• Shopping Cart
    There are no items in your cart

IEC 60068-2-31:2008

Current

Current

The latest, up-to-date edition.

Environmental testing - Part 2-31: Tests - Test Ec: Rough handling shocks, primarily for equipment-type specimens

Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English - French, Spanish, Castilian

Published date

21-05-2008

€83.17
Excluding VAT

FOREWORD
1 Scope
2 Normative references
3 General description of test
4 Initial measurements
5 Testing
  5.1 Drop and topple
      5.1.1 Description
      5.1.2 Test Facility
      5.1.3 Testing procedures
  5.2 Free fall - Procedure 1
      5.2.1 Description
      5.2.2 Test Facility
      5.2.3 Test severity
      5.2.4 Testing procedures
  5.3 Free fall repeated - Procedure 2
      5.3.1 Description
      5.3.2 Test facility
      5.3.3 Test severity
      5.3.4 Testing procedure
6 Final measurements
7 Information to be included in the relevant specification
  7.1 Drop and topple test
  7.2 Free fall and free fall repeated tests
8 Information to be given in the test report
Annex A (normative) Test apparatus for repeated
        free fall test - Procedure 2
Annex B (informative) Selection of test severities
        for free fall tests - Guidance

IEC 60068-2-31:2008 deals with a test procedure for simulating the effects of rough handling shocks, primarily in equipment-type specimens, the effects of knocks, jolts and falls which may be received during repair work or rough handling in operational use. This procedure does not simulate the effects of impacts received during transportation as loosely constrained cargo. Where the effects of loose cargo transportation are to be assessed, test Ee: Bounce should be used. Also this procedure does not simulate the effects of shock applied to installed equipments. Where this effect is to be assessed refer to test Ea: Shock. Testing should only be specified for equipment likely to receive such rough handling, for example those of small to medium size and mass, and should only be applied to those faces and corners where there is a risk of such treatment being encountered. In general, equipment which is frequently handled and serviced (for example field equipment and unit spares) can be considered at risk, whereas equipment forming an integral part of a permanent installation would not normally be considered at risk and need not be tested. Testing may not be applicable to fragile unprotected equipment of irregular shape (for example aircraft nose radar) which, when removed from the installation would be contained in a handling frame or jig. It may however be applicable to these items of equipment when they are in their transit case or in their handling frame or jig. For equipment which stands only on one face (for example the normal base) the test is generally only applied to that face. Shock tests are performed on the specimen when fixed to the test machine. Drop and topple, free fall, repeated free fall and bounce tests are performed with the specimen free. This second edition cancels and replaces the first edition, published in 1969 and constitutes a technical revision. The major changes with regard to the previous edition concern the introduction of soft packaging tests, where appropriate. This new edition of IEC 60068-2-31 now incorporates the second edition of IEC 60068-2-32 (1975).

Committee
TC 104
DevelopmentNote
Supersedes IEC 60068-2-32. (05/2008) Stability Date: 2020. (10/2012)
DocumentType
Standard
Pages
32
PublisherName
International Electrotechnical Committee
Status
Current
Supersedes

