SERIES GAP (EGLA) FOR OVERHEAD TRANSMISSION AND DISTRIBUTION LINES OF A.C. SYSTEMS ABOVE 1 KV |
CSA C22.2 No. 103 : 1992 : R2015 | ELECTRIC FENCE CONTROLLERS |
I.S. EN 61111:2009 | LIVE WORKING - ELECTRICAL INSULATING MATTING |
CSA C22.2 No. 103 : 1992 : R2010 | ELECTRIC FENCE CONTROLLERS |
I.S. EN 60060-3:2006 | HIGH VOLTAGE TEST TECHNIQUES - PART 3: DEFINITIONS AND REQUIREMENTS FOR ON-SITE TESTS |
I.S. EN 61180-2:1995 | HIGH VOLTAGE TEST TECHNIQUE FOR LOW-VOLTAGE EQUIPMENT - PART 2: TEST EQUIPMENT |
HD 60269-2-1:2005 | Low-voltage fuses - Part 2-1: Supplementary requirements for fuses for use by authorized persons (fuses mainly for industrial application) - Sections I to VI: Examples of types of standardized fuses |
CEI EN 60855-1 : 1ED 2017 | LIVE WORKING - INSULATING FOAM-FILLED TUBES AND SOLID RODS - PART 1: TUBES AND RODS OF A CIRCULAR CROSS-SECTION |
I.S. CECC 33000:1994 | PASSIVE FILTER UNITS FOR ELECTROMAGNETIC INTERFERENCE SUPPRESSION (GENERIC SPECIFICATION) |
I.S. EN 61180:2016 | HIGH-VOLTAGE TEST TECHNIQUES FOR LOW-VOLTAGE EQUIPMENT - DEFINITIONS, TEST AND PROCEDURE REQUIREMENTS, TEST EQUIPMENT |
I.S. EN 61643-21:2001 | LOW VOLTAGE SURGE PROTECTIVE DEVICES - PART 21: SURGE PROTECTIVE DEVICES CONNECTED TO TELECOMMUNICATIONS AND SIGNALLING NETWORKS - PERFORMANCE REQUIREMENTS AND TESTING METHODS (IEC 61643-21:2000 (EQV) + CORRIGENDUM MAR. 2001 (EQV)) |
IEC TS 62561-8:2018 | Lightning protection system components (LPSC) - Part 8: Requirements for components for isolated LPS |
I.S. EN 61112:2009 | LIVE WORKING - ELECTRICAL INSULATING BLANKETS |
I.S. EN 60903:2003 | LIVE WORKING - GLOVES OF INSULATING MATERIAL |
I.S. EN 62237:2005 | LIVE WORKING - INSULATING HOSES WITH FITTINGS FOR USE WITH HYDRAULIC TOOLS AND EQUIPMENT |
I.S. EN 60060-1:2010 | HIGH-VOLTAGE TEST TECHNIQUES - PART 1: GENERAL DEFINITIONS AND TEST REQUIREMENTS |
IEC TS 60034-27:2006 | Rotating electrical machines - Part 27: Off-line partial discharge measurements on the stator winding insulation of rotating electrical machines |
IEC 61057:2017 | Live working - Insulating aerial devices for mounting on a chassis |
IEC 60034-27-1:2017 | Rotating electrical machines - Part 27-1: Off-line partial discharge measurements on the winding insulation |
IEC 62955:2018 | Residual direct current detecting device (RDC-DD) to be used for mode 3 charging of electric vehicles |
IEC 61942:1997 | Live working - Gloves and mitts with mechanical protection |
IEC 61009-1:2010+AMD1:2012+AMD2:2013 CSV | Residual current operated circuit-breakers with integral overcurrentprotection for household and similar uses (RCBOs) - Part 1: General rules |
EN 60358-1:2012 | COUPLING CAPACITORS AND CAPACITOR DIVIDERS - PART 1: GENERAL RULES (IEC 60358-1:2012) |
IEC 60076-4:1976 | Power transformers - Part 4: Tappings and connections |
IEC 61479:2001+AMD1:2002 CSV | Live working - Flexible conductor covers (line hoses) of insulating material |
12/30266531 DC : 0 | BS EN TS 62257-1 - RECOMMENDATIONS FOR SMALL RENEWABLE ENERGY AND HYBRID SYSTEMS FOR RURAL ELECTRIFICATION - PART 1: GENERAL INTRODUCTION TO RURAL ELECTRIFICATION |
