IEC 60270:2000+AMD1:2015 CSV
Current
The latest, up-to-date edition.
High-voltage test techniques - Partial discharge measurements
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English - French
27-11-2015
IEC 60270:2000+A1:2015 Applies to the measurement of localizedelectrical discharges in insulating media, restricted to only a part of the dielectric under test and only partially bridging the insulation between conductors. The contents of the corrigendum of October 2001 have been included in this copy. This consolidated version consists of the third edition (2000) and its amendment 1 (2015). Therefore, no need to order amendment in addition to this publication.
Committee |
TC 42
|
DevelopmentNote |
Stability Date: 2020. (12/2015)
|
DocumentType |
Standard
|
Pages |
226
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes |
Standards | Relationship |
ONORM OVE EN 60270 : 2016 | Identical |
NF EN 60270 : 2001 AMD 1 2016 | Identical |
NEN EN IEC 60270 : 2001 AMD 1 2016 | Identical |
NEN 10270 : 1983 | Identical |
I.S. EN 60270:2001 | Identical |
PN EN 60270 : 2003 AMD 1 2016 | Identical |
SAC GB/T 7354 : 2003 | Identical |
SN EN 60270:2001+A1:2016 | Identical |
AS 60270-2001 | Identical |
VDE 0110-20 : 1990 | Similar to |
AS 1018-1985 | Identical |
UNE 21313:1985 | Identical |
EN 60270:2001/A1:2016 | Identical |
UTEC 41 300 : 1968 | Similar to |
UNE-EN 60270:2002 | Identical |
BS 4828:1985 | Identical |
NF EN 62199 : 2004 | BUSHINGS FOR D.C. APPLICATION |
BS EN 50482:2008 | Instrument transformers. Three-phase inductive voltage transformers having Um up to 52kV |
10/30239372 DC : DRAFT DEC 2010 | BS EN 60034-27-2 - ROTATING ELECTRICAL MACHINES - PART 27-2: ON-LINE PARTIAL DISCHARGE MEASUREMENTS ON THE STATOR WINDING INSULATION OF ROTATING ELECTRICAL MACHINES |
BS EN 61869-1:2009 | Instrument transformers General requirements |
BS 7640-1(1993) : 1993 AMD 8679 | GUIDE TO HIGH-VOLTAGE TEST TECHNIQUES FOR LOW-VOLTAGE EQUIPMENT - DEFINITIONS, TEST AND PROCEDURE REQUIREMENTS |
BS EN 60076-13:2006 | Power transformers Self-protected liquid-filled transformers |
BS EN 50207:2001 | Railway applications. Electronic power converters for rolling stock |
BS EN 2591-227:2015 | Aerospace series. Elements of electrical and optical connection. Test methods Partial discharges test |
BS EN 60512-4-2:2002 | Connectors for electronic equipment. Tests and measurements. Voltage stress tests Test 4b. Partial discharge |
BS EN 60143-4:2010 | Series capacitors for power systems Thyristors controlled series capacitors |
09/30187488 DC : DRAFT AUG 2009 | BS EN 60076-16 - POWER TRANSFORMERS - PART 16: TRANSFORMERS FOR WIND TURBINES APPLICATION |
I.S. EN 60726:2003 | DRY-TYPE POWER TRANSFORMERS |
CEI EN 60076-11 : 2006 | POWER TRANSFORMERS - PART 11: DRY-TYPE TRANSFORMERS |
07/30173659 DC : 0 | BS EN 62271-200 - HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 200: AC METAL-ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV |
BIS IS 15382-1 : 2014 | INSULATION COORDINATION FOR EQUIPMENT WITHIN LOW-VOLTAGE SYSTEMS - PART 1: PRINCIPLES, REQUIREMENTS AND TESTS |
BS EN 45510-2-7:2002 | Guide for the procurement of power station equipment. Electrical equipment Switchgear and controlgear |
