EN 61347-1:2015
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
Lamp controlgear - Part 1: General and safety requirements
26-01-2021
15-05-2015
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 General requirements
5 General notes on tests
6 Classification
7 Marking
8 Terminals
9 Earthing
10 Protection against accidental contact with live parts
11 Moisture resistance and insulation
12 Electric strength
13 Thermal endurance test for windings of ballasts
14 Fault conditions
15 Construction
16 Creepage distances and clearances
17 Screws, current-carrying parts and connections
18 Resistance to heat, fire and tracking
19 Resistance to corrosion
20 No-load output voltage
Annex A (normative) - Test to establish whether a
conductive part is a live part which may cause
an electric shock
Annex B (normative) - Particular requirements for
thermally protected lamp controlgear
Annex C (normative) - Particular requirements for
electronic lamp controlgear with means of
protection against overheating
Annex D (normative) - Requirements for carrying out
the heating tests of thermally protected lamp
controlgear
Annex E (normative) - Use of constant S other than
4500 in tw tests
Annex F (normative) - Draught-proof enclosure
Annex G (normative) - Explanation of the derivation of
the values of pulse voltages
Annex H (normative) - Tests
Annex I (normative) - Additional requirements for
built-in magnetic ballasts with double or
reinforced insulation
Annex J (normative) - Schedule of more onerous
requirements
Annex K (informative) - Conformity testing during
manufacture
Annex L (normative) - Particular additional requirements
for controlgears providing SELV
Annex M (informative) - Dielectric strength test voltages
for controlgear intended for the use in impulse
withstand Category III
Annex N (normative) - Requirements for insulation materials
used for double or reinforced insulation
Annex O (normative) - Additional requirements for built-in
electronic controlgear with double
or reinforced insulation
Annex P (normative) - Creepage distances and clearances
and distance through isolation (DTI) for lamp
controlgear which are protected against pollution
by the use of coating or potting
Annex Q (informative) - Example for Up calculation
Annex R (informative) - Concept of creepage distances
and clearances
Annex S (informative) - Examples of controlgear
insulation coordination
Annex T (informative) - Creepage distances and clearances
for controlgear with a higher degree of availability
(impulse withstand category III)
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
NEW! IEC 61347-1:2015 is available as IEC Standards+ 61347-1:2015 which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 61347-1:2015 specifies general and safety requirements for lamp controlgear for use on d.c. supplies up to 250 V and/or a.c. supplies up to 1 000 V at 50 Hz or 60 Hz. This third edition cancels and replaces the second edition published in 2007, Amendment 1:2010 and Amendment 2:2012. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) additional marking requirements;
b) additional requirements for creepage distances and clearances:
- for working voltages with operating frequencies up to 30 kHz;
- for working voltages with higher operating frequencies than 30 kHz;
- for impulse and resonance voltages ignition;
- for basic, supplementary and reinforced insulation;
- for insulation between circuits;
- for coated or potted controlgear;
c) modification of definition of ELV and FELV;
d) modification of schematic drawing, showing the different controlgear classification and insulation requirements;
e) scope extension;
f) new Annex A: test to establish whether a conductive part is a live part which may cause an electric shock;
g) new Annex M: creepage distances and clearances for controlgear where a higher degree of availability (impulse withstand category III) may be requested;
h) new Annex Q: example for Up calculation;
i) new Annex P: creepage distances and clearances and distance through isolation (DTI) for lamp controlgear which are protected against pollution by the use of coating or potting;
j) new Annex R: concept of creepage distances and clearances.
Committee |
CLC/TC 34
|
DevelopmentNote |
Together with the parts 2-1 to 2-9 of EN 61347 supersedes EN 60920, EN 60922, EN 60924, EN 60926, EN 60928 and EN 61046 (05/2001)
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Superseded
|
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.