IEC TS 63053:2017 | General requirements for residual current operated protective devices for DC system |
IEC 61112:2009 | Live working - Electrical insulating blankets |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 60052:2002 | Voltage measurement by means of standard air gaps |
IEC 60358-2:2013 | Coupling capacitors and capacitor dividers - Part 2: AC or DC single-phase coupling capacitor connected between line and ground for power line carrier-frequency (PLC) application |
IEC 60831-1:2014 RLV | Shunt power capacitors of the self-healing type for a.c. systems having a rated voltage up to and including 1 000 V - Part 1: General - Performance, testing and rating - Safety requirements - Guide for installation and operation |
IEC 61211:2004 | Insulators of ceramic material or glass for overhead lines with a nominal voltage greater than 1 000 V - Impulse puncture testing in air |
IEC 62271-106:2011 | High-voltage switchgear and controlgear - Part 106: Alternating current contactors, contactor-based controllers and motor-starters |
UNE-EN 61009-1:2013 | Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBOs) - Part 1: General rules |
IEC 60099-9:2014 | Surge arresters - Part 9: Metal-oxide surge arresters without gaps for HVDC converter stations |
IEC 61954:2011+AMD1:2013+AMD2:2017 CSV | Static var compensators (SVC) - Testing of thyristor valves |
IEC 62237:2003 | Live working - Insulating hoses with fittings for use with hydraulic tools and equipment |
IEC 60099-4:2014 | Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems |
IEC 60358-3:2013 | Coupling capacitors and capacitor dividers - Part 3: AC or DC coupling capacitor for harmonic-filters applications |
IEC 60269-2-1:2004 | Low-voltage fuses - Part 2-1: Supplementary requirements for fuses for use by authorized persons (fuses mainly for industrial application) - Sections I to VI: Examples of types of standardized fuses |
IEC 60358-1:2012 | Coupling capacitors and capacitor dividers - Part 1: General rules |
IEC 61083-2:2013 | Instruments and software used for measurement in high-voltage and high-current tests - Part 2: Requirements for software for tests with impulse voltages and currents |
IEC 60060-3:1976 | High-voltage test techniques - Part 3: Measuring devices |
IEC 60310:2016 | Railway applications - Traction transformers and inductors on board rolling stock |
IEC 60855-1:2016 | Live working - Insulating foam-filled tubes and solid rods - Part 1: Tubes and rods of a circular cross-section |
BS EN 61009-1 : 2012 | RESIDUAL CURRENT OPERATED CIRCUIT-BREAKERS WITH INTEGRAL OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR USES (RCBOS) - PART 1: GENERAL RULES |
UNE-EN 62271-106:2012 | High-voltage switchgear and controlgear - Part 106: Alternating current contactors, contactor-based controllers and motor-starters |
EN ISO 10440-2:2001 | Petroleum and natural gas industries - Rotary-type positive-displacement compressors - Part 2: Packaged air compressors (oil-free) (ISO 10440-2:2001) |