12/30268049 DC : 0 | BS EN 62689-1 - CURRENT AND VOLTAGE SENSORS OR DETECTORS, TO BE USED FOR FAULT PASSAGE INDICATION PURPOSES - PART 1: GENERAL PRINCIPLES AND REQUIREMENTS |
07/30158043 DC : 0 | BS EN 62501 - ELECTRICAL TESTING OF VOLTAGE SOURCE CONVERTER (VSC) VALVES FOR HIGH-VOLTAGE DIRECT CURRENT (HVDC) POWER TRANSMISSION |
97/208495 DC : DRAFT JUL 1997 | IEC 61640 - HV GAS-INSULATED TRANSMISSION LINES FOR RATED VOLTAGES OF 72,5 KV AND ABOVE |
I.S. EN 62068:2013 | ELECTRICAL INSULATING MATERIALS AND SYSTEMS - GENERAL METHOD OF EVALUATION OF ELECTRICAL ENDURANCE UNDER REPETITIVE VOLTAGE IMPULSES (IEC 62068:2013 (EQV)) |
BS EN 60214-1:2014 | Tap-changers Performance requirements and test methods |
11/30235280 DC : 0 | BS EN 50152-1 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 1: CIRCUIT-BREAKERS WITH NOMINAL VOLTAGE ABOVE 1 KV |
BS IEC/IEEE 65700-19-03 : 2014 | BUSHINGS FOR DC APPLICATION |
CEI EN 62271-204 : 2012 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 204: RIGID GAS-INSULATED TRANSMISSION LINES FOR RATED VOLTAGES ABOVE 52 KV |
11/30247685 DC : 0 | BS EN 65700-19-03 - BUSHINGS FOR DC APPLICATION |
BS EN 61287-1:2014 | Railway applications. Power converters installed on board rolling stock Characteristics and test methods |
CSA C88.1 : 1996 : R2015 | POWER TRANSFORMERS AND REACTOR BUSHINGS |
02/211632 DC : DRAFT DEC 2002 | IEC 69747-5-4 ED.1 - SEMICONDUCTOR DEVICES - DISCRETE DEVICES - PART 5-4: OPTOELECTRONIC DEVICES - SEMICONDUCTOR LASERS |
BS EN 60885-2:2003 | Electrical test methods for electric cables Partial discharge tests |
BS IEC 60747-5-4:2006 | Semiconductor devices. Discrete devices Optoelectronic devices. Semiconductor lasers |
I.S. EN 60885-3:2015 | ELECTRICAL TEST METHODS FOR ELECTRIC CABLES - PART 3: TEST METHODS FOR PARTIAL DISCHARGE MEASUREMENTS ON LENGTHS OF EXTRUDED POWER CABLES |
98/202856 DC : 0 | PREN 60044-1 - INSTRUMENT TRANSFORMERS - PART 1: CURRENT TRANSFORMERS |
CSA C60044-5:2007 | INSTRUMENT TRANSFORMERS - PART 5: CAPACITOR VOLTAGE TRANSFORMERS |
BS EN 62271-203:2012 | High-voltage switchgear and controlgear Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV |
BS EN 60076-6:2008 | Power transformers Reactors |
I.S. EN 60143-4:2010 | SERIES CAPACITORS FOR POWER SYSTEMS - PART 4: THYRISTOR CONTROLLED SERIES CAPACITORS |
BS EN 61442:2005 | Test methods for accessories for power cables with rated voltages from 6 kV (Um = 7,2 kV) up to 36 kV (Um = 42 kV) |
CSA C60044-5 : 2007 : R2011 | INSTRUMENT TRANSFORMERS - PART 5: CAPACITOR VOLTAGE TRANSFORMERS |
CEI EN 60885-2 : 2006 | ELECTRICAL TEST METHODS FOR ELECTRIC CABLES - PART 2: PARTIAL DISCHARGE TESTS |
PREN 50152-3-2 : DRAFT 2015 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR A.C. SWITCHGEAR - PART 3-2: MEASUREMENT, CONTROL AND PROTECTION DEVICES FOR SPECIFIC USE IN A.C. TRACTION SYSTEMS - SINGLE-PHASE CURRENT TRANSFORMERS |
NF EN 60143-4 : 2011 | SERIES CAPACITORS FOR POWER SYSTEMS - PART 4: THYRISTOR CONTROLLED SERIES CAPACITORS |
I.S. EN 60244-1:2000 | METHODS OF MEASUREMENT FOR RADIO TRANSMITTERS - PART 1: GENERAL CHARACTERISTICS FOR BROADCAST TRANSMITTERS |
EN IEC 60099-8:2018 | Surge arresters - Part 8: Metal-oxide surge arresters with external series gap (EGLA) for overhead transmission and distribution lines of a.c. systems above 1 kV |
