FOREWORD
1 General
1.1 Scope
1.2 Normative references
2 Normal and special service conditions
2.1 Normal service conditions
2.2 Special service conditions
3 Definitions
3.1 General terms
3.2 Assemblies of switchgear and controlgear
3.3 Parts of assemblies
3.4 Switching devices
3.5 Parts of switchgear and controlgear
3.6 Operation
3.7 Characteristic quantities
3.8 Index of definitions
4 Ratings
4.1 Rated voltages (U[r])
4.2 Rated insulation level
4.3 Rated frequency (f[r])
4.4 Rated normal current and temperature rise
4.5 Rated short-time withstand current (l[k])
4.6 Rated peak withstand current (l[p])
4.7 Rated duration of short circuit (t[k])
4.8 Rated supply frequency of closing and opening
devices and of auxiliary circuits (U[a])
4.9 Rated supply frequency of closing and opening
devices and of auxiliary circuits
4.10 Rated pressure of compressed gas supply for
insulation and/or operation
5 Design and construction
5.1 Requirements for liquids in switchgear and
controlgear
5.2 Requirements for gases in switchgear and
controlgear
5.3 Earthing of switchgear and controlgear
5.4 Auxiliary and control equipment
5.5 Dependent power operation
5.6 Stored energy operation
5.7 Independent manual operation
5.8 Operation of releases
5.9 Low- and high-pressure interlocking and
monitoring devices
5.10 Nameplates
5.11 Interlocking devices
5.12 Position indication
5.13 Degrees of protection by enclosures
5.14 Creepage distances
5.15 Gas and vacuum tightness
5.16 Liquid tightness
5.17 Flammability
5.18 Electromagnetic compatibility (EMC)
6 Type tests
6.1 General
6.2 Dielectric tests
6.3 Radio interference voltage (r.i.v.) test
6.4 Measurement of the resistance of circuits
6.5 Temperature-rise tests
6.6 Short-time withstand current and peak withstand
current tests
6.7 Verification of the protection
6.8 Tightness tests
6.9 Electromagnetic compatibility tests (EMC)
6.10 Additional tests on auxiliary and control circuits
7 Routine tests
7.1 Dielectric test on the main circuit
7.2 Dielectric test on auxiliary and control circuit
7.3 Measurement of the resistance of the main
circuit
7.4 Tightness test
7.5 Design and visual checks
8 Guide to the selection of switchgear and controlgear
9 Information to be given with enquiries, tenders and
offers
10 Rules for transport, storage, installation, operation
and maintenance
10.1 Conditions during transport, storage and
installation
10.2 Installation
10.3 Operation
10.4 Maintenance
11 Safety
11.1 Electrical aspects
11.2 Mechanical aspects
11.3 Thermal aspects
11.4 Operation aspects
Annex A (normative) Identification of test specimens
Annex B (normative) Determination of the equivalent
r.m.s. value of a short-time current during a
short circuit of a given duration
Annex C (normative) Method for the weatherproofing test
for outdoor switchgear and controlgear
Annex D (informative) Information about insulation
levels and tests
Annex E (informative) Tightness (information, example
and guidance)
Annex F (informative) Dielectric testing of self-protected
switchgear and controlgear
Annex G (informative) Bibliography
Annex H (informative) Electromagnetic compatibility
site measurements
Applies, unless otherwise specified in relevant IEC standards, to all a.c. high-voltage switchgear and controlgear designed for indoor or outdoor installation, for operation at service frequencies up to and including 60 Hz, on systems having voltages above 1000 V. The contents of the corrigenda of January 2001 and December 2001 have been included in this copy. This consolidated version consists of the second edition (1996), its amendment 1 (2000) and its amendment 2 (2001). Therefore, no need to order amendments in addition to this publication.
Committee |
TC 17/SC 17A
|
DevelopmentNote |
Also numbered as BS EN 60694. (12/2005)
|
DocumentType |
Standard
|
Pages |
225
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
NF EN 60694 : 96 AMD 2 2002 | Identical |
NEN EN IEC 60694 : 96 C1 2002 | Identical |
NEN 10694 : 1996 | Identical |
I.S. EN 60694:1999 | Identical |
PN EN 60694 : 2004 | Identical |
SN EN 60694 : 1996 AMD 2 2001 | Identical |
VDE 0670-1000 : 2002 | Identical |
DIN EN 60694 : 2002 | Identical |
BIS IS 12729 : 2004 | Identical |
CEI 17-21 : 1986 COR 1990 | Identical |
EN 60694:1996/A2:2001 | Similar to |
CEI EN 60694 : 1997/A1/A2 : 2002 | Identical |
UNE-EN 60694:1998 | Identical |
BS 6581:1985 | Identical |
I.S. EN 62271-2:2003 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - SEISMIC QUALIFICATION FOR RATED VOLTAGES OF 72,5 KV AND ABOVE |
CEI EN 61462 : 2008 | COMPOSITE HOLLOW INSULATORS - PRESSURIZED AND UNPRESSURIZED INSULATORS FOR USE IN ELECTRICAL EQUIPMENT WITH RATED VOLTAGE GREATER THAN 1000 V - DEFINITIONS, TEST METHODS, ACCEPTANCE CRITERIA AND DESIGN RECOMMENDATIONS |
BS EN 61869-1:2009 | Instrument transformers General requirements |
BS EN 60298:1996 | A.C. metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV |
CEI 32-10 : 2001 | GUIDANCE CONCERNING THE PERMISSIBLE TEMPERATURE RISE FOR PARTS OF ELECTRICAL EQUIPMENT, IN PARTICULAR FOR TERMINALS |
02/210916 DC : DRAFT OCT 2002 | IEC 62271-002 - HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 002: SEISMIC QUALIFICATION FOR RATED VOLTAGES OF 72,5 KV AND ABOVE |
IEEE C37.016-2006 | IEEE Standard for AC High Voltage Circuit Switchers rated 15.5kV through 245kV |
CEI EN 60376 : 2006 | SPECIFICATION OF TECHNICAL GRADE SULFUR HEXAFLUORIDE (SF[6]) FOR USE IN ELECTRICAL EQUIPMENT |
I.S. EN 61000-4-18:2007 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-18: TESTING AND MEASUREMENT TECHNIQUES - DAMPED OSCILLATORY WAVE IMMUNITY TEST |