I.S. EN 60076-3:2013 | POWER TRANSFORMERS - PART 3: INSULATION LEVELS, DIELECTRIC TESTS AND EXTERNAL CLEARANCES IN AIR |
IEEE 400.4-2015 | IEEE Guide for Field Testing of Shielded Power Cable Systems Rated 5 kV and Above with Damped Alternating Current (DAC) Voltage |
UNE-EN 60060-1:2012 | High-voltage test techniques - Part 1: General definitions and test requirements |
BS CECC 42000:1978 | Harmonized system of quality assessment for electronic components: generic specification: varistors |
BS EN 60060-3:2006 | High voltage test techniques Definitions and requirements for on-site tests |
CLC/TS 60034-27:2011 | Rotating electrical machines - Part 27: Off-line partial discharge measurements on the stator winding insulation of rotating electrical machines |
S.R. CLC/TS 60034-27:2011 | ROTATING ELECTRICAL MACHINES - PART 27: OFF-LINE PARTIAL DISCHARGE MEASUREMENTS ON THE STATOR WINDING INSULATION OF ROTATING ELECTRICAL MACHINES |
IEC 60076-3-1:1987 | Power transformers. Part 3: Insulation levels and dielectric tests - External clearances in air |
CSA C22.2 No. 103 : 1992 : R2005 | ELECTRIC FENCE CONTROLLERS |
PD IEC/TS 62478:2016 | High voltage test techniques. Measurement of partial discharges by electromagnetic and acoustic methods |
BS EN 60143-1:2015 | Series capacitors for power systems General |
EN 61954:2011/A2:2017 | STATIC VAR COMPENSATORS (SVC) - TESTING OF THYRISTOR VALVES (IEC 61954:2011/A2:2017) |
NF EN 50321 : 2000 | ELECTRICALLY INSULATING FOOTWEAR FOR WORKING ON LOW VOLTAGE INSTALLATIONS |
I.S. EN 62271-106:2011 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 106: ALTERNATING CURRENT CONTACTORS, CONTACTOR-BASED CONTROLLERS AND MOTOR-STARTERS (IEC 62271-106:2011 (EQV)) |
BS EN 61000-4-5:2014 | Electromagnetic compatibility (EMC) Testing and measurement techniques. Surge immunity test |
UNE-EN 61180:2017 | High-voltage test techniques for low-voltage equipment - Definitions, test and procedure requirements, test equipment |
BS EN 60143 : 1993 AMD 8725 | SERIES CAPACITORS FOR POWER SYSTEMS |
BS EN 60358-2:2013 | Coupling capacitors and capacitor dividers AC or DC single-phase coupling capacitor connected between line and ground for power line carrier-frequency (PLC) application |
IEEE C62.33-1982 | IEEE Standard Test Specifications for Varistor Surge-Protective Devices |
PD CISPR/TR 18-2:2017 | Radio interference characteristics of overhead power lines and high-voltage equipment Part 2: Methods of measurement and procedure for determining limits |
05/30128254 DC : DRAFT JAN 2005 | IEC 60034-27 - ROTATING ELECTRICAL MACHINES - PART 27: PARTIAL DISCHARGE OFF-LINE MEASUREMENTS ON THE STATOR WINDING INSULATION OF ROTATING MACHINERY |
16/30345685 DC : 0 | BS EN 60358-4 - COUPLING CAPACITORS AND CAPACITOR DIVIDERS - PART 4: DC AND AC SINGLE-PHASE CAPACITOR DIVIDERS |
BS EN 60034-27-3:2016 | Rotating electrical machines Dielectric dissipation factor measurement on stator winding insulation of rotating electrical machines |
NF EN 61479 : 2001 AMD 1 2003 | LIVE WORKING - FLEXIBLE CONDUCTOR COVERS (LINE HOSES) OF INSULATING MATERIAL |