I.S. EN IEC 62828-1:2018 REFERENCE CONDITIONS AND PROCEDURES FOR TESTING INDUSTRIAL AND PROCESS MEASUREMENT TRANSMITTERS - PART 1: GENERAL PROCEDURES FOR ALL TYPES OF TRANSMITTERS
CEI EN 60601-1-11 : 2016 MEDICAL ELECTRICAL EQUIPMENT - PART 1-11: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - COLLATERAL STANDARD: REQUIREMENTS FOR MEDICAL ELECTRICAL EQUIPMENT AND MEDICAL ELECTRICAL SYSTEMS USED IN THE HOME HEALTHCARE ENVIRONMENT
12/30240603 DC : 0 BS EN 60320-1 ED 3.0 - APPLIANCE COUPLERS FOR HOUSEHOLD AND SIMILAR GENERAL PURPOSES - PART 1: GENERAL REQUIREMENTS
13/30287730 DC : 0 BS EN 62828 ED 1.0 - REFERENCE CONDITIONS AND PROCEDURES FOR INDUSTRIAL MEASUREMENT TRANSMITTERS - PART 1: GENERAL PROCEDURES FOR ALL TYPES OF TRANSMITTERS
BS ISO 17966:2016 Assistive products for personal hygiene that support users. Requirements and test methods
04/30031093 DC : DRAFT FEB 2004 ISO 4064-3 - MEASUREMENT OF WATER FLOW IN CLOSED FULLY CHARGED CONDUITS - METERS FOR COLD POTABLE WATER AND HOT WATER - PART 3: TEST METHODS AND EQUIPMENT
ISO 14708-7:2013 Implants for surgery Active implantable medical devices Part 7: Particular requirements for cochlear implant systems
BS EN 60862-1:2015 Surface acoustic wave (SAW) filters of assessed quality Generic specification
BS EN 61514-2:2013 Industrial process control systems Methods of evaluating the performance of intelligent valve positioners with pneumatic outputs mounted on an actuator valve assembly
CEI EN 60068-2-47 : 2006 ENVIRONMENTAL TESTING - PART 2-47: TESTS - MOUNTING OF SPECIMENS FOR VIBRATION, IMPACT AND SIMILAR DYNAMIC TESTS
CEI EN 60728-3 : 2011 CABLE NETWORKS FOR TELEVISION SIGNALS, SOUND SIGNALS AND INTERACTIVE SERVICES - PART 3: ACTIVE WIDEBAND EQUIPMENT FOR CABLE NETWORKS
PD IEC/TR 60721-4-2:2002 Classification of environmental conditions. Guidance for the correlation and transformation of environmental condition classes of IEC 60721-3 to the environmental tests of IEC 60068 Transportation
UNI EN ISO 80601-2-61 : 2011 MEDICAL ELECTRICAL EQUIPMENT - PART 2-61: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF PULSE OXIMETER EQUIPMENT
BS EN ISO 80601-2-61:2011 Medical electrical equipment Particular requirements for basic safety and essential performance of pulse oximeter equipment
12/30258455 DC : 0 FPREN 60065:2011+FPRAA - AUDIO, VIDEO AND SIMILAR ELECTRONIC APPARATUS - SAFETY REQUIREMENTS
ANSI/AAMI CI86:2017 COCHLEAR IMPLANT SYSTEMS: REQUIREMENTS FOR SAFETY, FUNCTIONAL VERIFICATION, LABELING AND RELIABILITY REPORTING
BS EN 61514:2002 Industrial-process control systems. Methods of evaluating the performance of valve positioners with pneumatic outputs
PREN ISO 80601-2-61 : DRAFT 2009 MEDICAL ELECTRICAL EQUIPMENT - PART 2-61: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF PULSE OXIMETER EQUIPMENT FOR MEDICAL USE
BS EN 60728-5:2008 Cable networks for television signals, sound signals and interactive services Headend equipment
PD IEC/TR 61916:2017 Electrical accessories. Harmonization of general rules
BS EN 62575-1:2016 Radio frequency (RF) bulk acoustic wave (BAW) filters of assessed quality Generic specification
BS ISO 11614:1999 Reciprocating internal combustion compression-ignition engines. Apparatus for measurement of the opacity and for determination of the light absorption coefficient of exhaust gas
BS ISO 17363:2013 Supply chain applications of RFID. Freight containers
I.S. EN 62604-1:2015 SURFACE ACOUSTIC WAVE (SAW) AND BULK ACOUSTIC WAVE (BAW) DUPLEXERS OF ASSESSED QUALITY - PART 1: GENERIC SPECIFICATION
15/30325282 DC : 0 BS EN 62884-1 - MEASUREMENT TECHNIQUES OF PIEZOELECTRIC, DIELETIRIC AND ELECTROSTATIC OSCILLATORS - PART 1: BASIC METHODS FOR THE MEASUREMENT
10/30181171 DC : 0 BS EN 62586 - POWER QUALITY MONITORING DEVICES IN POWER SUPPLY SYSTEMS
CEI EN 60086-5 : 2012 PRIMARY BATTERIES - PART 5: SAFETY OF BATTERIES WITH AQUEOUS ELECTROLYTE
CEI EN 62488-2 : 1ED 2018 POWER LINE COMMUNICATION SYSTEMS FOR POWER UTILITY APPLICATIONS - PART 2: ANALOGUE POWER LINE CARRIER TERMINALS OR APLC
98/230491 DC : DRAFT MARCH 1998 IEC 60728-5 - CABLED DISTRIBUTION SYSTEMS FOR TELEVISION AND SOUND SIGNALS - PART 5: HEAD END EQUIPMENT
BS EN 60601-1-12:2015 Medical electrical equipment General requirements for basic safety and essential performance. Collateral Standard: Requirements for medical electrical equipment and medical electrical systems intended for use in the emergency medical services environment
BS EN 60539-1:2016 Directly heated negative temperature coefficient thermistors Generic specification
BS EN 62884-1:2017 Measurement techniques of piezoelectric, dielectric and electrostatic oscillators Basic methods for the measurement
BS EN 60068-2-47:2005 Environmental testing Tests. Mounting of specimens for vibration, impact and similar dynamic tests
I.S. HD 60269-3:2010 LOW-VOLTAGE FUSES - PART 3: SUPPLEMENTARY REQUIREMENTS FOR FUSES FOR USE BY UNSKILLED PERSONS (FUSES MAINLY FOR HOUSEHOLD AND SIMILAR APPLICATIONS) - EXAMPLES OF STANDARDIZED SYSTEMS OF FUSES A TO F (IEC 60269-3:2010 (MOD))
10/30218875 DC : 0 BS EN 50130-5:2010 - ALARM SYSTEMS - PART 5: ENVIRONMENTAL TEST METHODS
BS EN 62387:2016 Radiation protection instrumentation. Passive integrating dosimetry systems for individual, workplace and environmental monitoring of photon and beta radiation
BS ISO 15817:2012 Earth-moving machinery. Safety requirements for remote operator control systems
PREN 12405-3 : DRAFT 2013 GAS METERS - CONVERSION DEVICES - PART 3: FLOW COMPUTER
CEI EN 61291-5-2 : 2005 OPTICAL AMPLIFIERS - PART 5-2: QUALIFICATION SPECIFICATIONS - RELIABILITY QUALIFICATION FOR OPTICAL FIBRE AMPLIFIERS
OIML R 143 : 2009 INSTRUMENTS FOR THE CONTINUOUS MEASUREMENT OF SO[2] IN STATIONARY SOURCE EMISSIONS
UNE-EN 12405-1:2006 Gas meters - Conversion devices - Part 1: Volume conversion
NF EN 80601-2-30 : 2011 AMD 1 2015 MEDICAL ELECTRICAL EQUIPMENT - PART 2-30: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF AUTOMATED NON-INVASIVE SPHYGMOMANOMETERS
OIML R 137-1 & 2 : 2012 AMD 2014 GAS METERS - PART 1: METROLOGICAL AND TECHNICAL REQUIREMENTS; PART 2: METROLOGICAL CONTROLS AND PERFORMANCE TESTS
UNE-EN 50467:2012 Railway applications - Rolling stock - Electrical connectors, requirements and test methods
I.S. EN 60689:2009 MEASUREMENT AND TEST METHODS FOR TUNING FORK QUARTZ CRYSTAL UNITS IN THE RANGE FROM 10 KHZ TO 200 KHZ AND STANDARD VALUES
CEI EN 60689 : 2009 MEASUREMENT AND TEST METHODS FOR TUNING FORK QUARTZ CRYSTAL UNITS IN THE RANGE FROM 10 KHZ TO 200 KHZ AND STANDARD VALUES
I.S. EN 62745:2017 SAFETY OF MACHINERY - REQUIREMENTS FOR CABLELESS CONTROL SYSTEMS OF MACHINERY
I.S. EN 61010-2-201:2013 SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL AND LABORATORY USE - PART 2-201: PARTICULAR REQUIREMENTS FOR CONTROL EQUIPMENT (IEC 61010-2-201:2013 (EQV))
I.S. EN 62586-1:2017 POWER QUALITY MEASUREMENT IN POWER SUPPLY SYSTEMS - PART 1: POWER QUALITY INSTRUMENTS (PQI)
BS EN ISO 80601-2-12:2011 Medical electrical equipment Particular requirements for basic safety and essential performance of critical care ventilators
I.S. EN 50467:2011 RAILWAY APPLICATIONS - ROLLING STOCK - ELECTRICAL CONNECTORS, REQUIREMENTS AND TEST METHODS
I.S. EN 61481-1:2014 LIVE WORKING - PHASE COMPARATORS - PART 1: CAPACITIVE TYPE TO BE USED FOR VOLTAGES EXCEEDING 1 KV A.C.
I.S. EN 60770-3:2014 TRANSMITTERS FOR USE IN INDUSTRIAL-PROCESS CONTROL SYSTEMS - PART 3: METHODS FOR PERFORMANCE EVALUATION OF INTELLIGENT TRANSMITTERS
OIML D 11 : 2013 GENERAL REQUIREMENTS FOR MEASURING INSTRUMENTS - ENVIRONMENTAL CONDITIONS
I.S. EN 62575-1:2016 RADIO FREQUENCY (RF) BULK ACOUSTIC WAVE (BAW) FILTERS OF ASSESSED QUALITY - PART 1: GENERIC SPECIFICATION
OIML R 35-1 : 2007 AMD 2014 MATERIAL MEASURES OF LENGTH FOR GENERAL USE - PART 1: METROLOGICAL AND TECHNICAL REQUIREMENTS
UNE-EN 62752:2017 In-cable control and protection device for mode 2 charging of electric road vehicles (IC-CPD)
I.S. EN 60539-1:2016 DIRECTLY HEATED NEGATIVE TEMPERATURE COEFFICIENT THERMISTORS - PART 1: GENERIC SPECIFICATION
CSA C22.2 No. 60335-2-56 : 2015 HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - SAFETY - PART 2-56: PARTICULAR REQUIREMENTS FOR PROJECTORS AND SIMILAR APPLIANCES
I.S. EN 62488-2:2017 POWER LINE COMMUNICATION SYSTEMS FOR POWER UTILITY APPLICATIONS - PART 2: ANALOGUE POWER LINE CARRIER TERMINALS OR APLC
BS EN 60086-4:2015 Primary batteries Safety of lithium batteries
NF EN 45502-2-3 : 2010 ACTIVE IMPLANTABLE MEDICAL DEVICES - PART 2-3: PARTICULAR REQUIREMENTS FOR COCHLEAR AND AUDITORY BRAINSTEM IMPLANT SYSTEMS
UNE-EN 60728-3:2012 Cable networks for television signals, sound signals and interactive services - Part 3: Active wideband equipment for cable networks
NF EN 62040-3 : 2012 UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 3: METHOD OF SPECIFYING THE PERFORMANCE AND TEST REQUIREMENTS
I.S. EN 60546-1:2010 CONTROLLERS WITH ANALOGUE SIGNALS FOR USE IN INDUSTRIAL-PROCESS CONTROL SYSTEMS - PART 1: METHODS OF EVALUATING THE PERFORMANCE