BS EN 50123-7-3:2003 | Railway applications. Fixed installations. d.c. switchgear. Measurement, control and protection devices for specific use in d.c. traction systems Isolating voltage transducers and other voltage measuring devices |
I.S. EN 62271-108:2006 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 108: HIGH-VOLTAGE ALTERNATING CURRENT DISCONNECTING CIRCUIT-BREAKERS FOR RATED VOLTAGES OF 72,5 KV AND ABOVE |
97/208495 DC : DRAFT JUL 1997 | IEC 61640 - HV GAS-INSULATED TRANSMISSION LINES FOR RATED VOLTAGES OF 72,5 KV AND ABOVE |
04/30092537 DC : DRAFT APR 2004 | IEC 62271-108 - HIGH-VOLTAGE SWITCHGEAR AND CONTROL GEAR - PART 108: COMBINED FUNCTION DISCONNECTING CIRCUIT-BREAKERS |
BS EN 61958:2001 | High-voltage prefabricated switchgear and controlgear assemblies. Voltage presence indicating systems |
CSA C62155 : 2006 : R2015 | HOLLOW PRESSURIZED AND UNPRESSURIZED CERAMIC AND GLASS INSULATORS FOR USE IN ELECTRICAL EQUIPMENT WITH RATED VOLTAGES GREATER THAN 1000 V |
05/30136204 DC : DRAFT JUL 2005 | |
CSA C60044-5:2007 | INSTRUMENT TRANSFORMERS - PART 5: CAPACITOR VOLTAGE TRANSFORMERS |
I.S. EN 50123-1:2003 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - GENERAL |
I.S. EN 50123-4:2003 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 4: OUTDOOR D.C. DISCONNECTORS, SWITCH-DISCONNECTORS AND EARTHING SWITCHES |
CSA C60044-5 : 2007 : R2011 | INSTRUMENT TRANSFORMERS - PART 5: CAPACITOR VOLTAGE TRANSFORMERS |
I.S. EN 60044-8:2002 | INSTRUMENT TRANSFORMERS - PART 8: ELECTRONIC CURRENT TRANSFORMERS |
CSA C60044-8 : 2007 : R2016 | INSTRUMENT TRANSFORMERS - PART 8: ELECTRONIC CURRENT TRANSFORMERS |
IEEE 525-2007 | IEEE Guide for the Design and Installation of Cable Systems in Substations |
CEI EN 50508 : 2009 | MULTI-PURPOSE INSULATING STICKS FOR ELECTRICAL OPERATIONS ON HIGH VOLTAGE INSTALLATIONS |
I.S. EN 62155:2003 | HOLLOW PRESSURIZED AND UNPRESSURIZED CERAMIC AND GLASS INSULATORS FOR USE IN ELECTRICAL EQUIPMENT WITH RATED VOLTAGES GREATER THAN 1000 V |
CEI EN 60282-1 : 2011 | HIGH-VOLTAGE FUSES - PART 1: CURRENT-LIMITING FUSES |
BS EN 62271-209:2007 | High-voltage switchgear and controlgear Cable connections for gas-insulated metal-enclosed switchgear for rated voltages above 52 kV. Fluid-filled and extruded insulation cables. Fluid-filled and dry-type cable-terminations |
CSA C1264 : 0 | CERAMIC PRESSURIZED HOLLOW INSULATORS FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR |
GOST R IEC 61850-3 : 2005 | COMMUNICATION NETWORKS AND SYSTEMS IN SUBSTATIONS - PART 3 - GENERAL REQUIREMENTS |
I.S. EN 61958:2001 | HIGH-VOLTAGE PREFABRICATED SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - VOLTAGE PRESENCE INDICATING SYSTEMS |
IEC 61992-3:2006+AMD1:2015 CSV | Railway applications - Fixed installations - DC switchgear - Part 3:Indoor d.c. disconnectors, switch-disconnectors and earthing switches |
EN 62271-209:2007 | High-voltage switchgear and controlgear - Part 209: Cable connections for gas-insulated metal-enclosed switchgear for rated voltages above 52 kV - Fluid-filled and extruded insulation cables - Fluid-filled and dry-type cable-terminations |
EN 62155:2003 | Hollow pressurized and unpressurized ceramic and glass insulators for use in electrical equipment with rated voltages greater than 1 000 V |
EN 60376:2005 | Specification of technical grade sulfur hexafluoride (SF6) for use in electrical equipment |
EN 60204-11:2000/corrigendum:2010 | SAFETY OF MACHINERY - ELECTRICAL EQUIPMENT OF MACHINES - PART 11: REQUIREMENTS FOR HV EQUIPMENT FOR VOLTAGES ABOVE 1000 V A.C. OR 1500 V D.C. AND NOT EXCEEDING 36 KV |
NF EN 60077-4 : 2003 | RAILWAY APPLICATIONS - ELECTRIC EQUIPMENT FOR ROLLING STOCK - PART 4: ELECTROTECHNICAL COMPONENTS - RULES FOR AC CIRCUIT-BREAKERS |
EN 60298:1996/A11:1999 | A.C. METAL-ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV |
EN 60265-2:1993/A2:1998 | HIGH-VOLTAGE SWITCHES - HIGH-VOLTAGE SWITCHES FOR RATED VOLTAGES OF 52 KV AND ABOVE |
EN 62271-102:2002/AC:2014 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 102: ALTERNATING CURRENT DISCONNECTORS AND EARTHING SWITCHES (IEC 62271-102:2001/A2:2013) |
NF EN 62271-209 : 2008 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 209: CABLE CONNECTIONS FOR GAS-INSULATED METAL-ENCLOSED SWITCHGEAR FOR RATED VOLTAGES ABOVE 52 KV - FLUID-FILLED AND EXTRUDED INSULATION CABLES - FLUID-FILLED AND DRY TYPE CABLE-TERMINATIONS |
04/30111589 DC : 0 | |
I.S. EN 60480:2005 | GUIDELINES FOR CHECKING AND TREATMENT OF SULPHUR HEXAFLUORIDE (SF[6]) TAKEN FROM ELECTRICAL EQUIPMENT AND SPECIFICATION FOR ITS RE-USE |
NF EN 60480 : 2005 | GUIDELINES FOR THE CHECKING AND TREATMENT OF SULPHUR HEXAFLUORIDE (SF6) TAKEN FROM ELECTRICAL EQUIPMENT AND SPECIFICATION FOR ITS RE-USE |
BS EN 62155:2003 | Hollow pressurized and unpressurized ceramic and glass insulators for use in electrical equipment with rated voltages greater than 1000 V |
NF EN 61869-1 : 2009 | INSTRUMENT TRANSFORMERS - PART 1: GENERAL REQUIREMENTS |
PD IEC/TR 60943:2009 | Guidance concerning the permissible temperature rise for parts of electrical equipment, in particular for terminals |
BS EN 61462:2007 | Composite hollow insulators. Pressurized and unpressurized insulators for use in electrical equipment with rated voltage greater than 1000 V. Definitions, test methods, acceptance criteria and design recommendations |
BS EN 45510-2-7:2002 | Guide for the procurement of power station equipment. Electrical equipment Switchgear and controlgear |
09/30196635 DC : 0 | BS EN 60092-510 - ELECTRICAL INSTALLATIONS IN SHIPS - SPECIAL FEATURES - HIGH VOLTAGE SHORE CONNECTION SYSTEMS (HVSC-SYSTEMS) |
CEI EN 60265-1 : 2000 | INTERRUPTEURS A HAUTE TENSION - PARTIE 1: INTERRUPTEURS POUR TENSIONS ASSIGNEES SUPERIEURES A 1 KV ET INFERIEURES A 52 KV |