CSA C411.1 : 2016 | AC SUSPENSION INSULATORS |
DD CLC/TS 60034-27:2011 | Rotating electrical machines Off-line partial discharge measurements on the stator winding insulation of rotating electrical machines |
98/230636 DC : DRAFT MARCH 98 | DRAFT IEC 61010-2-031 - SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT CONTROL AND LABORATORY USE 2-031: SAFETY REQUIREMENTS FOR HAND-HELD PROBE ASSEMBLIES FOR ELECTRICAL MEASUREMENT TEST |
NF EN 61111 : 2009 | LIVE WORKING - ELECTRICAL INSULATING MATTING |
BS EN 62237:2005 | Live working. Insulating hoses with fittings for use with hydraulic tools and equipment |
BS EN 61643-11 : 2012 | LOW-VOLTAGE SURGE PROTECTIVE DEVICES - PART 11: SURGE PROTECTIVE DEVICES CONNECTED TO LOW-VOLTAGE POWER SYSTEMS - REQUIREMENTS AND TEST METHODS |
IEC TS 62478:2016 | High voltage test techniques - Measurement of partial discharges by electromagnetic and acoustic methods |
CEI EN 62237 : 2006 | LIVE WORKING - INSULATING HOSES WITH FITTINGS FOR USE WITH HYDRAULIC TOOLS AND EQUIPMENT |
09/30190333 DC : 0 | BS EN 61400-24 - WIND TURBINES - PART 24: LIGHTNING PROTECTION |
NF EN 60099-8 : 2011 | SURGE ARRESTERS - PART 8: METAL-OXIDE SURGE ARRESTERS WITH EXTERNAL SERIES GAP (EGLA) FOR OVERHEAD TRANSMISSION AND DISTRIBUTION LINES OF A.C. SYSTEMS ABOVE 1 KV |
BIS IS 12640-1 : 2008 | RESIDUAL CURRENT OPERATED CIRCUIT-BREAKERS FOR HOUSEHOLD AND SIMILAR USES - PART 1: CIRCUIT-BREAKERS WITHOUT INTEGRAL OVERCURRENT PROTECTION (RCCBS) |
DIN IEC 60060-1 : 1994 | HIGH VOLTAGE TEST TECHNIQUES - GENERAL SPECIFICATIONS AND TEST REQUIREMENTS |
CSA C156.3 : 1986 : R2004 | TEST METHODS FOR STATION POST INSULATORS |
CSA ISO/IEC 8802-5 : 2002 : INC : AMD 1 : 2002 : R2011 | INFORMATION TECHNOLOGY - TELECOMMUNICATIONS AND INFORMATION EXCHANGE BETWEEN SYSTEMS - LOCAL AND METROPOLITAN AREA NETWORKS - SPECIFIC REQUIREMENTS - PART 5: TOKEN RING ACCESS METHOD AND PHYSICAL LAYER SPECIFICATIONS |
EN 62271-106:2011 | High-voltage switchgear and controlgear - Part 106: Alternating current contactors, contactor-based controllers and motor-starters |
IEEE 45.6-2016 | IEEE Recommended Practice for Electrical Installations on Shipboard--Electrical Testing |
BS EN 60076-3 : 2013 | POWER TRANSFORMERS - PART 3: INSULATION LEVELS, DIELECTRIC TESTS AND EXTERNAL CLEARANCES IN AIR |
ETR 087 : 20001 | BUSINESS TELECOMMUNICATIONS (BT) - OPEN NETWORK PROVISION (ONP) TECHNICAL REQUIREMENTS; STANDARDISATION REQUIREMENTS FOR ONP LEASED LINES - HIGHER ORDER LEASED LINES |
IEEE 1894-2015 | IEEE Guide for Online Monitoring and Recording Systems for Transient Overvoltages in Electric Power Systems |
I.S. HD 60269-2:2013 | LOW-VOLTAGE FUSES - PART 2: SUPPLEMENTARY REQUIREMENTS FOR FUSES FOR USE BY AUTHORIZED PERSONS (FUSES MAINLY FOR INDUSTRIAL APPLICATION) - EXAMPLES OF STANDARDIZED SYSTEMS OF FUSES A TO K (IEC 60269-2:2013 (MOD)) |
I.S. EN 60855-1:2017 | LIVE WORKING - INSULATING FOAM-FILLED TUBES AND SOLID RODS - PART 1: TUBES AND RODS OF A CIRCULAR CROSS-SECTION |