CSA C60044-8 : 2007 : R2016 | INSTRUMENT TRANSFORMERS - PART 8: ELECTRONIC CURRENT TRANSFORMERS |
IEEE C37.122.1-2014 | IEEE Guide for Gas-Insulated Substations Rated Above 52 kV |
CEI EN 60747-15 : 2012 | SEMICONDUCTOR DEVICES - DISCRETE DEVICES - PART 15: ISOLATED POWER SEMICONDUCTOR DEVICES |
CEI EN 50526-1 : 2013 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SURGE ARRESTERS AND VOLTAGE LIMITING DEVICES - PART 1: SURGE ARRESTERS |
I.S. EN 60694:1999 | COMMON SPECIFICATIONS FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS |
CEI EN 61378-2 : 2002 | CONVERTOR TRANSFORMERS - PART 2: TRANSFORMERS FOR HVDC APPLICATIONS |
I.S. EN 60076-11:2004 | POWER TRANSFORMERS - PART 11: DRY-TYPE TRANSFORMERS |
I.S. EN 60076-16:2011 | POWER TRANSFORMERS - PART 16: TRANSFORMERS FOR WIND TURBINES APPLICATIONS (IEC 60076-16:2011) |
I.S. EN 3197:2010 | AEROSPACE SERIES - DESIGN AND INSTALLATION OF AIRCRAFT ELECTRICAL AND OPTICAL INTERCONNECTION SYSTEMS |
EN 62271-1:2017 | High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear |
CEI EN 62199 : 2005 | BUSHINGS FOR D.C. APPLICATION |
UNE-EN 60099-4:2016 | Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems |
CSA C61869-1 : 2014 | INSTRUMENT TRANSFORMERS - PART 1: GENERAL REQUIREMENTS |
CEI EN 60244-1 : 2000 | METHODS OF MEASUREMENT FOR RADIO TRANSMITTERS - PART 1: GENERAL CHARACTERISTICS FOR BROADCAST TRANSMITTERS |
I.S. EN 50152-3-3:2016 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR A.C. SWITCHGEAR - PART 3-3: MEASUREMENT, CONTROL AND PROTECTION DEVICES FOR SPECIFIC USE IN A.C. TRACTION SYSTEMS - VOLTAGE TRANSFORMERS |
UNE-EN 61287-1:2015 | Railway applications - Power converters installed on board rolling stock - Part 1: Characteristics and test methods |
NF EN 60076-13 : 2007 | POWER TRANSFORMERS - PART 13: SELF-PROTECTED LIQUID-FILLED TRANSFORMERS |
IEC 61010-031:2015 RLV | Safety requirements for electrical equipment for measurement, control and laboratory use - Part 031: Safety requirements for hand-held probe assemblies for electrical measurement and test |
IEC 60143-1:2015 | Series capacitors for power systems - Part 1: General |
UNE-EN 62271-203:2013 | High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV |
IEC 60694:1996+AMD1:2000+AMD2:2001 CSV | Common specifications for high-voltage switchgear and controlgear standards |
EN 60099-4:2014 | Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems |
EN 60885-2:2003 | Electrical test methods for electric cables - Part 2: Partial discharge tests |
EN 60694:1996/A2:2001 | COMMON SPECIFICATIONS FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS |
EN 60214:1997 | On-load tap-changers |
EN 60747-15:2012 | Semiconductor devices - Discrete devices - Part 15: Isolated power semiconductor devices |
EN 61442:2005 | Test methods for accessories for power cables with rated voltages from 6 kV (Um = 7,2 kV) up to 36 kV (Um = 42 kV) |
EN 60076-11:2004 | Power transformers - Part 11: Dry-type transformers |
EN 62271-201:2014 | High-voltage switchgear and controlgear - Part 201: AC solid-insulation enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV |
HD 597 S1:1992/corrigendum:1992 | COUPLING CAPACITORS AND CAPACITOR DIVIDERS |
EN 60505:2011/AC:2017-03 | EVALUATION AND QUALIFICATION OF ELECTRICAL INSULATION SYSTEMS (IEC 60505:2011/COR1:2017) |