I.S. EN 61462:2007 | COMPOSITE HOLLOW INSULATORS - PRESSURIZED AND UNPRESSURIZED INSULATORS FOR USE IN ELECTRICAL EQUIPMENT WITH RATED VOLTAGE GREATER THAN 1 000 V - DEFINITIONS, TEST METHODS, ACCEPTANCE CRITERIA AND DESIGN RECOMMENDATIONS |
CEI EN 62155 : 2004 | HOLLOW PRESSURIZED AND UNPRESSURIZED CERAMIC AND GLASS INSULATORS FOR USE IN ELECTRICAL EQUIPMENT WITH RATED VOLTAGES GREATER THAN 1000 V |
IEEE DRAFT C37.60 : D10 SEP 2000 | DRAFT STANDARD REQUIREMENTS FOR OVERHEAD, PAD MOUNTED, DRY VAULT, AND SUBMERSIBLE AUTOMATIC CIRCUIT RECLOSERS AND FAULT INTERRUPTERS FOR AC SYSTEMS |
NF EN 62155 : 2003 | HOLLOW PRESSURIZED AND UNPRESSURIZED CERAMIC AND GLASS INSULATORS FOR USE IN ELECTRICAL EQUIPMENT WITH RATED VOLTAGES GREATER THAN 1000 V |
BS EN 60077-4:2003 | Railway applications. Electric equipment for rolling stock Electrotechnical components. Rules for AC circuit-breakers |
BS EN 50508:2009 | Multi-purpose insulating sticks for electrical operations on high voltage installations |
IEC PAS 60092-510:2009 | Electrical installations in ships - Part 510: Special features - High-voltage shore connection systems |
CEI EN 62271-209 : 2009 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 209: CABLE CONNECTIONS FOR GAS-INSULATED METAL-ENCLOSED SWITCHGEAR FOR RATED VOLTAGES ABOVE 52 KV - FLUID-FILLED AND EXTRUDED INSULATION CABLES - FLUID-FILLED AND DRY-TYPE CABLE-TERMINATIONS |
BS EN 60265-2:1994 | Specification for high-voltage switches Specification for high-voltage switches. High-voltage switches for rated voltages of 52 kV and above |
CSA C62155:2006 | HOLLOW PRESSURIZED AND UNPRESSURIZED CERAMIC AND GLASS INSULATORS FOR USE IN ELECTRICAL EQUIPMENT WITH RATED VOLTAGES GREATER THAN 1000 V |
CEI UNI EN 45510-2-7 : 2006 | GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-7: ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR |
98/232755 DC : DRAFT DEC 1998 | IEC 61936-1 - POWER INSTALLATIONS EXCEEDING 1 KV A.C. - PART 1: COMMON RULES |
04/30092543 DC : DRAFT MAR 2004 | |
EN 50123-7-2:2003 | Railway applications - Fixed installations - D.C. switchgear - Part 7-2: Measurement, control and protection devices for specific use in d.c. traction systems - Isolating current transducers and other current measuring devices |
CSA C60044-8 : 2007 : R2011 | INSTRUMENT TRANSFORMERS - PART 8: ELECTRONIC CURRENT TRANSFORMERS |
IEEE C37.100.1-2007 | IEEE Standard of Common Requirements for High Voltage Power Switchgear Rated Above 1000 V |
BS EN 60044-8:2002 | Instrument transformers Electronic current transformers |
BS EN 50123-1:2003 | Railway applications. Fixed installations. D.C. switchgear General |
BS EN 61264:1999 | Ceramic pressurized hollow insulators for high-voltage switchgear and controlgear |
IEC 60420:1990 | High-voltage alternating current switch-fuse combinations |
I.S. EN 50508:2009 | MULTI-PURPOSE INSULATING STICKS FOR ELECTRICAL OPERATIONS ON HIGH VOLTAGE INSTALLATIONS |
I.S. EN 50123-7-2:2003 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 7-2: MEASUREMENT, CONTROL AND PROTECTION DEVICES FOR SPECIFIC USE IN D.C. TRACTION SYSTEMS - ISOLATING CURRENT TRANSDUCERS AND OTHER CURRENT MEASURING DEVICES |
IEC 60056:1987 | High-voltage alternating-current circuit-breakers |
IEC 61462:2007 | Composite hollow insulators - Pressurized and unpressurized insulators for use in electrical equipment with rated voltage greater than 1 000 V - Definitions, test methods, acceptance criteria and design recommendations |
IEEE 45-7 : 2012 | RECOMMENDED PRACTICE FOR ELECTRICAL INSTALLATIONS ON SHIPBOARD - AC SWITCHBOARDS |
IEC 61000-4-18:2006+AMD1:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-18: Testing and measurement techniques - Damped oscillatory wave immunity test |
IEC 61958:2000 | High-voltage prefabricated switchgear and controlgear assemblies - Voltage presence indicating systems |
BS 5227:1984 | Specification for a.c. metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 72.5 kV |
VDE 0670-212 : 1995 AMD 1 1998 | ALTERNATING CURRENT EARTHING SWITCHES - INDUCED CURRENT SWITCHING |
BS 5227:1992 | Specification for a.c. metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV |
BS 5311:1996 | High-voltage alternating-current circuit-breakers |
VDE 0414-44-7 : 2000 | INSTRUMENT TRANSFORMERS - PART 7: ELECTRONIC VOLTAGE TRANSFORMERS |
DIN EN 60044-7 : 2000 | INSTRUMENT TRANSFORMERS - PART 7: ELECTRONIC VOLTAGE TRANSFORMERS |
BS 7426(1991) : AMD 8059 | SPECIFICATION FOR HIGH VOLTAGE ALTERNATING CURRENT SWITCH FUSE COMBINATIONS |
NF EN 62271-2 : 2004 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 2: SEISMIC QUALIFICATION FOR RATED VOLTAGES OF 72,5 KV AND ABOVE |
I.S. EN 50123-3:2003 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 3: INDOOR D.C. DISCONNECTORS, SWITCH-DISCONNECTORS AND EARTHING SWITCHES |
98/200517 DC : 0 | |
BS EN 61238-1:2003 | Compression and mechanical connectors for power cables for rated voltages up to 36 kV (<i>U</i><sub>m</sub> = 42 kV) Test methods and requirements |
IEEE C37.04-1999 | IEEE Standard Rating Structure for AC High-Voltage Circuit Breakers |
CEI EN 60044-7 : 2001 | INSTRUMENT TRANSFORMERS - PART 7: ELECTRONIC VOLTAGE TRANSFORMERS |
UNE-EN 60137:2011 | Insulated bushings for alternating voltages above 1 000 V |
BS EN 62271-102 : 2002 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 102: ALTERNATING CURRENT DISCONNECTORS AND EARTHING SWITCHES |
BS EN 50123-7-1:2003 | Railway applications. Fixed installations. d.c. switchgear. Measurement, control and protection devices for specific use in d.c. traction systems Measurement, control and protection devices for specific use in d.c. traction systems. Application guide |
02/201465 DC : DRAFT NOV 2002 | IEC 60092-508 ED. 1 - ELECTRICAL INSTALLATIONS IN SHIPS - PART 508: SWITCHGEAR AND CONTROLGEAR ASSEMBLIES FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 15 KV |