EN 60335-1:2012/A13:2017 HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - SAFETY - PART 1: GENERAL REQUIREMENTS (IEC 60335-1:2010, MODIFIED)
EN 61535:2009/A1:2013 INSTALLATION COUPLERS INTENDED FOR PERMANENT CONNECTION IN FIXED INSTALLATIONS (IEC 61535:2009/A1:2012)
IEC 60086-5:2016 RLV Primary batteries - Part 5: Safety of batteries with aqueous electrolyte
BS EN 13718-1:2014 Medical vehicles and their equipment. Air ambulances Requirements for medical devices used in air ambulances
BS EN 61535 : 2009 INSTALLATION COUPLERS INTENDED FOR PERMANENT CONNECTION IN FIXED INSTALLATIONS
BS EN 61010-2-201:2013 Safety requirements for electrical equipment for measurement, control and laboratory use Particular requirements for control equipment
IEC 62752:2016 In-cable control and protection device for mode 2 charging of electric road vehicles (IC-CPD)
IEC 60086-5:2016 Primary batteries - Part 5: Safety of batteries with aqueous electrolyte
IEC 60873:1986 Methods of evaluating the performance of electrical and pneumatic analogue chart recorders for use in industrial-process control systems
BS EN ISO 14630:2012 Non-active surgical implants. General requirements
EN 60770-1:2011 Transmitters for use in industrial-process control systems - Part 1: Methods for performance evaluation
EN 60601-2-52:2010/A1:2015 MEDICAL ELECTRICAL EQUIPMENT - PART 2-52: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF MEDICAL BEDS
DIN EN 14154-2:2011-06 WATER METERS - PART 2: INSTALLATION AND CONDITIONS OF USE
EN 61243-3:2014/AC:2015 LIVE WORKING - VOLTAGE DETECTORS - PART 3: TWO-POLE LOW-VOLTAGE TYPE
EN 60728-14:2014 Cable networks for television signals, sound signals and interactive services - Part 14: Optical transmission systems using RFoG technology
EN 50130-5:2011 ALARM SYSTEMS - PART 5: ENVIRONMENTAL TEST METHODS
EN 60689:2009 Measurement and test methods for tuning fork quartz crystal units in the range from 10 kHz to 200 kHz and standard values
EN 12405 : 2002 GAS METERS - GAS-VOLUME ELECTRONIC CONVERSION DEVICES
EN 60086-5:2016 Primary batteries - Part 5: Safety of batteries with aqueous electrolyte
EN 62040-5-3:2017 Uninterruptible power systems (UPS) - Part 5-3: DC output UPS - Performance and test requirements
DIN EN ISO 4064-2:2017-10 WATER METERS FOR COLD POTABLE WATER AND HOT WATER - PART 2: TEST METHODS (ISO 4064-2:2014)
EN 62387-1:2012 Radiation protection instrumentation - Passive integrating dosimetry systems for environmental and personal monitoring - Part 1: General characteristics and performance requirements
EN 62137-1-3:2009 Surface mounting technology - Environmental and endurance test methods for surface mount solder joint - Part 1-3: Cyclic drop test
EN 62586-1:2017 Power quality measurement in power supply systems - Part 1: Power quality instruments (PQI)
EN 61131-2:2007 Programmable controllers - Part 2: Equipment requirements and tests
EN 62604-1:2015 Surface acoustic wave (SAW) and bulk acoustic wave (BAW) duplexers of assessed quality - Part 1: Generic specification
EN 60068-2-47:2005 Environmental testing - Part 2-47: Tests - Mounting of specimens for vibration, impact and similar dynamic tests
EN 62387:2016 RADIATION PROTECTION INSTRUMENTATION - PASSIVE INTEGRATING DOSIMETRY SYSTEMS FOR INDIVIDUAL, WORKPLACE AND ENVIRONMENTAL MONITORING OF PHOTON AND BETA RADIATION (IEC 62387:2012, MODIFIED)
EN 61514-2:2013 INDUSTRIAL PROCESS CONTROL SYSTEMS - PART 2: METHODS OF EVALUATING THE PERFORMANCE OF INTELLIGENT VALVE POSITIONERS WITH PNEUMATIC OUTPUTS MOUNTED ON AN ACTUATOR VALVE ASSEMBLY (IEC 61514-2:2013)
EN 61481-1:2014 Live working - Phase comparators - Part 1: Capacitive type to be used for voltages exceeding 1 kV a.c.
EN 61298-3:2008 Process measurement and control devices - General methods and procedures for evaluating performance - Part 3: Tests for the effects of influence quantities
EN 61291-5-2:2017 Optical amplifiers - Part 5-2: Qualification specifications - Reliability qualification for optical fibre amplifiers
IPC 9592 : B REQUIREMENTS FOR POWER CONVERSION DEVICES FOR THE COMPUTER AND TELECOMMUNICATIONS INDUSTRIES
NF EN ISO 80601-2-61 : 2011 MEDICAL ELECTRICAL EQUIPMENT - PART 2-61: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF PULSE OXIMETER EQUIPMENT
12/30255394 DC : DRAFT APR 2012 BS EN 62586-1 - POWER QUALITY MEASUREMENT IN POWER SUPPLY SYSTEMS - POWER QUALITY INSTRUMENTS (PQI)
BS EN 60601-1-11:2015 Medical electrical equipment General requirements for basic safety and essential performance. Collateral Standard: Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment
11/30245877 DC : 0 BS EN 62387 - RADIATION PROTECTION INSTRUMENTATION - PASSIVE INTEGRATING DOSIMETRY SYSTEMS FOR PERSONAL AND ENVIRONMENTAL MONITORING
12/30266709 DC : 0 BS EN ISO 4064-2 - WATER METERS FOR COLD POTABLE WATER AND HOT WATER - PART 2: TEST METHODS
99/240909 DC : DRAFT MAR 1999 BS EN 50315-1 - ACCUMULATORS FOR USE IN PHOTOVOLTAIC SYSTEMS - PART 1: SAFETY - TEST REQUIREMENTS AND PROCEDURE
UNE-EN ISO 16061:2015 Instrumentation for use in association with non-active surgical implants - General requirements (ISO 16061:2015)
BS EN 60873:1993 Methods of evaluating the performance of electrical and pneumatic analogue chart recorders for use in industrial-process control systems
NF EN 61535 : 2009 AMD 1 2013 INSTALLATION COUPLERS INTENDED FOR PERMANENT CONNECTION IN FIXED INSTALLATION
BS ISO 17089-1:2019 Measurement of fluid flow in closed conduits. Ultrasonic meters for gas Meters for custody transfer and allocation measurement
13/30267625 DC : 0 BS EN 61481-2 ED 1.0 - LIVE WORKING - PHASE COMPARATORS - PART 2: RESISTIVE TYPE TO BE USED FOR VOLTAGES FROM 1 KV TO 36 KV A.C
DIN EN ISO 13137:2014-03 Workplace atmospheres - Pumps for personal sampling of chemical and biological agents - Requirements and test methods (ISO 13137:2013)
12/30252220 DC : DRAFT MAR 2012 BS EN 62604-1 - SURFACE ACOUSTIC WAVE (SAW) AND BULK ACOUSTIC WAVE (BAW) DUPLEXERS - PART 1: GENERIC SPECIFICATION
PD IEC TR 60721-4-7:2001 Classification of environmental conditions. Guidance for the correlation and transformation of environmental condition classes of IEC 60721-3 to the environmental tests of IEC 60068 Portable and non-stationary use
BS EN 60086-5:2016 Primary batteries Safety of batteries with aqueous electrolyte
I.S. EN 60770-1:2011 TRANSMITTERS FOR USE IN INDUSTRIAL-PROCESS CONTROL SYSTEMS - PART 1: METHODS FOR PERFORMANCE EVALUATION
14/30297921 DC : 0 BS EN 62040-5-3 - UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 5-3: METHOD OF SPECIFYING THE PERFORMANCE AND TEST REQUIREMENTS FOR D.C. UPS
BS EN 62040-5-3:2017 Uninterruptible power systems (UPS) DC output UPS. Performance and test requirements
AAMI IEC 80601-2-30 : 2009 MEDICAL ELECTRICAL EQUIPMENT - PART 2-30: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF AUTOMATED NON-INVASIVE SPHYGMOMANOMETERS
BS EN 62745:2017 Safety of machinery. Requirements for cableless control systems of machinery
NF EN 60770-1 : 2011 TRANSMITTERS FOR USE IN INDUSTRIAL-PROCESS CONTROL SYSTEMS - PART 1: METHODS FOR PERFORMANCE EVALUATION
I.S. EN 50130-5:2011 ALARM SYSTEMS - PART 5: ENVIRONMENTAL TEST METHODS
PD IEC/TS 62735-1:2015 Direct current (DC) plugs and socket-outlets for information and communication technology (ICT) equipment installed in data centres and telecom central offices Plug and socket-outlet system for 2,6 kW
BS EN 61481-2:2014 Live working. Phase comparators Resistive type to be used for voltages from 1 kV to 36 kV a.c.
UNI EN ISO 80601-2-12 : 2011 MEDICAL ELECTRICAL EQUIPMENT - PART 2-12: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF CRITICAL CARE VENTILATORS
NF EN 61526 : 2013 RADIATION PROTECTION INSTRUMENTATION - MEASUREMENT OF PERSONAL DOSE EQUIVALENTS H[P](10) AND H[P](0,07) FOR X, GAMMA, NEUTRON AND BETA RADIATIONS - DIRECT READING PERSONAL DOSE EQUIVALENT METERS
09/30181956 DC : DRAFT MAY 2009 BS ISO 80601-2-61 - MEDICAL ELECTRICAL EQUIPMENT - PART 2-61: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF PULSE OXIMETER EQUIPMENT FOR MEDICAL USE
BS EN 62586-1:2017 Power quality measurement in power supply systems Power quality instruments (PQI)
BS ISO 17089-1:2010 Measurement of fluid flow in closed conduits. Ultrasonic meters for gas Meters for custody transfer and allocation measurement
BS EN 80601-2-30 : 2010 MEDICAL ELECTRICAL EQUIPMENT - PART 2-30: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF AUTOMATED NON-INVASIVE SPHYGMOMANOMETERS
BS EN 60068-2-27:2009 Environmental testing Tests. Test Ea and guidance. Shock
CEI EN 50467 : 2013 RAILWAY APPLICATIONS - ROLLING STOCK - ELECTRICAL CONNECTORS, REQUIREMENTS AND TEST METHODS
BS 7347:1990 Guide for characteristics and performance of mechanical shock testing machines
BS EN 45502-2-3:2010 Active implantable medical devices Particular requirements for cochlear and auditory brainstem implant systems
UNI EN 12405-1 : 2010 GAS METERS - CONVERSION DEVICES - PART 1: VOLUME CONVERSION
OIML R 144-2 : 2013 INSTRUMENTS FOR CONTINUOUS MEASUREMENT OF CO, NO[X] IN STATIONARY SOURCE EMISSIONS - PART 2: METROLOGICAL AND PERFORMANCE TESTS