EN 60660:1999 | Insulators - Tests on indoor post insulators of organic material for systems with nominal voltages greater than 1 kV up to but not including 300 kV |
EN 50152-3-3:2016 | Railway applications - Fixed installations - Particular requirements for a.c. switchgear - Part 3-3: Measurement, control and protection devices for specific use in a.c. traction systems - Voltage transformers |
EN 60747-5-3:2001/A1:2002 | DISCRETE SEMICONDUCTOR DEVICES AND INTEGRATED CIRCUITS - PART 5-3: OPTOELECTRONIC DEVICES - MEASURING METHODS |
EN 60143-1:2015/AC:2017-05 | Series capacitors for power systems - Part 1: General |
EN 62199:2004 | Bushings for d.c. application |
EN 60298:1996/A11:1999 | A.C. METAL-ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV |
EN 60265-2:1993/A2:1998 | HIGH-VOLTAGE SWITCHES - HIGH-VOLTAGE SWITCHES FOR RATED VOLTAGES OF 52 KV AND ABOVE |
EN 50482:2008 | Instrument transformers - Three-phase inductive voltage transformers having Um up to 52 kV |
EN 60044-5:2004 | Instrument transformers - Part 5: Capacitor voltage transformers |
EN 60060-2:2011 | High-voltage test techniques - Part 2: Measuring systems |
EN 50152-3-2:2016 | Railway applications - Fixed installations - Particular requirements for a.c. switchgear - Part 3-2: Measurement, control and protection devices for specific use in a.c. traction systems - Current transformers |
EN 60726:2003 | Dry-type power transformers |
EN 50207:2000 | Railway applications - Electronic power converters for rolling stock |
BS IEC TS 60034-18.34 : 2000 AMD 16621 | ROTATING ELECTRICAL MACHINES - PART 18-34: FUNCTIONAL EVALUATION OF INSULATION SYSTEMS - TEST PROCEDURES FOR FORM-WOUND WINDINGS - EVALUATION OF THERMOMECHANICAL ENDURANCE OF INSULATION SYSTEMS |
09/30200407 DC : 0 | BS EN 50526-1 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SURGE ARRESTERS AND VOLTAGE LIMITING DEVICES - PART 1: SURGE ARRESTERS |
09/30176337 DC : 0 | BS EN 61954 - POWER ELECTRONICS FOR ELECTRICAL TRANSMISSION AND DISTRIBUTION SYSTEMS - TESTING OF THYRISTOR VALVES FOR STATIC VAR COMPENSATORS |
BS EN 50152-1 : 2012 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 1: CIRCUIT-BREAKERS WITH NOMINAL VOLTAGE ABOVE 1 KV |
BS EN 3197:2010 | Aerospace series. Design and installation of aircraft electrical and optical interconnection systems |
06/30149569 DC : DRAFT APR 2006 | IEC 60060-1 - HIGH-VOLTAGE TEST TECHNIQUES - PART 1: GENERAL DEFINITIONS AND TEST REQUIREMENTS |
DD CLC/TS 60034-18-34:2004 | Rotating electrical machines. Functional evaluation of insulation systems Test procedures for form-wound windings. Evaluation of thermomechanical endurance of insulation systems |
I.S. EN 50482:2008 | INSTRUMENT TRANSFORMERS - THREE-PHASE INDUCTIVE VOLTAGE TRANSFORMERS HAVING U[M] UP TO 52 KV |
14/30284930 DC : 0 | BS EN 62689-2 ED 1.0 - CURRENT AND VOLTAGE SENSORS OR DETECTORS TO BE USED FOR FAULT PASSAGE INDICATION PURPOSES - PART 2: GENERAL PRINCIPLES AND REQUIREMENTS |
UNE-EN 62271-204:2012 | High-voltage switchgear and controlgear - Part 204: Rigid gas-insulated transmission lines for rated voltage above 52 kV |
UNE-EN 50152-2:2013 | Railway applications - Fixed installations - Particular requirements for alternating current switchgear - Part 2: Disconnectors, earthing switches and switches with nominal voltage above 1 kV |