BS IEC 60943:1998 | Guidance concerning the permissible temperature rise for parts of electrical equipment, in particular for terminals |
IEEE 1861-2014 | IEEE Guide for On-Site Acceptance Tests of Electrical Equipment and System Commissioning of 1000 kV AC and Above |
BS EN 62271-2:2003 | High-voltage switchgear and controlgear Seismic qualification for rated voltages of 72,5 kV and above |
BIS IS/IEC 62271-105 : 2002 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 105: ALTERNATING CURRENT SWITCH-FUSE COMBINATIONS |
CEI EN 61360-1 : 2013 | STANDARD DATA ELEMENT TYPES WITH ASSOCIATED CLASSIFICATION SCHEME FOR ELECTRIC ITEMS - PART 1: DEFINITIONS - PRINCIPLES AND METHODS |
CEI EN 50123-1 : 2003 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 1: GENERAL |
99/200375 DC : DRAFT MAR 1999 | IEC 60420 - HIGH-VOLTAGE ALTERNATING CURRENT SWITCH-FUSE COMBINATIONS |
DD IEC/PAS 62001:2004 | Guide to the specification and design evaluation of a.c. filters for HVDC systems |
BIS IS/IEC 62271-200 : 2003 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 200: A.C. METAL-ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UPTO AND INCLUDING 52 KV |
EN 60044-7:2000 | Instrument transformers - Part 7: Electronic voltage transformers |
NF EN 60044-8 : 2006 | INSTRUMENT TRANSFORMERS - PART 8: ELECTRONIC CURRENT TRANSDUCERS |
CSA C60044-2 : 2007 | INSTRUMENT TRANSFORMERS - PART 2: INDUCTIVE VOLTAGE TRANSFORMERS |
IEEE C37.66 : 2005 | REQUIREMENTS FOR CAPACITOR SWITCHES FOR AC SYSTEMS (1 KV TO 38 KV) |
IEC TS 60859:1999 | Cable connections for gas-insulated metal-enclosed switchgear for rated voltages of 72,5 kV and above - Fluid-filled and extruded insulation cables - Fluid-filled and dry type cable-terminations |
CSA C60044-8 :2007 | INSTRUMENT TRANSFORMERS - PART 8: ELECTRONIC CURRENT TRANSFORMERS |
CSA C60044-2 : 2007 : R2011 | INSTRUMENT TRANSFORMERS - PART 2: INDUCTIVE VOLTAGE TRANSFORMERS |
I.S. EN 60265-2:1994 | HIGH-VOLTAGE SWITCHES - HIGH-VOLTAGE SWITCHES FOR RATED VOLTAGES OF 52 KV AND ABOVE |
IEC TR 62271-306:2012 | High-voltage switchgear and controlgear - Part 306: Guide to IEC 62271-100, IEC 62271-1 and other IEC standards related to alternating current circuit-breakers |
BS EN 61000-4-18 : 2007 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-18: TESTING AND MEASUREMENT TECHNIQUES - DAMPED OSCILLATORY WAVE IMMUNITY TEST |
IEC 61238-1:2003 | Compression and mechanical connectors for power cables for rated voltages up to 30 kV (Um = 36 kV) - Part 1: Test methods and requirements |
IEC 61992-4:2006+AMD1:2015 CSV | Railway applications - Fixed installations - DC switchgear - Part 4:Outdoor d.c. disconnectors, switch-disconnectors and earthing switches |
IEC 60204-11:2000 | Safety of machinery - Electrical equipment of machines - Part 11: Requirements for HV equipment for voltages above 1 000 V a.c. or 1 500 V d.c. and not exceeding 36 kV |
IEC 60282-2:2008 | High-voltage fuses - Part 2: Expulsion fuses |
IEC 60044-8:2002 | Instrument transformers - Part 8: Electronic current transformers |
UNE-EN 61869-1:2010 | Instrument transformers -- Part 1: General requirements |
EN 62271-108:2006 | High-voltage switchgear and controlgear - Part 108: High-voltage alternating current disconnecting circuit-breakers for rated voltages of 72,5 kV and above |
EN 60077-4:2003 | Railway applications - Electric equipment for rolling stock - Part 4: Electrotechnical components - Rules for AC circuit-breakers |
IEC GUIDE 111:2004 | Electrical high-voltage equipment in high-voltage substations - Common recommendations for product standards |
CEI EN 60044-8 : 2004 | INSTRUMENT TRANSFORMERS - PART 8: ELECTRONIC CURRENT TRASFORMERS |
I.S. EN 61869-1:2009 | INSTRUMENT TRANSFORMERS - PART 1: GENERAL REQUIREMENTS |
I.S. EN 60204-11:2000 | SAFETY OF MACHINERY - ELECTRICAL EQUIPMENT OF MACHINES PART 11: REQUIREMENTS FOR HV EQUIPMENT FOR VOLTAGES ABOVE 1000 V A.C. OR 1500 V D.C. AND NOT EXCEEDING 36 KV |
13/30281011 DC : 0 | BS EN 61000-6-5 ED.1.0 - ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-5: GENERIC STANDARDS - IMMUNITY FOR POWER STATION AND SUBSTATION ENVIRONMENTS |
BS EN 60044-7:2000 | Instrument transformers Electronic voltage transformers |
BS IEC 60092-503:2007 | Electrical installations in ships Special features. AC supply systems with voltages in the range of above 1 kV up to and including 15 kV |
05/30134423 DC : DRAFT JUN 2005 | IEC 62271-207 - HV SWITCHGEAR ASSEMBLIES - PART 207: SEISMIC QUALIFICATION FOR GAS-INSULATED SWITCHGEAR ASSEMBLIES FOR RATED VOLTAGES ABOVE 52 KV |
BS EN 60376:2005 | Specification of technical grade sulfur hexafluoride (SF6) for use in electrical equipment |
BS EN 50123-2:2003 | Railway applications. Fixed installations. D.C. switchgear D.C. circuit breakers |
94/712993 DC : DRAFT NOV 1994 | PREN 45511 - GUIDE FOR PROCUREMENT - ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR |
97/203920 DC : DRAFT MAR 1997 | IEC 60859-2 - CABLE CONNECTIONS FOR GAS-INSULATED METAL-ENCLOSED SWITCHGEAR FOR RATED VOLTAGES OF 72,5 KV AND ABOVE - PART 2: PREFABRICATED 'DRY TYPE' CABLE TERMINATIONS FOR EXTRUDED INSULATION CABLES |
CSA C60044-7 : 2007 : R2016 | INSTRUMENT TRANSFORMERS - PART 7: ELECTRONIC VOLTAGE TRANSFORMERS |
I.S. EN 62271-209:2007 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 209: CABLE CONNECTIONS FOR GAS-INSULATED METAL-ENCLOSED SWITCHGEAR FOR RATED VOLTAGES ABOVE 52 KV - FLUID-FILLED AND EXTRUDED INSULATION CABLES - FLUID-FILLED AND DRY-TYPE CABLE-TERMINATIONS |
00/201882 DC : DRAFT APR 2000 | BS EN 60298 - A.C. METAL-ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV |
16/30318517 DC : 0 | BS EN 60137 ED. 7.0 - INSULATED BUSHINGS FOR ALTERNATING VOLTAGES ABOVE 1000 V |
CSA C60044-7 : 2007 : R2011 | INSTRUMENT TRANSFORMERS - PART 7: ELECTRONIC VOLTAGE TRANSFORMERS |
99/201444 DC : DRAFT MAR 1999 | IEC 61850-3 - COMMUNICATION NETWORKS AND SYSTEMS IN SUBSTANCES - PART 3: GENERAL REQUIREMENTS |
BS EN 60204-11 : 2001 | SAFETY OF MACHINERY - ELECTRICAL EQUIPMENT OF MACHINES - PART 11: REQUIREMENTS FOR HV EQUIPMENT FOR VOLTAGES ABOVE 1000 V A.C. OR 1500 V D.C. AND NOT EXCEEDING 36 KV |
UNI CEI EN 45510-2-7 : 2011 | GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-7: ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR |
CSA C60044-7 : 2007 | INSTRUMENT TRANSFORMERS - PART 7: ELECTRONIC VOLTAGE TRANSFORMERS |
CSA C60044-1 : 2007 : R2011 | INSTRUMENT TRANSFORMERS - PART 1: CURRENT TRANSFORMERS |
CSA C60044-1 : 2007 | INSTRUMENT TRANSFORMERS - PART 1: CURRENT TRANSFORMERS |
IEC PAS 62271-109:2002 | High-voltage switchgear and controlgear - Part 109: Alternating-current series capacitor by-pass switches |
CEI EN 60480 : 2005 | GUIDELINES FOR THE CHECKING AND TREATMENT OF SULPHUR HEXAFLUORIDE (SF6) TAKEN FROM ELECTRICAL EQUIPMENT AND SPECIFICATION FOR ITS RE-USE |
IEC TR 62063:1999 | High-voltage switchgear and controlgear - The use of electronic and associated technologies in auxiliary equipment of switchgear and controlgear |
I.S. EN 60376:2005 | SPECIFICATION OF TECHNICAL GRADE SULFUR HEXAFLUORIDE (SF[6]) FOR USE IN ELECTRICAL EQUIPMENT |
CSA C61869-1 : 2014 | INSTRUMENT TRANSFORMERS - PART 1: GENERAL REQUIREMENTS |
I.S. EN 50123-2:2003 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - D.C. CIRCUIT BREAKERS |
UNE-EN 50508:2011 | Multi-purpose insulating sticks for electrical operations on high voltage installations |
I.S. EN 50123-7-3:2003 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 7-3: MEASUREMENT, CONTROL AND PROTECTION DEVICES FOR SPECIFIC USE IN D.C. TRACTION SYSTEMS - ISOLATING VOLTAGE TRANSDUCERS AND OTHER VOLTAGE MEASURING DEVICES |
IEC PAS 62001:2004 | Guide to the specification and design evaluation of a.c. filters for HVDC systems |
BS EN 61330:1996 | High-voltage/low-voltage prefabricated substations |
IEC 62271-108:2005 | High-voltage switchgear and controlgear - Part 108: High-voltage alternating current disconnecting circuit-breakers for rated voltages of 72,5 kV and above |
IEC 61243-5:1997 | Live working - Voltage detectors - Part 5: Voltage detecting systems (VDS) |
IEC 62271-209:2007 | High-voltage switchgear and controlgear - Part 209: Cable connections for gas-insulated metal-enclosed switchgear for rated voltages above 52 kV - Fluid-filled and extruded insulation cables - Fluid-filled and dry-type cable-terminations |
IEC 61330:1995 | High-voltage/low voltage prefabricated substations |
IEC 60077-4:2003 | Railway applications - Electric equipment for rolling stock - Part 4: Electrotechnical components - Rules for AC circuit-breakers |
IEC 60480:2004 | Guidelines for the checking and treatment of sulfur hexafluoride (SF<sub>6</sub>) taken from electrical equipment and specification for its re-use |
IEC 62271-2:2003 | High-voltage switchgear and controlgear - Part 2: Seismic qualification for rated voltages of 72,5 kV and above |
IEC 60044-7:1999 | Instrument transformers - Part 7: Electronic voltage transformers |
EN 61462:2007 | Composite hollow insulators - Pressurized and unpressurized insulators for use in electrical equipment with rated voltage greater than 1 000 V - Definitions, test methods, acceptance criteria and design recommendations |
EN 45510-2-7:2002 | Guide for procurement of power station equipment - Part 2-7: Electrical equipment - Switchgear and controlgear |
EN 50123-7-3:2003 | Railway applications - Fixed installations - D.C. switchgear - Part 7-3: Measurement, control and protection devices for specific use in d.c. traction systems - Isolating voltage transducers and other voltage measuring devices |
11/30242675 DC : 0 | BS EN 60099-4 F2 - SURGE ARRESTERS - PART 4: METAL-OXIDE SURGE ARRESTERS WITHOUT GAPS FOR A.C. SYSTEMS |
10/30210015 DC : 0 | BS EN 60099-5 - SURGE ARRESTERS - SELECTION AND APPLICATION RECOMMENDATIONS |
CEI 32-14 : 1998 | HIGH-VOLTAGE FUSES - PART 2: EXPULSION FUSES |
BS EN 60470:2001 | High-voltage alternating current contactors and contactor-based motor starters |
CSA C22.3 No. 61936-1 : 2008 : R2015 | POWER INSTALLATIONS EXCEEDING 1 KV A.C. - PART 1: COMMON RULES |
BS EN 62271-108:2006 | High-voltage switchgear and controlgear High-voltage alternating current disconnecting circuit-breakers for rated voltages of 72,5 kV and above |
01/207232 DC : DRAFT OCT 2001 | |
BS EN 60480:2004 | Guidelines for the checking and treatment of sulphur hexafluoride (SF<sub>6</sub>) taken from electrical equipment and specification for its re-use |
BS EN 61129:1994 | Specification for alternating current earthing switches. Induced current switching |
03/100521 DC : DRAFT MAR 2003 | IEC 62271-107 ED.1.0 - HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 107: ALTERNATING CURRENT FUSED CIRCUIT-SWITCHERS FOR RATED VOLTAGES ABOVE 1 KV UP TO AND INCLUDING 52 KV |
CSA C71.1 : 1999 | INSULATION CO-ORDINATION - PART 1: DEFINITIONS, PRINCIPLES AND RULES |
I.S. EN 61238-1:2003 | COMPRESSION AND MECHANICAL CONNECTORS FOR POWER CABLES FOR RATED VOLTAGES UP TO 36 KV (U[M] = 42 KV) - PART 1: TEST METHODS AND REQUIREMENTS |
03/113996 DC : DRAFT OCT 2003 | IEC 60376 ED.2 - SPECIFICATION OF TECHNICAL GRADE SF6 FOR USE IN ELECTRICAL EQUIPMENT |
04/30112476 DC : DRAFT APR 2004 | |
BS EN 60265-1:1998 | Specification for high-voltage switches Switches for rated voltages above 1 kV and less than 52 kV |