12/30212889 DC : 0 BS ISO 13137 - WORKPLACE ATMOSPHERES - PUMPS FOR PERSONAL SAMPLING OF CHEMICAL AND BIOLOGICAL AGENTS - REQUIREMENTS AND TEST METHODS
I.S. EN 60335-1:2012 HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - SAFETY - PART 1: GENERAL REQUIREMENTS
CEI EN 60512-7-2 : 2012 CONNECTORS FOR ELECTRONIC EQUIPMENT - TESTS AND MEASUREMENTS - PART 7-2: IMPACT TESTS (FREE COMPONENTS) - TEST 7B: MECHANICAL STRENGTH IMPACT
CEI EN 61526 : 2013 RADIATION PROTECTION INSTRUMENTATION - MEASUREMENT OF PERSONAL DOSE EQUIVALENTS HP(10) AND HP(0,07) FOR X, GAMMA, NEUTRON AND BETA RADIATIONS - DIRECT READING PERSONAL DOSE EQUIVALENT METERS
BS EN 60068-2-55:2013 Environmental testing Tests. Test Ee and guidance. Loose cargo testing including bounce
BS 2011-2.1EE(1988) : 1988 AMD 7828 ENVIRONMENTAL TESTING - TESTS - TEST Ee. BOUNCE
NF EN 60601-1-11 : 2015 MEDICAL ELECTRICAL EQUIPMENT - PART 1-11: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - COLLATERAL STANDARD: REQUIREMENTS FOR MEDICAL ELECTRICAL EQUIPMENT AND MEDICAL ELECTRICAL SYSTEMS USED IN THE HOME HEALTHCARE ENVIRONMENT
UNE-EN 12405-3:2016 Gas meters - Conversion devices - Part 3: Flow computer
ISO 16750-3:2012 Road vehicles — Environmental conditions and testing for electrical and electronic equipment — Part 3: Mechanical loads
BS EN 61526:2013 Radiation protection instrumentation. Measurement of personal dose equivalents Hp(10) and Hp(0,07) for X, gamma, neutron and beta radiations. Direct reading personal dose equivalent meters
BS EN 61243-3:2014 Live working. Voltage detectors Two-pole low-voltage type
CSA C22.2 No. 60601-1-12 : 2015 MEDICAL ELECTRICAL EQUIPMENT - PART 1-12: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - COLLATERAL STANDARD: REQUIREMENTS FOR MEDICAL ELECTRICAL EQUIPMENT AND MEDICAL ELECTRICAL SYSTEMS INTENDED FOR USE IN THE EMERGENCY MEDICAL SERVICES ENVIRONMENT
IEC 61291-5-2:2017 Optical amplifiers - Part 5-2: Qualification specifications - Reliability qualification for optical fibre amplifiers
I.S. EN 62040-5-3:2017 UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 5-3: DC OUTPUT UPS - PERFORMANCE AND TEST REQUIREMENTS
EN 62884-1:2017 Measurement techniques of piezoelectric, dielectric and electrostatic oscillators - Part 1: Basic methods for the measurement
IEC 62884-1:2017 Measurement techniques of piezoelectric, dielectric and electrostatic oscillators - Part 1: Basic methods for the measurement
I.S. EN 60512-7-2:2012 CONNECTORS FOR ELECTRONIC EQUIPMENT - TESTS AND MEASUREMENTS - PART 7-2: IMPACT TESTS (FREE CONNECTORS) - TEST 7B: MECHANICAL STRENGTH IMPACT (IEC 60512-7-2:2011 (EQV))
I.S. EN 60728-6:2011 CABLE NETWORKS FOR TELEVISION SIGNALS, SOUND SIGNALS AND INTERACTIVE SERVICES - PART 6: OPTICAL EQUIPMENT
UNI EN ISO 80601-2-55 : 2012 MEDICAL ELECTRICAL EQUIPMENT - PART 2-55: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF RESPIRATORY GAS MONITORS
ISO 19453-3:2018 Road vehicles — Environmental conditions and testing for electrical and electronic equipment for drive system of electric propulsion vehicles — Part 3: Mechanical loads
CEI EN 60728-6 : 2012 CABLE NETWORKS FOR TELEVISION SIGNALS, SOUND SIGNALS AND INTERACTIVE SERVICES - PART 6: OPTICAL EQUIPMENT
IEC 60539-1:2016 Directly heated negative temperature coefficient thermistors - Part 1: Generic specification
I.S. EN 60728-3:2011 CABLE NETWORKS FOR TELEVISION SIGNALS, SOUND SIGNALS AND INTERACTIVE SERVICES - PART 3: ACTIVE WIDEBAND EQUIPMENT FOR CABLE NETWORKS
I.S. EN 61481-2:2014 LIVE WORKING - PHASE COMPARATORS - PART 2: RESISTIVE TYPE TO BE USED FOR VOLTAGES FROM 1 KV TO 36 KV A.C.
UNE-EN ISO 13137:2014 Workplace atmospheres - Pumps for personal sampling of chemical and biological agents - Requirements and test methods (ISO 13137:2013)
CSA C22.2 No. 80601-2-12 : 2012 MEDICAL ELECTRICAL EQUIPMENT - PART 2-12: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF CRITICAL CARE VENTILATORS
NF EN 60601-1-12 : 2015 MEDICAL ELECTRICAL EQUIPMENT - PART 1-12: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - COLLATERAL STANDARD: REQUIREMENTS FOR MEDICAL EQUIPMENT AND MEDICAL ELECTRICAL SYSTEMS INTENDED FOR USE THE EMERGENCY MEDICAL SERVICES ENVIRONMENT
I.S. EN 62040-3:2011 UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 3: METHOD OF SPECIFYING THE PERFORMANCE AND TEST REQUIREMENTS
IEC 61526:2010 Radiation protection instrumentation - Measurement of personal dose equivalents Hp(10) and Hp(0,07) for X, gamma, neutron and beta radiations - Direct reading personal dose equivalent meters
BS EN 14154-2 : 2005 WATER METERS - PART 2: INSTALLATION AND CONDITIONS OF USE
BS EN 61131-2:2007 Programmable controllers Equipment requirements and tests
IEC 62137-1-3:2008 Surface mounting technology - Environmental and endurance test methods for surface mount solder joint - Part 1-3: Cyclic drop test
EN 60065:2014/AC:2017-01 AUDIO, VIDEO AND SIMILAR ELECTRONIC APPARATUS - SAFETY REQUIREMENTS (IEC 60065:2014/COR2:2016)
IEC 60728-3:2017 Cable networks for television signals, sound signals and interactive services - Part 3: Active wideband equipment for cable networks
UNI EN 13718-1 : 2014 MEDICAL VEHICLES AND THEIR EQUIPMENT - AIR AMBULANCES - PART 1: REQUIREMENTS FOR MEDICAL DEVICES USED IN AIR AMBULANCES
I.S. EN ISO 14630:2012 NON-ACTIVE SURGICAL IMPLANTS - GENERAL REQUIREMENTS (ISO 14630:2012)
I.S. EN 60320-1:2015 Appliance couplers for household and similar general purposes - Part 1: General requirements
CSA C22.2 No. 60601-1-11 : 2015 MEDICAL ELECTRICAL EQUIPMENT - PART 1-11: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - COLLATERAL STANDARD: REQUIREMENTS FOR MEDICAL ELECTRICAL EQUIPMENT AND MEDICAL ELECTRICAL SYSTEMS USED IN THE HOME HEALTHCARE ENVIRONMENT
I.S. EN ISO 13137:2013 WORKPLACE ATMOSPHERES - PUMPS FOR PERSONAL SAMPLING OF CHEMICAL AND BIOLOGICAL AGENTS - REQUIREMENTS AND TEST METHODS (ISO 13137:2013)
01/206938 DC : DRAFT OCT 2001 IEC 60255-27 ED.1.0 - MEASURING RELAYS AND EQUIPMENT - PART 27: PRODUCT SAFETY REQUIREMENTS FOR MEASURING RELAYS AND PROTECTION EQUIPMENT
OIML R 140 : 2007 MEASURING SYSTEMS FOR GASEOUS FUEL
IEC 62745:2017 Safety of machinery - Requirements for cableless control systems of machinery
BS EN 60728-14:2014 Cable networks for television signals, sound signals and interactive services Optical transmission systems using RFoG technology
ISO 11614:1999 Reciprocating internal combustion compression-ignition engines Apparatus for measurement of the opacity and for determination of the light absorption coefficient of exhaust gas
09/30197590 DC : 0 BS EN ISO 80601-2-55 - MEDICAL ELECTRICAL EQUIPMENT - PART 2-55: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF RESPIRATORY GAS MONITORS
13/30285624 DC : 0 BS EN ISO 16061 - INSTRUMENTATION FOR USE IN ASSOCIATION WITH NON-ACTIVE SURGICAL IMPLANTS - GENERAL REQUIREMENTS
13/30289289 DC : 0 BS EN 12405-3 - GAS METERS - CONVERSION DEVICES - PART 3: FLOW COMPUTER
14/30296572 DC : 0 BS EN 60601-1-11 - MEDICAL ELECTRICAL EQUIPMENT - PART 1-11: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - COLLATERAL STANDARD: REQUIREMENTS FOR MEDICAL ELECTRICAL EQUIPMENT AND MEDICAL ELECTRICAL SYSTEMS USED IN THE HOME HEALTHCARE ENVIRONMENT
BS EN ISO 4064-2:2017 Water meters for cold potable water and hot water Test methods
BS ISO 8568:2007 Mechanical shock. Testing machines. Characteristics and performance
ISO 18185-3:2015 Freight containers Electronic seals Part 3: Environmental characteristics
NF EN 60846-1 : 2015 RADIATION PROTECTION INSTRUMENTATION - AMBIENT AND/OR DIRECTIONAL DOSE EQUIVALENT (RATE) METERS AND/OR MONITORS FOR BETA, X AND GAMMA RADIATION - PART 1: PORTABLE WORKPLACE AND ENVIRONMENTAL METERS AND MONITORS
UNE-EN 61481-1:2015 Live working - Phase comparators - Part 1: Capacitive type to be used for voltages exceeding 1 kV a.c.
UNE-EN 62586-1:2014 Power quality measurement in power supply systems - Part 1: Power quality instruments (PQI)
BS ISO 19453-3:2018 Road vehicles. Environmental conditions and testing for electrical and electronic equipment for drive system of electric propulsion vehicles Mechanical loads
I.S. EN 61514-2:2013 INDUSTRIAL PROCESS CONTROL SYSTEMS - PART 2: METHODS OF EVALUATING THE PERFORMANCE OF INTELLIGENT VALVE POSITIONERS WITH PNEUMATIC OUTPUTS MOUNTED ON AN ACTUATOR VALVE ASSEMBLY (IEC 61514-2:2013 (EQV))
UNI CEI EN ISO 4064-2 : 2014 WATER METERS FOR COLD POTABLE WATER AND HOT WATER - PART 2: TEST METHODS
DIN EN ISO 4064-2:2016-09 (Draft) WATER METERS FOR COLD POTABLE WATER AND HOT WATER - PART 2: TEST METHODS (ISO 4064-2:2014)
ISO 9022-3:2015 Optics and photonics Environmental test methods Part 3: Mechanical stress
BS ISO 18185-3:2006 Freight containers. Electronic seals Environmental characteristics
CEI EN 60546-1 : 2011 CONTROLLERS WITH ANALOGUE SIGNALS FOR USE IN INDUSTRIAL-PROCESS CONTROL SYSTEMS - PART 1: METHODS OF EVALUATING THE PERFORMANCE