I.S. EN 60099-9:2014 | SURGE ARRESTERS - PART 9: METAL-OXIDE SURGE ARRESTERS WITHOUT GAPS FOR HVDC CONVERTER STATIONS |
I.S. EN 60143-1:2015 | SERIES CAPACITORS FOR POWER SYSTEMS - PART 1: GENERAL |
CEI EN 60099-9 : 2015 | SURGE ARRESTERS - PART 9: METAL-OXIDE SURGE ARRESTERS WITHOUT GAPS FOR HVDC CONVERTER STATIONS |
BS EN 62606:2013 | General requirements for arc fault detection devices |
I.S. EN 50463:2007 | RAILWAY APPLICATIONS - ENERGY MEASUREMENT ON BOARD TRAINS |
I.S. EN 60358-2:2013 | COUPLING CAPACITORS AND CAPACITOR DIVIDERS - PART 2: AC OR DC SINGLE-PHASE COUPLING CAPACITOR CONNECTED BETWEEN LINE AND GROUND FOR POWER LINE CARRIER-FREQUENCY (PLC) APPLICATION |
CSA C22.2 No. 103 : 1992 : R2010 : FR | ELECTRIC FENCE CONTROLLERS |
BS EN 60099-4:2014 | Surge arresters Metal-oxide surge arresters without gaps for a.c. systems |
CISPR TR 18-2:2017 | Radio interference characteristics of overhead power lines and high-voltage equipment - Part 2: Methods of measurement and procedure for determining limits |
GOST R IEC 60384-14 : 2004 | FIXED CAPACITORS FOR USE IN ELECTRONIC EQUIPMENT - PART 14 - SECTIONAL SPECIFICATION ON FIXED CAPACITORS FOR ELECTROMAGNETIC INTERFERENCE SUPPRESSION AND CONNECTION TO THE SUPPLY MAINS |
I.S. EN 61083-2:2013 | INSTRUMENTS AND SOFTWARE USED FOR MEASUREMENT IN HIGH-VOLTAGE AND HIGH-CURRENT TESTS - PART 2: REQUIREMENTS FOR SOFTWARE FOR TESTS WITH IMPULSE VOLTAGES AND CURRENTS (IEC 61083-2:2013 (EQV)) |
BIS IS 13774 : 2014 | LIVE WORKING - GLOVES OF INSULATING MATERIAL |
CEI EN 60099-8 : 2012 | SURGE ARRESTERS - PART 8: METAL-OXIDE SURGE ARRESTERS WITH EXTERNAL SERIES GAP (EGLA) FOR OVERHEAD TRANSMISSION AND DISTRIBUTION LINES OF A.C. SYSTEMS ABOVE 1 KV |
IEC 61643-11:2011 | Low-voltage surge protective devices - Part 11: Surge protective devices connected to low-voltage power systems - Requirements and test methods |
IEC 60270:2000+AMD1:2015 CSV | High-voltage test techniques - Partial discharge measurements |
IEC 61111:2009 | Live working - Electrical insulating matting |
EN 61643-21:2001/A2:2013 | LOW VOLTAGE SURGE PROTECTIVE DEVICES - PART 21: SURGE PROTECTIVE DEVICES CONNECTED TO TELECOMMUNICATIONS AND SIGNALLING NETWORKS - PERFORMANCE REQUIREMENTS AND TESTING METHODS (IEC 61643-21:2000/A2:2012) |
EN 132400 : 1994 AMD 4 2001 | SECTIONAL SPECIFICATION: FIXED CAPACITORS FOR ELECTROMAGNETIC INTERFERENCE SUPPRESSION AND CONNECTION TO THE SUPPLY MAINS (ASSESSMENT LEVEL D) |
EN 60358-2:2013 | Coupling capacitors and capacitor dividers - Part 2: AC or DC single-phase coupling capacitor connected between line and ground for power line carrier-frequency (PLC) application |
EN 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
EN 60076-4:2002 | Power transformers - Part 4: Guide to the lightning impulse and switching impulse testing - Power transformers and reactors |
EN 60099-9:2014 | Surge arresters - Part 9: Metal-oxide surge arresters without gaps for HVDC converter stations |
EN 60143-4 : 2010 | SERIES CAPACITORS FOR POWER SYSTEMS - PART 4: THYRISTOR CONTROLLED SERIES CAPACITORS |