I.S. EN 62271-102:2005 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 102: ALTERNATING CURRENT DISCONNECTORS AND EARTHING SWITCHES (IEC 62271-102:2001 (EQV)) |
CSA C62155 : 2006 : R2011 | HOLLOW PRESSURIZED AND UNPRESSURIZED CERAMIC AND GLASS INSULATORS FOR USE IN ELECTRICAL EQUIPMENT WITH RATED VOLTAGES GREATER THAN 1000 V |
06/30159668 DC : 0 | BS EN 50508 - MULTI-PURPOSE INSULATING STICKS FOR ELECTRICAL OPERATIONS ON HIGH VOLTAGE INSTALLATIONS |
IEC 62155:2003 | Hollow pressurized and unpressurized ceramic and glass insulators for use in electrical equipment with rated voltages greater than 1 000 V |
CEI EN 61869-1 : 2010 | INSTRUMENT TRANSFORMERS - PART 1: GENERAL REQUIREMENTS |
BS EN 50123-7-2:2003 | Railway applications. Fixed installations. d.c. switchgear. Measurement, control and protection devices for specific use in d.c. traction systems Isolating current transducers and other current measuring devices |
CSA C22.3 No. 61936-1 : 2008 | POWER INSTALLATIONS EXCEEDING 1 KV A.C. - PART 1: COMMON RULES |
IEC 60092-503:2007 | Electrical installations in ships - Part 503: Special features - AC supply systems with voltages in the range of above 1 kV up to and including 15 kV |
CEI EN 60137 : 2009 | INSULATED BUSHINGS FOR ALTERNATING VOLTAGES ABOVE 1000 V |
IEC TR 60943:1998+AMD1:2008 CSV | Guidance concerning the permissible temperature rise for parts of electrical equipment, in particular for terminals |
I.S. EN 60077-4:2003 | RAILWAY APPLICATIONS - ELECTRIC EQUIPMENT FOR ROLLING STOCK - PART 4: ELECTROTECHNICAL COMPONENTS - RULES FOR AC CIRCUIT-BREAKERS |
IEC 61869-1:2007 | Instrument transformers - Part 1: General requirements |
IEC 61264:1998 | Ceramic pressurized hollow insulators for high-voltage switchgear and controlgear |
02/714212 DC : DRAFT DEC 2002 | IEC 62271-202 ED.1 - HIGH VOLTAGE/LOW VOLTAGE PREFABRICATED SUBSTATIONS |
NF EN 62271-108 : 2006 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 108: HIGH-VOLTAGE ALTERNATING CURRENT DISCONNECTING CIRCUIT-BREAKERS FOR RATED VOLTAGES OF 72,5 KV AND ABOVE |
EN 60470:2000/corrigendum Jun. 2000 | HIGH-VOLTAGE ALTERNATING CURRENT CONTACTORS AND CONTACTOR-BASED MOTOR STARTERS |
EN 50508:2009 | Multi-purpose insulating sticks for electrical operations on high voltage installations |
EN 62271-2:2003 | High-voltage switchgear and controlgear - Part 2: Seismic qualification for rated voltages of 72,5 kV and above |
EN 61958:2001 | High-voltage prefabricated switchgear and controlgear assemblies - Voltage presence indicating systems |
EN 50123-7-1:2003 | Railway applications - Fixed installations - D.C. switchgear - Part 7-1: Measurement, control and protection devices for specific use in d.c. traction systems - Application guide |
EN 50123-1:2003 | Railway applications - Fixed installations - D.C. switchgear - Part 1: General |
EN 61330:1996 | High-voltage/low-voltage prefabricated substations |
EN 50123-4:2003/A1:2013 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 4: OUTDOOR D.C. DISCONNECTORS, SWITCH-DISCONNECTORS AND EARTHING SWITCHES |
EN 61869-1:2009 | Instrument transformers - Part 1: General requirements |
EN 50123-2:2003 | Railway applications - Fixed installations - D.C. switchgear - Part 2: D.C. circuit breakers |
EN 61264:1998/corrigendum:2000 | CERAMIC PRESSURIZED HOLLOW INSULATORS FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR |
EN 60044-8:2002 | Instrument transformers - Part 8: Electronic current transformers |
EN 61129:1994/A1:1995 | ALTERNATING CURRENT EARTHING SWITCHES - INDUCED CURRENT SWITCHING |
EN 61238-1:2003 | Compression and mechanical connectors for power cables for rated voltages up to 36 kV (Um = 42 kV) - Part 1: Test methods and requirements |
EN 60265-1:1998 | High-voltage switches - Part 1: Switches for rated voltages above 1 kV and less than 52 kV |
EN 60480:2004 | Guidelines for the checking and treatment of sulphur hexafluoride (SF6) taken from electrical equipment and specification for its re-use |
EN 50123-3:2003/A1:2013 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 3: INDOOR D.C. DISCONNECTORS, SWITCH-DISCONNECTORS AND EARTHING SWITCHES |
CAN/CSA-IEC 61000-4-18:14 (R2018) | Electromagnetic compatibility (EMC) - Part 4-18: Testing and measurement techniques - Damped oscillatory wave immunity test (Adopted IEC 61000-4-18:2011, edition 1:2006 consolidated with amendment 1:2010) | Compatibilité électromagnétique (CEM) - Partie 4-18 : Techniques d\'essai et de mesure - Essai d\'immunité à l\'onde oscillatoire amortie (norme CEI 61000-4-18:2011 adoptée, édition 1:2006 consolidée par l\'amendement 1:2010) |
IEC 60480:2004 | Guidelines for the checking and treatment of sulfur hexafluoride (SF<sub>6</sub>) taken from electrical equipment and specification for its re-use |
IEC 60050-351:2013 | International Electrotechnical Vocabulary (IEV) - Part 351: Control technology |
IEC 60038:2009 | IEC standard voltages |
IEC 60270:2000+AMD1:2015 CSV | High-voltage test techniques - Partial discharge measurements |
IEC 60130-7:1971 | Connectors for frequencies below 3 MHz - Part 7: Circular multipole connectors with bayonet or push-pull coupling |
IEC 60050-131:2002 | International Electrotechnical Vocabulary (IEV) - Part 131: Circuit theory |
IEC 60245-2:1994+AMD1:1997+AMD2:1997 CSV | Rubber insulated cables - Rated voltages up to and including 450/750 V - Part 2: Test methods |
IEC 60245-1:2003+AMD1:2007 CSV | Rubber insulated cables - Rated voltages up to and including 450/750 V - Part 1: General requirements |
IEC 60130-3:1965 | Connectors for frequencies below 3 MHz - Part 3: Battery connectors |
IEC 60227-6:2001 | Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 6: Lift cables and cables for flexible connections |