11/30244681 DC : 0 BS IEC 62706 - RADIATION PROTECTION INSTRUMENTATION - ENVIRONMENTAL, ELECTROMAGNETIC AND MECHANICAL PERFORMANCE REQUIREMENTS
I.S. EN 60086-5:2016 PRIMARY BATTERIES - PART 5: SAFETY OF BATTERIES WITH AQUEOUS ELECTROLYTE
CEI EN 62745 : 1ED 2017 SAFETY OF MACHINERY - REQUIREMENTS FOR CABLELESS CONTROL SYSTEMS OF MACHINERY
BS EN ISO 13137:2013 Workplace atmospheres — Pumps for personal sampling of chemical and biological agents — Requirements and test methods
PD IEC/TS 62257-3:2015 Recommendations for renewable energy and hybrid systems for rural electrification Project development and management
OIML R 137-1 : 2006 GAS METERS - PART 1: REQUIREMENTS
04/30124466 DC : DRAFT OCT 2004 EN 12405-1 - GAS METERS - CONVERSION DEVICES - PART 1: VOLUME CONVERSION
BS ISO 9022-3:2015 Optics and photonics. Environmental test methods Mechanical stress
15/30326894 DC : 0 BS EN 60086-5 ED 4.0 - PRIMARY BATTERIES - PART 5: SAFETY OF BATTERIES WITH AQUEOUS ELECTROLYTE
15/30294923 DC : 0 BS EN 61291-5-2 ED2.0 - OPTICAL AMPLIFIERS - PART 5-2: QUALIFICATION SPECIFICATIONS - RELIABILITY QUALIFICATION FOR OPTICAL FIBRE AMPLIFIERS
ISA S82.01 : 1994 ELECTRICAL AND ELECTRONIC TEST, MEASURING, CONTROLLING AND RELATED EQUIPMENT - GENERAL REQUIREMENTS
BS EN 60512-7-2:2012 Connectors for electronic equipment. Tests and measurements Impact tests (free connectors). Test 7b. Mechanical strength impact
CEI EN 62884-1 : 1ED 2018 MEASUREMENT TECHNIQUES OF PIEZOELECTRIC, DIELECTRIC AND ELECTROSTATIC OSCILLATORS - PART 1: BASIC METHODS FOR THE MEASUREMENT
EN 62040-3:2011 Uninterruptible power systems (UPS) - Part 3: Method of specifying the performance and test requirements
I.S. EN ISO 80601-2-12:2011 MEDICAL ELECTRICAL EQUIPMENT - PART 2-12: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF CRITICAL CARE VENTILATORS (ISO 80601-2-12:2011/COR 1:2011)
IEC TR 61916:2017 Electrical accessories - Harmonization of general rules
CSA C22.2 No. 80601-2-30 : 2010 : INC : COR 1 : 2011 MEDICAL ELECTRICAL EQUIPMENT - PART 2-30: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF AUTOMATED NON-INVASIVE SPHYGMOMANOMETERS
I.S. EN 50637:2017 MEDICAL ELECTRICAL EQUIPMENT - PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF MEDICAL BEDS FOR CHILDREN
BS EN 60601-2-52 : 2010 MEDICAL ELECTRICAL EQUIPMENT - PART 2-52: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF MEDICAL BEDS
CSA C22.2 No. 80601-2-30 : 2010FR MEDICAL ELECTRICAL EQUIPMENT - PART 2-30: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF AUTOMATED NON-INVASIVE SPHYGMOMANOMETERS
CSA C22.2 No. 80601-2-30 : 2010 : R2015 MEDICAL ELECTRICAL EQUIPMENT - PART 2-30: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF AUTOMATED NON-INVASIVE SPHYGMOMANOMETERS
ISO 17089-1:2010 Measurement of fluid flow in closed conduits - Ultrasonic meters for gas Part 1: Meters for custody transfer and allocation measurement
CEI EN 60770-1 : 2014 TRANSMITTERS FOR USE IN INDUSTRIAL-PROCESS CONTROL SYSTEMS - PART 1: METHODS FOR PERFORMANCE EVALUATION
I.S. EN 60846-1:2014 RADIATION PROTECTION INSTRUMENTATION - AMBIENT AND/OR DIRECTIONAL DOSE EQUIVALENT (RATE) METERS AND/OR MONITORS FOR BETA, X AND GAMMA RADIATION - PART 1: PORTABLE WORKPLACE AND ENVIRONMENTAL METERS AND MONITORS
I.S. EN 62752:2016/AC:2019-03 IN-CABLE CONTROL AND PROTECTION DEVICE FOR MODE 2 CHARGING OF ELECTRIC ROAD VEHICLES (IC-CPD)
I.S. EN 80601-2-30:2010 MEDICAL ELECTRICAL EQUIPMENT - PART 2-30: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF AUTOMATED NON-INVASIVE SPHYGMOMANOMETERS
I.S. EN 12405-3:2015 GAS METERS - CONVERSION DEVICES - PART 3: FLOW COMPUTER
I.S. EN 60601-1-12:2015 MEDICAL ELECTRICAL EQUIPMENT - PART 1-12: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - COLLATERAL STANDARD: REQUIREMENTS FOR MEDICAL ELECTRICAL EQUIPMENT AND MEDICAL ELECTRICAL SYSTEMS INTENDED FOR USE IN THE EMERGENCY MEDICAL SERVICES ENVIRONMENT
BS EN 60335-1 : 2012 HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - SAFETY - PART 1: GENERAL REQUIREMENTS (IEC 60335-1:2010, MODIFIED)
ISO 17363:2013 Supply chain applications of RFID Freight containers
I.S. EN 12405-1:2005 GAS METERS - CONVERSION DEVICES - PART 1: VOLUME CONVERSION
I.S. EN 61526:2013 RADIATION PROTECTION INSTRUMENTATION - MEASUREMENT OF PERSONAL DOSE EQUIVALENTS H[P](10) AND H[P](0,07) FOR X, GAMMA, NEUTRON AND BETA RADIATIONS - DIRECT READING PERSONAL DOSE EQUIVALENT METERS (IEC 61526:2010 (MOD))
UNE-EN 61481-2:2015 Live working - Phase comparators - Part 2: Resistive type to be used for voltages from 1 kV to 36 kV a.c.
OIML R 49-2 : 2013 WATER METERS FOR COLD POTABLE WATER AND HOT WATER - PART 2: TEST METHODS
OIML R 35-2 : 2011 MATERIAL MEASURES OF LENGTH FOR GENERAL USE - PART 2: TEST METHODS
CEI EN 60068-2-27 : 2012 ENVIRONMENTAL TESTING - PART 2-27: TESTS - TEST EA AND GUIDANCE: SHOCK
IEC 61558-1:2017 Safety of transformers, reactors, power supply units and combinations thereof - Part 1: General requirements and tests
NF EN 61010-2-201 : 2013 SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL, AND LABORATORY USE - PART 2-201: PARTICULAR REQUIREMENTS FOR CONTROL EQUIPMENT
I.S. EN 62884-1:2017 MEASUREMENT TECHNIQUES OF PIEZOELECTRIC, DIELECTRIC AND ELECTROSTATIC OSCILLATORS - PART 1: BASIC METHODS FOR THE MEASUREMENT
OIML R 126 : 2012 EVIDENTIAL BREATH ANALYZERS
EN ISO 80601-2-61:2011 Medical electrical equipment - Part 2-61: Particular requirements for basic safety and essential performance of pulse oximeter equipment (ISO 80601-2-61:2011)
IEC 60068-2-27:2008 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
IEC 60728-3:2017 RLV Cable networks for television signals, sound signals and interactive services - Part 3: Active wideband equipment for cable networks
IEC TR 60721-4-2:2001+AMD1:2003 CSV Classification of environmental conditions - Part 4-2: Guidance for the correlation and transformation of environmental condition classes of IEC 60721-3 to the environmental tests of IEC 60068 - Transportation
IEC 62103:2003 Electronic equipment for use in power installations
IEC 60780:1998 Nuclear power plants - Electrical equipment of the safety system - Qualification
DIN EN 13718-1:2014-12 MEDICAL VEHICLES AND THEIR EQUIPMENT - AIR AMBULANCES - PART 1: REQUIREMENTS FOR MEDICAL DEVICES USED IN AIR AMBULANCES
IEC 62604-1:2015 Surface acoustic wave (SAW) and bulk acoustic wave (BAW) duplexers of assessed quality - Part 1: Generic specification
IEC 61514-2:2013 Industrial process control systems - Part 2: Methods of evaluating the performance of intelligent valve positioners with pneumatic outputs mounted on an actuator valve assembly
IEC 62575-1:2015 Radio frequency (RF) bulk acoustic wave (BAW) filters of assessed quality - Part 1: Generic specification
UNE-EN 61535:2010 Installation couplers intended for permanent connection in fixed installations
UNE-EN 14154-2:2005 Water meters - Part 2 : Installation and conditions of use
EN 60601-1-12:2015 Medical electrical equipment - Part 1-12: General requirements for basic safety and essential performance - Collateral Standard: Requirements for medical electrical equipment and medical electrical systems intended for use in the emergency medical services environment
CSA C22.2 No. 80601-2-12 : 2012(R2017) MEDICAL ELECTRICAL EQUIPMENT - PART 2-12: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF CRITICAL CARE VENTILATORS
EN 60086-4:2015 Primary batteries - Part 4: Safety of lithium batteries
EN 60601-2-52:2010/A1:2015 MEDICAL ELECTRICAL EQUIPMENT - PART 2-52: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF MEDICAL BEDS
UNI EN 14154-2 : 2011 WATER METERS - PART 2: INSTALLATION AND CONDITIONS OF USE
UNI CEI EN 45502-2-3 : 2010 ACTIVE IMPLANTABLE MEDICAL DEVICES - PART 2-3: PARTICULAR REQUIREMENTS FOR COCHLEAR AND AUDITORY BRAINSTEM IMPLANT SYSTEMS
UNI EN ISO 14630 : 2013 NON-ACTIVE SURGICAL IMPLANTS - GENERAL REQUIREMENTS
DIN EN ISO 16061:2015-09 Instrumentation for use in association with non-active surgical implants - General requirements (ISO 16061:2015)
11/30217192 DC : 0 BS EN ISO 4064-2 - WATER METERS INTENDED FOR THE METERING OF COLD POTABLE WATER AND HOT WATER - PART 2: TEST METHODS
UNE-EN 60068-2-27:2011 Environmental testing -- Part 2-27: Tests - Test Ea and guidance: Shock
ANSI/AAMI HA60601-1-11:2015 MEDICAL ELECTRICAL EQUIPMENT - PART 1-11: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - COLLATERAL STANDARD: REQUIREMENTS FOR MEDICAL ELECTRICAL EQUIPMENT AND MEDICAL ELECTRICAL SYSTEMS USED IN THE HOME HEALTHCARE ENVIRONMENT
IEC TS 62257-3:2015 Recommendations for renewable energy and hybrid systems for rural electrification - Part 3: Project development and management
IEC 60846-1:2009 Radiation protection instrumentation - Ambient and/or directional dose equivalent (rate) meters and/or monitors for beta, X and gamma radiation - Part 1: Portable workplace and environmental meters and monitors
BS EN 62604-1:2015 Surface acoustic wave (SAW) and bulk acoustic wave (BAW) duplexers of assessed quality Generic specification
08/30176946 DC : DRAFT JAN 2008 BS EN 60770-1 - TRANSMITTERS FOR USE IN INDUSTRIAL-PROCESS CONTROL SYSTEMS - PART 1: METHODS FOR PERFORMANCE EVALUATION