EN 62237:2005 | Live working - Insulating hoses with fittings for use with hydraulic tools and equipment |
HD 60269-2:2013 | Low-voltage fuses - Part 2: Supplementary requirements for fuses for use by authorized persons (fuses mainly for industrial application) - Examples of standardized systems of fuses A to K |
EN 61211:2005 | Insulators of ceramic material or glass for overhead lines with a nominal voltage greater than 1 000 V - Impulse puncture testing in air |
EN 50463:2007 | Railway applications - Energy measurement on board trains |
EN 60903 : 2003 COR 2005 | LIVE WORKING - GLOVES OF INSULATING MATERIAL |
IEC 60099-8:2017 RLV | Surge arresters - Part 8: Metal-oxide surge arresters with external series gap (EGLA) for overhead transmission and distribution lines of a.c. systems above 1 kV |
EN 60310:2016/AC:2018-03 | RAILWAY APPLICATIONS - TRACTION TRANSFORMERS AND INDUCTORS ON BOARD ROLLING STOCK (IEC 60310:2016/COR1:2018) |
EN 60855-1:2017 | Live working - Insulating foam-filled tubes and solid rods - Part 1: Tubes and rods of a circular cross-section |
EN 60076-3:2013/A1:2018 | POWER TRANSFORMERS - PART 3: INSULATION LEVELS, DIELECTRIC TESTS AND EXTERNAL CLEARANCES IN AIR (IEC 60076-3:2013/A1:2018) |
EN 60358-3:2014 | Coupling capacitors and capacitor dividers - Part 3: AC or DC coupling capacitors for harmonic-filters applications |
BS 4944(1994) : 1994 AMD 8405 | REACTORS |
ISO/IEC 17025:2005 | General requirements for the competence of testing and calibration laboratories |
IEC 60270:2000+AMD1:2015 CSV | High-voltage test techniques - Partial discharge measurements |
IEC 62475:2010 | High-current test techniques - Definitions and requirements for test currents and measuring systems |
IEC 60060-3:1976 | High-voltage test techniques - Part 3: Measuring devices |
IEC 60051:1973 | Recommendations for direct acting indicating electrical measuring instruments and their accessories |
IEC 60050-321:1986 | International Electrotechnical Vocabulary (IEV) - Part 321: Instrument transformers |
IEC 60052:2002 | Voltage measurement by means of standard air gaps |
IEC 61083-2:2013 | Instruments and software used for measurement in high-voltage and high-current tests - Part 2: Requirements for software for tests with impulse voltages and currents |
AS/NZS IEC 61111:2020 | Live working - Electrical insulating mats |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 60071-1:2006+AMD1:2010 CSV | Insulation co-ordination - Part 1: Definitions, principles and rules |
IEC 61083-1:2001 | Instruments and software used for measurement in high-voltage impulse tests - Part 1: Requirements for instruments |
IEC 60050-300:2001 | International Electrotechnical Vocabulary (IEV) - Part 300: Electrical and electronic measurements and measuring instruments - Part 311: General terms relating to measurements - Part 312: General terms relating to electrical measurements - Part 313: Types of electrical measuring instruments - Part 314: Specific terms according to the type of instrument |
ISO/IEC Guide 98-3:2008 | Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.