IEC 60227-4:1992+AMD1:1997 CSV | Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 4: Sheathed cables for fixed wiring |
IEC 60947-7-2:2009 | Low-voltage switchgear and controlgear - Part 7-2: Ancillary equipment - Protective conductor terminal blocks for copper conductors |
IEC 60130-4:1966 | Connectors for frequencies below 3 MHz - Part 4: Circular multipole connectors with threaded coupling |
IEC 60228:2004 | Conductors of insulated cables |
IEC 60130-0:1970 | Connectors for frequencies below 3 MHz. Part 0: Guide to drawing information in detail specifications |
IEC 60227-7:1995+AMD1:2003+AMD2:2011 CSV | Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 7: Flexible cables screened and unscreened with two or more conductors |
IEC 61020-4:1991 | Electromechanical switches for use in electronic equipement - Part 4: Sectional specification for lever (toggle) switches |
IEC 60130-6:1965 | Connectors for frequencies below 3 MHz - Part 6: Rectangular miniature multipole connectors with blade contacts |
IEC 61810-5:1998 | Electromechanical non-specified time all-or-nothing relays - Part 5: Insulation coordination |
IEC 60245-6:1994 | Rubber insulated cables - Rated voltages up to and including 450/750 V - Part 6: Arc welding electrode cables |
IEC 60417-1:2002 | Graphical symbols for use on equipment - Part 1: Overview and application |
IEC 61000-4-1:2006 | Electromagnetic compatibility (EMC) - Part 4-1: Testing and measurement techniques - Overview of IEC 61000-4 series |
IEC 60050-811:1991 | International Electrotechnical Vocabulary (IEV) - Part 811: Electric traction |
IEC 60947-4-1:2009+AMD1:2012 CSV | Low-voltage switchgear and controlgear - Part 4-1: Contactors and motor-starters - Electromechanical contactors and motor-starters |
IEC 60130-12:1976 | Connectors for frequencies below 3 MHz - Part 12: Link and test connectors |
IEC 60073:2002 | Basic and safety principles for man-machine interface, marking and identification - Coding principles for indicators and actuators |
IEC 60068-2-63:1991 | Environmental testing - Part 2: Test methods - Test Eg: Impact, spring hammer. |
IEC 60730-2-13:2017 | Automatic electrical controls - Part 2-13: Particular requirements for humidity sensing controls |
IEC 60245-5:1994 | Rubber insulated cables - Rated voltages up to and including 450/750 V - Part 5: Lift cables |
IEC 60050-151:2001 | International Electrotechnical Vocabulary (IEV) - Part 151: Electrical and magnetic devices |
IEC 60502-1:2004+AMD1:2009 CSV | Power cables with extruded insulation and their accessories for rated voltages from 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) up to 30 kV(<em>U</em><sub>m</sub> = 36 kV) - Part 1: Cables for rated voltages of 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) and 3 kV (<em>U</em><sub>m</sub> = 3,6 kV) |
IEC 60050-441:1984 | International Electrotechnical Vocabulary (IEV) - Part 441: Switchgear, controlgear and fuses |
IEC 61000-5-5:1996 | Electromagnetic compatibility (EMC) - Part 5: Installation and mitigation guidelines - Section 5: Specification of protective devices for HEMP conducted disturbance. Basic EMC Publication |
IEC 60227-3:1993+AMD1:1997 CSV | Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 3: Non-sheathed cables for fixed wiring |
IEC 60269-2:2013+AMD1:2016 CSV | Low-voltage fuses - Part 2: Supplementary requirements for fuses for use by authorized persons (fuses mainly for industrial application) - Examples of standardized systems of fuses A to K |
IEC 60130-15:1975 | Connectors for frequencies below 3 MHz. Part 15: Ultra-miniature board-mounted printed- wiring connectors having a staggered contact spacing of 1.27 mm (0.05 in) |
IEC 60051-4:1984 | Direct acting indicating analogue electrical measuring instruments and their accessories. Part 4: Special requirements for frequency meters |
IEC 60130-9:2011 | Connectors for frequencies below 3 MHz - Part 9: Circular connectors for radio and associated sound equipment |
IEC 60130-5:1966 | Connectors for frequencies below 3 MHz - Part 5: Rectangular multipole connectors with blade contacts |
IEC 60485:1974 | Digital electronic d.c. voltmeters and d.c. electronic analogue-to-digital converters |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
IEC 60227-2:1997+AMD1:2003 CSV | Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 2: Test methods |
IEC 61810-1:2015 | Electromechanical elementary relays - Part 1: General and safety requirements |
IEC 60269-1:2006+AMD1:2009+AMD2:2014 CSV | Low-voltage fuses - Part 1: General requirements |
IEC 60056:1987 | High-voltage alternating-current circuit-breakers |
IEC 60376:2005 | Specification of technical grade sulfur hexafluoride (SF<sub>6</sub>) for use in electrical equipment |
IEC 60947-7-1:2009 | Low-voltage switchgear and controlgear - Part 7-1: Ancillary equipment - Terminal blocks for copper conductors |
IEC 60269-2-1:2004 | Low-voltage fuses - Part 2-1: Supplementary requirements for fuses for use by authorized persons (fuses mainly for industrial application) - Sections I to VI: Examples of types of standardized fuses |
IEC 60130-10:1971 | Connectors for frequencies below 3 MHz - Part 10: Connectors for coupling an external low-voltage power supply to portable entertainment equipment |
IEC 60130-8:1976 | Connectors for frequencies below 3 MHz. Part 8: Concentric connectors for audio circuits in radio receivers |
IEC 61166:1993 | High-voltage alternating current circuit-breakers - Guide for seismic qualification of high-voltage alternating current circuit-breakers |
IEC 61810-7:2006 | Electromechanical elementary relays - Part 7: Test and measurement procedures |
IEC 60227-1:2007 | Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 1: General requirements |