BS EN 60689:2009 Measurement and test methods for tuning fork quartz crystal units in the range from 10 kHz to 200 kHz and standard values
CEI 45-60 : 2009 NUCLEAR POWER PLANTS - ELECTRICAL EQUIPMENT OF THE SAFETY SYSTEM - QUALIFICATION
17/30296020 DC : 0 BS ISO 19453-3 - ROAD VEHICLES - ENVIRONMENTAL CONDITIONS AND TESTING FOR ELECTRICAL AND ELECTRONIC EQUIPMENT FOR DRIVE SYSTEM OF ELECTRIC PROPULSION VEHICLES - PART 3: MECHANICAL LOADS
CEI EN 61514 : 2002 INDUSTRIAL-PROCESS CONTROL SYSTEMS - METHODS OF EVALUATING THE PERFORMANCE OF VALVE POSITIONERS WITH PNEUMATIC OUTPUTS
CEI EN 60068-2-55 : 2014 ENVIRONMENTAL TESTING - PART 2-55: TESTS - TEST EE AND GUIDANCE: LOOSE CARGO TESTING INCLUDING BOUNCE
05/30138371 DC : DRAFT AUG 2005 IEC 60068-2-27 ED 4 - BASIC ENVIRONMENTAL TESTING PROCEDURES - PART 2-27: TESTS - TEST EA AND GUIDANCE - SHOCK AND BUMP
11/30243761 DC : 0 BS ISO 14708-7 - IMPLANTS FOR SURGERY - ACTIVE IMPLANTABLE MEDICAL DEVICES - PART 7: PARTICULAR REQUIREMENTS FOR COCHLEAR IMPLANT SYSTEMS
DIN ISO 9022-3:2015-08 Optics and photonics - Environmental test methods - Part 3: Mechanical stress (ISO 9022-3:2015)
14/30282284 DC : 0 BS ISO 18185-3 - FREIGHT CONTAINERS - ELECTRONIC SEALS - PART 3: ENVIRONMENTAL CHARACTERISTICS
I.S. EN 61535:2009 INSTALLATION COUPLERS INTENDED FOR PERMANENT CONNECTION IN FIXED INSTALLATIONS (IEC 61535:2009 (EQV))
BS EN 62488-2:2017 Power line communication systems for power utility applications Analogue power line carrier terminals or APLC
15/30280758 DC : 0 BS EN 62745 - SAFETY OF MACHINERY - GENERAL REQUIREMENTS FOR CABLELESS CONTROL SYSTEMS OF MACHINERY
BS EN 12405-3:2015 Gas meters. Conversion devices Flow computer
CEI EN 62137-1-3 : 2009 SURFACE MOUNTING TECHNOLOGY - ENVIRONMENTAL AND ENDURANCE TEST METHODS FOR SURFACE MOUNT SOLDER JOINT - PART 1-3: CYCLIC DROP TEST
OIML R 99-1 & 2 : 2008 INSTRUMENTS FOR MEASURING VEHICLE EXHAUST EMISSIONS - PART 1: METROLOGICAL AND TECHNICAL REQUIREMENTS; PART 2: METROLOGICAL CONTROLS AND PERFORMANCE TESTS
12/30245174 DC : 0 BS EN 60601-1-12 - MEDICAL ELECTRICAL EQUIPMENT - PART 1-12: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - COLLATERAL STANDARD: REQUIREMENTS FOR MEDICAL ELECTRICAL EQUIPMENT AND MEDICAL ELECTRICAL SYSTEMS INTENDED FOR USE IN THE EMERGENCY MEDICAL SERVICES ENVIRONMENT
BS EN 60770-3:2014 Transmitters for use in industrial-process control systems Methods for performance evaluation of intelligent transmitters
13/30264600 DC : 0 BS EN 60747-14-8 ED 1.0 - SEMICONDUCTOR DEVICES - PART 14-8: SEMICONDUCTOR SENSORS - CAPACITIVE DEGRADATION SENSOR OF LIQUID
13/30267621 DC : 0 BS EN 61481-1 ED 1.0 - LIVE WORKING - PHASE COMPARATORS - PART 1: CAPACITIVE TYPE TO BE USED FOR VOLTAGES EXCEEDING 1 KV A.C.
09/30155521 DC : 0 BS EN 60601-1-11 ED.1 - MEDICAL ELECTRICAL EQUIPMENT - PART 1-11: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - COLLATERAL STANDARD: REQUIREMENTS FOR MEDICAL ELECTRICAL EQUIPMENT AND MEDICAL ELECTRICAL SYSTEMS USED IN THE HOME HEALTHCARE ENVIRONMENT
14/30257546 DC : 0 BS ISO 17966 - ASSISTIVE PRODUCTS FOR PERSONAL HYGIENE THAT SUPPORT USERS - REQUIREMENTS AND TEST METHODS
BS EN 62387-1:2012 Radiation protection instrumentation. Passive integrating dosimetry systems for environmental and personal monitoring General characteristics and performance requirements
UNE-EN 60065:2015 Audio, video and similar electronic apparatus - Safety requirements
02/707208 DC : DRAFT MAY 2002 ISO/DIS 8568 - MECHANICAL SHOCK - TESTING MACHINES - CHARACTERISTICS AND PERFORMANCE
BS HD 60269-3 : 2010 LOW-VOLTAGE FUSES - PART 3: SUPPLEMENTARY REQUIREMENTS FOR FUSES FOR USE BY UNSKILLED PERSONS (FUSES MAINLY FOR HOUSEHOLD AND SIMILAR APPLICATIONS) - EXAMPLES OF STANDARDIZED SYSTEMS OF FUSES A TO F
PREN 50130-5 : DRAFT 2010 ALARM SYSTEMS - PART 5: ENVIRONMENTAL TEST METHODS
PREN ISO 80601-2-55 : DRAFT 2009 MEDICAL ELECTRICAL EQUIPMENT - PART 2-55: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF RESPIRATORY GAS MONITORS
CSA C22.2 No. 60065 : 2016 AUDIO, VIDEO AND SIMILAR ELECTRONIC APPARATUS - SAFETY REQUIREMENTS
BS EN 50130-5:2011 Alarm systems Environmental test methods
BS EN 60770-1:1999 Transmitters for use in industrial-process control systems Methods for performance evaluation
PD 6521:1988 Summaries of test methods for environmental testing of electrotechnical products
04/30031075 DC : DRAFT FEB 2004 ISO 4064-1 - MEASUREMENT OF WATER FLOW IN CLOSED FULLY CHARGED CONDUITS - METERS FOR COLD POTABLE WATER AND HOT WATER - PART 1: SPECIFICATIONS
NF EN 60068 2-29 : 1994 BASIC ENVIRONMENTAL TESTING PROCEDURES - PART 2: TESTS - TEST EB AND GUIDANCE: BUMP
NF EN ISO 80601-2-12 : 2011 MEDICAL ELECTRICAL EQUIPMENT - PART 2-12: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF CRITICAL CARE VENTILATORS
IEC 62828-1:2017 Reference conditions and procedures for testing industrial and process measurement transmitters - Part 1: General procedures for all types of transmitters
EN 300 019-2-2 : 2.3.1 ENVIRONMENTAL ENGINEERING (EE); ENVIRONMENTAL CONDITIONS AND ENVIRONMENTAL TESTS FOR TELECOMMUNICATIONS EQUIPMENT; PART 2-2: SPECIFICATION OF ENVIRONMENTAL TESTS; TRANSPORTATION
BS EN ISO 16061:2015 Instrumentation for use in association with non-active surgical implants. General requirements
BS ISO 16750-3:2012 Road vehicles. Environmental conditions and testing for electrical and electronic equipment Mechanical loads
15/30327720 DC : 0 BS EN 62586-1 - POWER QUALITY MEASUREMENT IN POWER SUPPLY SYSTEMS - PART 1: POWER QUALITY INSTRUMENTS (PQI)
UNE-EN 60086-5:2011 Primary batteries - Part 5: Safety of batteries with aqueous electrolyte
BS EN 62040-3:2011 Uninterruptible power systems (UPS) Method of specifying the performance and test requirements
BS EN 61298-3:2008 Process measurement and control devices. General methods and procedures for evaluating performance Tests for the effects of influence quantities
NF ISO 3930 : 2001 INSTRUMENTS FOR MEASURING VEHICLE EXHAUST EMISSIONS
CEI EN 62040-5-3 : 1ED 2017 UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 5-3: DC OUTPUT UPS - PERFORMANCE AND TEST REQUIREMENTS
I.S. EN 60065:2014 AUDIO, VIDEO AND SIMILAR ELECTRONIC APPARATUS - SAFETY REQUIREMENTS
I.S. EN 60086-4:2015 PRIMARY BATTERIES - PART 4: SAFETY OF LITHIUM BATTERIES
EN 62488-2:2017 Power line communication systems for power utility applications - Part 2: Analogue power line carrier terminals or APLC
UNE-EN 60320-1:2016 Appliance couplers for household and similar general purposes - Part 1: General requirements
I.S. EN ISO 4064-2:2017 WATER METERS FOR COLD POTABLE WATER AND HOT WATER - PART 2: TEST METHODS (ISO 4064-2:2014)
IEC 60770-3:2014 Transmitters for use in industrial-process control systems - Part 3: Methods for performance evaluation of intelligent transmitters
I.S. EN 61291-5-2:2017 OPTICAL AMPLIFIERS - PART 5-2: QUALIFICATION SPECIFICATIONS - RELIABILITY QUALIFICATION FOR OPTICAL FIBRE AMPLIFIERS
I.S. EN 61243-3:2014 LIVE WORKING - VOLTAGE DETECTORS - PART 3: TWO-POLE LOW-VOLTAGE TYPE
EN IEC 62828-1:2018 Reference conditions and procedures for testing industrial and process measurement transmitters - Part 1: General procedures for all types of transmitters
CEI 32-13 : 2013 LOW-VOLTAGE FUSES - PART 3: SUPPLEMENTARY REQUIREMENTS FOR FUSES FOR USE BY UNSKILLED PERSONS (FUSES MAINLY FOR HOUSEHOLD AND SIMILAR APPLICATIONS) - EXAMPLES OF STANDARDIZED SYSTEMS OF FUSES A TO F
ISO 8568:2007 Mechanical shock Testing machines Characteristics and performance
I.S. EN 60068-2-27:2009 ENVIRONMENTAL TESTING - PART 2-27: TESTS - TEST EA AND GUIDANCE: SHOCK
IEC 62847:2016 Railway applications - Rolling stock - Electrical connectors - Requirements and test methods
EN 12405-1:2005+A2:2010 Gas meters - Conversion devices - Part 1: Volume conversion
IEC 62586-1:2017 Power quality measurement in power supply systems - Part 1: Power quality instruments (PQI)
I.S. EN 60601-2-52:2010 MEDICAL ELECTRICAL EQUIPMENT - PART 2-52: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF MEDICAL BEDS (IEC 60601-2-52:2009)
IEC 60269-3:2010+AMD1:2013+AMD2:2019 CSV Low-voltage fuses - Part 3: Supplementary requirements for fuses for use by unskilled persons (fuses mainly for household or similar applications) - Examples of standardized systems of fuses A to F
I.S. EN 62137-1-3:2009 SURFACE MOUNTING TECHNOLOGY - ENVIRONMENTAL AND ENDURANCE TEST METHODS FOR SURFACE MOUNT SOLDER JOINT - PART 1-3: CYCLIC DROP TEST
I.S. EN 61131-2:2007 PROGRAMMABLE CONTROLLERS - PART 2: EQUIPMENT REQUIREMENTS AND TESTS
I.S. EN 60068-2-47:2005 ENVIRONMENTAL TESTING - PART 2-47: TESTS - MOUNTING OF SPECIMENS FOR VIBRATION, IMPACT AND SIMILAR DYNAMIC TESTS
ISO 7752-1:2010 Cranes Control layout and characteristics Part 1: General principles
IEC 61131-2:2017 Industrial-process measurement and control - Programmable controllers - Part 2: Equipment requirements and tests
EN 60539-1:2016/AC:2017-09 DIRECTLY HEATED NEGATIVE TEMPERATURE COEFFICIENT THERMISTORS - PART 1: GENERIC SPECIFICATION (IEC 60539-1:2016/COR1:2017)
EN 61010-2-201:2013/AC:2013 SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL AND LABORATORY USE - PART 2-201: PARTICULAR REQUIREMENTS FOR CONTROL EQUIPMENT (IEC 61010-2-201:2013)
ISO 80601-2-12:2011 Medical electrical equipment Part 2-12: Particular requirements for basic safety and essential performance of critical care ventilators
DIN EN ISO 14630:2013-03 Non-active surgical implants - General requirements (ISO 14630:2012)
BS EN 12919:1999 Workplace atmospheres. Pumps for the sampling of chemical agents with a volume flow rate of over 51/min. Requirements and test methods
IEC 60689:2008 Measurement and test methods for tuning fork quartz crystal units in the range from 10 kHz to 200 kHz and standard values
IEC 60728-14:2014 Cable networks for television signals, sound signals and interactive services - Part 14: Optical transmission systems using RFoG technology
ISO 16061:2015 Instrumentation for use in association with non-active surgical implants General requirements
IEC 60320-1:2015 Appliance couplers for household and similar general purposes - Part 1: General requirements
EN 62752:2016 In-cable control and protection device for mode 2 charging of electric road vehicles (IC-CPD)
ISO 4064-2:2014 Water meters for cold potable water and hot water — Part 2: Test methods
EN 13718-1:2014 Medical vehicles and their equipment - Air ambulances - Part 1: Requirements for medical devices used in air ambulances
IEC 62040-5-3:2016 Uninterruptible power systems (UPS) - Part 5-3: DC output UPS - Performance and test requirements
I.S. EN 13718-1:2014 MEDICAL VEHICLES AND THEIR EQUIPMENT - AIR AMBULANCES - PART 1: REQUIREMENTS FOR MEDICAL DEVICES USED IN AIR AMBULANCES
IEC 60512-7-2:2011 Connectors for electronic equipment - Tests and measurements - Part 7-2: Impact tests (free components) - Test 7b: Mechanical strength impact
IEC 61535:2009+AMD1:2012 CSV Installation couplers intended for permanent connection in fixedinstallations
IEC 60728-6:2011 Cable networks for television signals, sound signals and interactive services - Part 6: Optical equipment
IEC 61747-1:1998+AMD1:2003 CSV Liquid crystal and solid-state display devices - Part 1: Generic specification
IEC 60862-1:2015 Surface acoustic wave (SAW) filters of assessed quality - Part 1: Generic specification
IEC 60770-1:2010 Transmitters for use in industrial-process control systems - Part 1: Methods for performance evaluation
IEC 60068-2-47:2005 Environmental testing - Part 2-47: Test - Mounting of specimens for vibration, impact and similar dynamic tests
IEC 62040-3:2011 Uninterruptible power systems (UPS) - Part 3: Method of specifying the performance and test requirements
IEC 61243-3:2014 Live working - Voltage detectors - Part 3: Two-pole low-voltage type
ISO 13137:2013 Workplace atmospheres — Pumps for personal sampling of chemical and biological agents — Requirements and test methods
IEC 61298-3:2008 Process measurement and control devices - General methods and procedures for evaluating performance - Part 3: Tests for the effects of influence quantities
UNE-EN ISO 14630:2013 Non-active surgical implants - General requirements (ISO 14630:2012)
UNE-EN 45502-2-3:2010 Active implantable medical devices -- Part 2-3: Particular requirements for cochlear and auditory brainstem implant systems
13/30267440 DC : 0 BS EN 60086-4 ED 4.0 - PRIMARY BATTERIES - PART 4: SAFETY OF LITHIUM BATTERIES
BS EN 12405:2002 Gas meters. Gas-volume electronic conversion devices
UNE-EN 60335-1:2012 Household and similar electrical appliances - Safety - Part 1: General requirements
IEC 60884-1:2002+AMD1:2006+AMD2:2013 CSV Plugs and socket-outlets for household and similar purposes - Part1: General requirements
IEC 60546-1:2010 Controllers with analogue signals for use in industrial-process control systems - Part 1: Methods of evaluating the performance
IEC 61481-2:2014 Live working - Phase comparators - Part 2: Resistive type to be used for voltages from 1kV to 36 kV a.c.
UNE-EN 61243-3:2015 Live working - Voltage detectors - Part 3: Two-pole low-voltage type
IEC 60601-2-52:2009+AMD1:2015 CSV Medical electrical equipment - Part 2-52: Particular requirements for the basic safety and essential performance of medical beds
IEC 60086-4:2014 Primary batteries - Part 4: Safety of lithium batteries
EN 60320-1:2015/AC:2016 APPLIANCE COUPLERS FOR HOUSEHOLD AND SIMILAR GENERAL PURPOSES - PART 1: GENERAL REQUIREMENTS (IEC 60320-1:2015/COR1:2016)
EN 60862-1:2015 Surface acoustic wave (SAW) filters of assessed quality - Part 1: Generic specification
EN 61526:2013 Radiation protection instrumentation - Measurement of personal dose equivalents Hp(10) and Hp(0,07) for X, gamma, neutron and beta radiations - Direct reading personal dose equivalent meters
EN 14154-2:2005+A2:2011 Water meters - Part 2: Installation and conditions of use
EN ISO 4064-2:2017 Water meters for cold potable water and hot water - Part 2: Test methods (ISO 4064-2:2014)
EN 45502-2-3:2010 Active implantable medical devices - Part 2-3: Particular requirements for cochlear and auditory brainstem implant systems
EN ISO 14630:2012 Non-active surgical implants - General requirements (ISO 14630:2012)
I.S. EN ISO 80601-2-61:2011 MEDICAL ELECTRICAL EQUIPMENT - PART 2-61: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF PULSE OXIMETER EQUIPMENT
ISO 80601-2-61:2017 Medical electrical equipment Part 2-61: Particular requirements for basic safety and essential performance of pulse oximeter equipment
BS EN 61481-1:2014 Live working. Phase comparators Capacitive type to be used for voltages exceeding 1 kV a.c.
BS EN 60846-1:2014 Radiation protection instrumentation. Ambient and/or directional dose equivalent (rate) meters and/or monitors for beta, X and gamma radiation Portable workplace and environmental meters and monitors
DIN EN 12405-3:2016-04 Gas meters - Conversion devices - Part 3: Flow computer
BS EN 50637:2017 Medical electrical equipment. Particular requirements for the basic safety and essential performance of medical beds for children
BS EN 62137-1-3:2009 Surface mounting technology. Environmental and endurance test methods for surface mount solder joint Cyclic drop test
11/30243576 DC : DRAFT FEB 2011 BS EN 62643-1 - ELECTROSTATIC MICRO ELECTRO MECHANICAL SYSTEMS (MEMS) OSCILLATORS OF ASSESSED QUALITY - PART 1: GENERIC SPECIFICATION
BS EN 60728-6:2011 Cable networks for television signals, sound signals and interactive services Optical equipment
BS IEC 60780:1998 Nuclear power plants. Electrical equipment of the safety system. Qualification
UNE-ISO 15817:2013 Earth-moving machinery. Safety requirements for remote operator control systems
BS EN 60546-1:2010 Controllers with analogue signals for use in industrial-process control systems Methods of evaluating the performance
CEI EN 62586-1 : 2016 POWER QUALITY MEASUREMENT IN POWER SUPPLY SYSTEMS - PART 1: POWER QUALITY INSTRUMENTS (PQI)
BS EN 60728-3:2011 Cable networks for television signals, sound signals and interactive services Active wideband equipment for cable networks
CEI EN 62752 : 1ED 2017 IN-CABLE CONTROL AND PROTECTION DEVICE FOR MODE 2 CHARGING OF ELECTRIC ROAD VEHICLES (IC-CPD)
IEC 62599-1:2010 Alarm systems - Part 1: Environmental test methods
UNE-EN 50130-5:2011 Alarm systems - Part 5: Environmental test methods
13/30264596 DC : 0 BS EN 60747-14-7 ED 1.0 - SEMICONDUCTOR DEVICES - PART 14-7: SEMICONDUCTOR SENSORS - FLOW METER
98/262470 DC : DRAFT JUL 1998 IEC 61987 ED. 1 - TERMS AND STRUCTURES OF MEASURING EQUIPMENT
BS 88-3(2010) : 2010 COR 2014 LOW-VOLTAGE FUSES - PART 3: SUPPLEMENTARY REQUIREMENTS FOR FUSES FOR USE BY UNSKILLED PERSONS (FUSES MAINLY FOR HOUSEHOLD AND SIMILAR APPLICATIONS) - EXAMPLES OF STANDARDIZED SYSTEMS OF FUSES A TO F
UNI ISO 7752-1 : 2011 CRANES - CONTROL LAYOUT AND CHARACTERISTICS - PART 1: GENERAL PRINCIPLES
BS IEC 62706:2012 Radiation protection instrumentation. Environmental, electromagnetic and mechanical performance requirements
BS EN 50467:2011 Railway applications. Rolling stock. Electrical connectors, requirements and test methods
03/311340 DC : DRAFT JULY 2003 IEC 60728-3 ED.3.0 - CABLE NETWORKS FOR TELEVISION SIGNALS, SOUND SIGNALS AND INTERACTIVE SERVICES - PART 3: ACTIVE COAXIAL WIDEBAND DISTRIBUTION EQUIPMENT (TA5)
08/30157876 DC : 0
I.S. EN 62387-1:2012 RADIATION PROTECTION INSTRUMENTATION - PASSIVE INTEGRATING DOSIMETRY SYSTEMS FOR ENVIRONMENTAL AND PERSONAL MONITORING - PART 1: GENERAL CHARACTERISTICS AND PERFORMANCE REQUIREMENTS (IEC 62387-1:2007 (MOD))
UNE-EN ISO 4064-2:2015 Water meters for cold potable water and hot water - Part 2: Test methods (ISO 4064-2:2014)
16/30316718 DC : 0 BS EN ISO 80601-2-61 - MEDICAL ELECTRICAL EQUIPMENT - PART 2-61: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF PULSE OXIMETER EQUIPMENT
DIN EN 60546-1:2011-06 CONTROLLERS WITH ANALOGUE SIGNALS FOR USE IN INDUSTRIAL-PROCESS CONTROL SYSTEMS - PART 1: METHODS OF EVALUATING THE PERFORMANCE