IEC 60085:2007 | Electrical insulation - Thermal evaluation and designation |
IEC 60051-2:1984 | Direct acting indicating analogue electrical measuring instruments and their accessories. Part 2: Special requirements for ammeters and voltmeters |
IEC 60064:1993+AMD1:2000+AMD2:2002+AMD3:2005 CSV | Tungsten filament lamps for domestic and similar general lighting purposes - Performance requirements |
IEC 60130-11A:1975 | Connectors for frequencies below 3 MHz - Part 11 - First supplement: Multi-row board mounted printed circuit connectors having contact and termination spacing on a 2.54 mm (0.1 in) square grid |
IEC 60296:2012 RLV | Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear |
IEC 60130-4A:1970 | Connectors for frequencies below 3 MHz - Part 4: Circular multipole connectors with threaded coupling - First supplement |
IEC 60130-11:1971 | Connectors for frequencies below 3 MHz. Part 11: Edge socket connectors with closed ends and having a contact spacing of 2.54 mm (0.1 in) mating either with board mounted connectors or printed wiring boards with edge board contacts |
IEC 60245-8:1998+AMD1:2003+AMD2:2011 CSV | Rubber insulated cables - Rated voltages up to and including 450/750 V - Part 8: Cords for applications requiring high flexibility |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60051-5:1985 | Direct acting indicating analogue electrical measuring instruments and their accessories. Part 5: Special requirements for phase meters, power factor meters and synchroscopes |
IEC 60050-446:1983 | International Electrotechnical Vocabulary (IEV) - Part 446: Electrical relays |
IEC 60068-2-17:1994 | Basic environmental testing procedures - Part 2-17: Tests - Test Q: Sealing |
IEC 60245-4:2011 | Rubber insulated cables - Rated voltages up to and including 450/750 V - Part 4: Cords and flexible cables |
IEC 60417-2:1998 | Graphical symbols for use on equipment - Part 2: Symbol originals |
IEC 60947-4-2:2011 | Low-voltage switchgear and controlgear - Part 4-2: Contactors and motor-starters - AC semiconductor motor controllers and starters |
IEC 60393-1:2008 | Potentiometers for use in electronic equipment - Part 1: Generic specification |
IEC 60255-5:2000 | Electrical Relays - Part 5: Insulation coordination for measuring relays and protection equipment - Requirements and tests |
IEC 60130-13:1971 | Connectors for frequencies below 3 MHz - Part 13: Edge socket connectors with open ends, off-centre guide, having a contact spacing of 2,54 mm (0,1 in) |
IEC 60669-1:2017 | Switches for household and similar fixed-electrical installations - Part 1: General requirements |
IEC 60034-1:2017 | Rotating electrical machines - Part 1: Rating and performance |
IEC 60255-8:1990 | Electrical relays - Part 8: Thermal electrical relays |
IEC 60071-2:1996 | Insulation co-ordination - Part 2: Application guide |
IEC 60050-826:2004 | International Electrotechnical Vocabulary (IEV) - Part 826: Electrical installations |
CISPR 11:2015 RLV | Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement |
IEC 60947-3:2008+AMD1:2012+AMD2:2015 CSV | Low-voltage switchgear and controlgear - Part 3: Switches, disconnectors, switch-disconnectors and fuse-combination units |
IEC 60255-23:1994 | Electrical relays - Part 23: Contact performance |
IEC 60130-16:1976 | Connectors for frequencies below 3 MHz - Part 16: Printed circuit board mounted connectors with two rows of staggered contacts and terminations with spacing of 2,54 mm (0,1 in) |
IEC 60059:1999+AMD1:2009 CSV | IEC standard current ratings |
IEC 61180-1:1992 | High-voltage test techniques for low voltage equipment - Part 1: Definitions, test and procedure requirements |
IEC 60947-2:2016 | Low-voltage switchgear and controlgear - Part 2: Circuit-breakers |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 60507:2013 | Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems |
IEC 60071-1:2006+AMD1:2010 CSV | Insulation co-ordination - Part 1: Definitions, principles and rules |
IEC 61000-4-29:2000 | Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests |
IEC 60309-1:1999+AMD1:2005+AMD2:2012 CSV | Plugs, socket-outlets and couplers for industrial purposes - Part 1: General requirements |
IEC 60445:2017 | Basic and safety principles for man-machine interface, marking and identification - Identification of equipment terminals, conductor terminations and conductors |
IEC 60050-581:2008 | International Electrotechnical Vocabulary (IEV) - Part 581: Electromechanical components for electronic equipment |
IEC 61000-5-7:2001 | Electromagnetic compatibility (EMC) - Part 5-7: Installation and mitigation guidelines - Degrees of protection provided by enclosures against electromagnetic disturbances (EM code) |
CISPR 16-1:1999+AMD1:2002 CSV | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1: Radio disturbance and immunity measuring apparatus |
IEC 60309-2:1999+AMD1:2005+AMD2:2012 CSV | Plugs, socket-outlets and couplers for industrial purposes - Part 2: Dimensional interchangeability requirements for pin and contact-tube accessories |
IEC 60227-5:2011 | Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 5: Flexible cables (cords) |
IEC TR 61000-5-1:1996 | Electromagnetic compatibility (EMC) - Part 5: Installation and mitigation guidelines - Section 1: General considerations - Basic EMC publication |
IEC 60130-17:1998 | Connectors for frequencies below 3 MHz - Part 17: Detailspecification for interconnection devices which permit multi-directional mating, for use with rechargeable batteries |
IEC 60130-14:1975 | Connectors for frequencies below 3 MHz - Part 14: Multi-row board mounted printed board connectors having contact and termination spacing on a 2,54 mm (0,1 in) square grid |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.