EN 62745:2017 Safety of machinery - Requirements for cableless control systems of machinery
CSA E61131.2 :2006 PROGRAMMABLE CONTROLLERS - PART 2: EQUIPMENT REQUIREMENTS AND TESTS
BS EN 60065 : 2014 AUDIO, VIDEO AND SIMILAR ELECTRONIC APPARATUS - SAFETY REQUIREMENTS (IEC 60065:2014, MODIFIED)
BS EN 12405-1 : 2005 GAS METERS - CONVERSION DEVICES - PART 1: VOLUME CONVERSION
CSA E61131.2 : 2006 : R2016 PROGRAMMABLE CONTROLLERS - PART 2: EQUIPMENT REQUIREMENTS AND TESTS
I.S. EN 60068-2-55:2013 ENVIRONMENTAL TESTING - PART 2-55: TESTS - TEST EE AND GUIDANCE - LOOSE CARGO TESTING INCLUDING BOUNCE (IEC 60068-2-55:2013 (EQV))
IEC TS 62735-1:2015 Direct current (DC) plugs and socket-outlets for information and communication technology (ICT) equipment installed in data centres and telecom central offices - Part 1: Plug and socket-outlet system for 2,6 kW
CEI EN 50130-5 : 2012 ALARM SYSTEMS - PART 5: ENVIRONMENTAL TEST METHODS
CEI EN 60539-1 : 2009 DIRECTLY HEATED NEGATIVE TEMPERATURE COEFFICIENT THERMISTORS - PART 1: GENERIC SPECIFICATION
I.S. EN 60601-1-11:2015 MEDICAL ELECTRICAL EQUIPMENT - PART 1-11: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - COLLATERAL STANDARD: REQUIREMENTS FOR MEDICAL ELECTRICAL EQUIPMENT AND MEDICAL ELECTRICAL SYSTEMS USED IN THE HOME HEALTHCARE ENVIRONMENT
CSA C22.2 No. 80601-2-55 : 2014(R2019) MEDICAL ELECTRICAL EQUIPMENT - PART 2-55: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF RESPIRATORY GAS MONITORS
ISO 3930:2000 Instruments for measuring vehicle exhaust emissions
OIML R 144-1 : 2013 INSTRUMENTS FOR CONTINUOUS MEASUREMENT OF CO, NO[X] IN STATIONARY SOURCE EMISSIONS - PART 1: METROLOGICAL AND TECHNICAL REQUIREMENTS
EN 60601-1-11:2015 Medical electrical equipment - Part 1-11: General requirements for basic safety and essential performance - Collateral Standard: Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment
I.S. EN IEC 60728-3:2018 CABLE NETWORKS FOR TELEVISION SIGNALS, SOUND SIGNALS AND INTERACTIVE SERVICES - PART 3: ACTIVE WIDEBAND EQUIPMENT FOR CABLE NETWORKS (TA 5)
I.S. EN 61298-3:2008 PROCESS MEASUREMENT AND CONTROL DEVICES - GENERAL METHODS AND PROCEDURES FOR EVALUATING PERFORMANCE - PART 3: TESTS FOR THE EFFECTS OF INFLUENCE QUANTITIES
ISO 15817:2012 Earth-moving machinery — Safety requirements for remote operator control systems
I.S. EN ISO 16061:2015 INSTRUMENTATION FOR USE IN ASSOCIATION WITH NON-ACTIVE SURGICAL IMPLANTS - GENERAL REQUIREMENTS (ISO 16061:2015)
I.S. EN 60728-14:2014 CABLE NETWORKS FOR TELEVISION SIGNALS, SOUND SIGNALS AND INTERACTIVE SERVICES - PART 14: OPTICAL TRANSMISSION SYSTEMS USING RFOG TECHNOLOGY
I.S. EN 60862-1:2015 SURFACE ACOUSTIC WAVE (SAW) FILTERS OF ASSESSED QUALITY - PART 1: GENERIC SPECIFICATION
I.S. EN 45502-2-3:2010 ACTIVE IMPLANTABLE MEDICAL DEVICES - PART 2-3: PARTICULAR REQUIREMENTS FOR COCHLEAR AND AUDITORY BRAINSTEM IMPLANT SYSTEMS
I.S. EN 62387:2016 RADIATION PROTECTION INSTRUMENTATION - PASSIVE INTEGRATING DOSIMETRY SYSTEMS FOR INDIVIDUAL, WORKPLACE AND ENVIRONMENTAL MONITORING OF PHOTON AND BETA RADIATION
ISO 17966:2016 Assistive products for personal hygiene that support users Requirements and test methods
CSA C22.2 No. 80601-2-61 : 2014(R2019) MEDICAL ELECTRICAL EQUIPMENT - PART 2-61: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF PULSE OXIMETER EQUIPMENT
EN IEC 60728-3:2018 Cable networks for television signals, sound signals and interactive services - Part 3: Active wideband equipment for cable networks (TA 5)
NF EN 60601-2-52 : 2010-06 MEDICAL ELECTRICAL EQUIPMENT - PART 2-52: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF MEDICAL BEDS
IEC TR 60721-4-7:2001+AMD1:2003 CSV Classification of environmental conditions - Part 4-7: Guidance for the correlation and transformation of environmental condition classes of IEC 60721-3 to the environmental tests of IEC 60068 - Portable and non-stationary use
ASTM F 3278 : 2017 Standard Performance Specification for Hand-Held Metal Detectors Used in Safety and Security
I.S. EN 60728-5:2016 CABLE NETWORKS FOR TELEVISION SIGNALS, SOUND SIGNALS AND INTERACTIVE SERVICES - PART 5: HEADEND EQUIPMENT
IEC 60300-3-5:2001 Dependability management - Part 3-5: Application guide - Reliability test conditions and statistical test principles
IEC 60269-3:2010+AMD1:2013 CSV Low-voltage fuses - Part 3: Supplementary requirements for fuses foruse by unskilled persons (fuses mainly for household or similar applications) - Examples of standardized systems of fuses A to F
DIN EN 12405-1:2011-04 GAS METERS - CONVERSION DEVICES - PART 1: VOLUME CONVERSION
18/30364809 DC : DRAFT MAR 2018 BS EN 61535 - INSTALLATION COUPLERS INTENDED FOR PERMANENT CONNECTION IN FIXED INSTALLATIONS
IEC 61514:2000 Industrial-process control systems - Methods of evaluating the performance of valve positioners with pneumatic outputs
IEC 60728-5:2015 Cable networks for television signals, sound signals and interactive services - Part 5: Headend equipment
14/30317823 DC : 0 BS EN 61010-2-201 ED. 2.0 - SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL, AND LABORATORY USE - PART 2-201: PARTICULAR REQUIREMENTS FOR CONTROL EQUIPMENT
IEC 60068-2-55:2013 Environmental testing - Part 2-55: Tests - Test Ee and guidance - Loose cargo testing including bounce
ISO 14630:2012 Non-active surgical implants — General requirements
EN 60512-7-2:2012 Connectors for electronic equipment - Tests and measurements - Part 7-2: Impact tests (free connectors) - Test 7b: Mechanical strength impact
EN ISO 13137:2013 Workplace atmospheres - Pumps for personal sampling of chemical and biological agents - Requirements and test methods (ISO 13137:2013)
EN 60770-3:2014 Transmitters for use in industrial-process control systems - Part 3: Methods for performance evaluation of intelligent transmitters
EN ISO 16061:2015 Instrumentation for use in association with non-active surgical implants - General requirements (ISO 16061:2015)
EN 60846-1:2014 Radiation protection instrumentation - Ambient and/or directional dose equivalent (rate) meters and/or monitors for beta, X and gamma radiation - Part 1: Portable workplace and environmental meters and monitors
EN 61514:2002 Industrial-process control systems - Methods of evaluating the performance of valve positioners with pneumatic outputs
EN 61481-2:2014 Live working - Phase comparators - Part 2: Resistive type to be used for voltages from 1 kV to 36 kV a.c.
EN 80601-2-30:2010/A1:2015 MEDICAL ELECTRICAL EQUIPMENT - PART 2-30: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF AUTOMATED NON-INVASIVE SPHYGMOMANOMETERS (IEC 80601-2-30:2009/A1:2013)
EN 60068-2-55:2013 Environmental testing - Part 2-55: Tests - Test Ee and guidance - Loose cargo testing including bounce
EN 50637:2017 Medical electrical equipment - Particular requirements for the basic safety and essential performance of medical beds for children
EN 60728-6:2011 Cable networks for television signals, sound signals and interactive services - Part 6: Optical equipment
HD 60269-3:2010/A1:2013 LOW-VOLTAGE FUSES - PART 3: SUPPLEMENTARY REQUIREMENTS FOR FUSES FOR USE BY UNSKILLED PERSONS (FUSES MAINLY FOR HOUSEHOLD AND SIMILAR APPLICATIONS) - EXAMPLES OF STANDARDIZED SYSTEMS OF FUSES A TO F
EN 60546-1:2010 Controllers with analogue signals for use in industrial-process control systems - Part 1: Methods of evaluating the performance
EN 12405-3:2015 Gas meters - Conversion devices - Part 3: Flow computer
EN 60728-5:2016 Cable networks for television signals, sound signals and interactive services - Part 5: Headend equipment
EN 62575-1:2016 Radio frequency (RF) bulk acoustic wave (BAW) filters of assessed quality - Part 1: Generic specification
EN 50467:2011 RAILWAY APPLICATIONS - ROLLING STOCK - ELECTRICAL CONNECTORS, REQUIREMENTS AND TEST METHODS
EN 60068-2-27:2009 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
BS 2011-2.1EA(1988) : 1988 AMD 7814 ENVIRONMENTAL TESTING - TEST - TEST EA: SHOCK
CEI EN IEC 61800-5-1:2024 Adjustable speed electrical power drive systems - Part 5-1: Safety requirements - Electrical, thermal and energy
BS 4671(1987) : AMD 7870 METHODS FOR EVALUATING THE PERFORMANCE OF ELECTRICAL AND PNEUMATIC ANALOGUE CHART RECORDERS FOR USE IN INDUSTRIAL PROCESS CONTROL SYSTEMS
BS 2011-2.1ED(1992) : 1992 AMD 7920 ENVIRONMENTAL TESTING - TESTS - FREE FALL
BS 2011-2.1EB(1987) : 1987 AMD 7827 ENVIRONMENTAL TESTING - TEST - TEST EB: BUMP

IEC 60068-2-27:2008 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
IEC GUIDE 104:2010 The preparation of safety publications and the use of basic safety publications and group safety publications
IEC 60068-2-55:2013 Environmental testing - Part 2-55: Tests - Test Ee and guidance - Loose cargo testing including bounce
ISO 48:2010 Rubber, vulcanized or thermoplastic Determination of hardness (hardness between 10 IRHD and 100 IRHD)
ISO 4180-2:1980 Complete, filled transport packages — General rules for the compilation of performance test schedules — Part 2: Quantitative data

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.