BS EN 60358-1:2012 | Coupling capacitors and capacitor dividers General rules |
16/30336914 DC : 0 | BS EN 60076-57-129 ED 1.0 - CONVERTOR TRANSFORMERS - PART 57-129: TRANSFORMERS FOR HVDC APPLICATIONS |
03/112421 DC : DRAFT NOV 2003 | IEC 60034-18-41 TS ED.1 - ROTATING ELECTRICAL MACHINES - PART 18-41: EVALUATION AND QUALIFICATION OF ELECTRICAL INSULATION SYSTEMS USED IN ROTATING ELECTRICAL MACHINES WHEN FED FROM VOLTAGE CONVERTERS |
BS EN 60044-1:1999 | Instrument transformers Current transformers |
BS EN 60044-5:2004 | Instrument transformers Capacitor voltage transformers |
17/30331680 DC : 0 | BS ISO 18095 - CONDITION MONITORING AND DIAGNOSTICS OF POWER TRANSFORMERS |
NF EN 61869-1 : 2009 | INSTRUMENT TRANSFORMERS - PART 1: GENERAL REQUIREMENTS |
12/30253687 DC : DRAFT JUNE 2012 | BS EN 62478 - HIGH VOLTAGE TEST TECHNIQUES - MEASUREMENT OF PARTIAL DISCHARGES BY ELECTROMAGNETIC AND ACOUSTIC METHODS |
NF EN 60343 : 1993 | RECOMMENDED TEST METHODS FOR DETERMINING THE RELATIVE RESISTANCE OF INSULATING MATERIALS TO BREAKDOWN BY SURFACE DISCHARGES |
CEI EN 60660 : 2000 | INSULATORS TESTS ON INDOOR POST INSULATORS OF ORGANIC MATERIAL FOR SYSTEMS WITH NOMINAL VOLTAGES GREATER THAN 1 KV UP TO BUT NOT INCLUDING 300 KV |
CEI EN 60664-4 : 2006 | INSULATION COORDINATION FOR EQUIPMENT WITHIN LOW-VOLTAGE SYSTEMS - PART 4: CONSIDERATION OF HIGH-FREQUENCY VOLTAGE STRESS |
BS EN 60660:2000 | Insulators. Tests on indoor post insulators of organic material for systems with nominal voltages greater than 1 kV up to but not including 300 kV |
BS EN 62068-1:2003 | Electrical insulation systems. Electrical stresses produced by repetitive impulses General method of evaluation of electrical endurance |
13/30269681 DC : 0 | BS EN 62823 - THYRISTOR VALVES FOR THYRISTOR CONTROLLED SERIES CAPACITORS (TCSC) - ELECTRICAL TESTING |
DIN EN 61954 : 2018 | STATIC VAR COMPENSATORS (SVC) - TESTING OF THYRISTOR VALVES (IEC 61954:2011 + A1:2013 + A2:2017) |
CEI EN 60076-3 : 2015 | POWER TRANSFORMERS - PART 3: INSULATION LEVELS, DIELECTRIC TESTS AND EXTERNAL CLEARANCES IN AIR |
03/100554 DC : DRAFT APR 2003 | IEC 60060-3 ED.1 - HIGH VOLTAGE TEST TECHNIQUES - PART 3: DEFINITIONS AND REQUIREMENTS FOR ON-SITE TESTS |
BS EN 60060-2:1995 | High-voltage test techniques Measuring systems |
BS EN 60664-1:2007 | Insulation coordination for equipment within low-voltage systems Principles, requirements and tests |
BS EN 50526-1:2012 | Railway applications. Fixed Installations. D.C. surge arresters and voltage limiting devices Surge arresters |
UNI CEI EN 45510-2-5 : 2011 | GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-5: ELECTRICAL EQUIPMENT - MOTORS |
16/30334804 DC : 0 | BS EN 62501:2009+A2 - VOLTAGE SOURCED CONVERTER (VSC) VALVES FOR HIGH-VOLTAGE DIRECT CURRENT (HVDC) POWER TRANSMISSION - ELECTRICAL TESTING |
BS EN 60747-5-5 : 2011 | SEMICONDUCTOR DEVICES - DISCRETE DEVICES - PART 5-5: OPTOELECTRONIC DEVICES - PHOTOCOUPLERS |
VDE 0303-70 : 1994 | METHODS OF TEST FOR INSULATING MATERIALS FOR ELECTRICAL PURPOSES; BREAKDOWN BY SURFACE DISCHARGES, TEST METHODS |
CSA C60044-7 : 2007 : R2016 | INSTRUMENT TRANSFORMERS - PART 7: ELECTRONIC VOLTAGE TRANSFORMERS |
BS EN 62199:2004 | Bushings for D.C. application |
09/30167595 DC : 0 | BS EN 60099-8 ED.1 - SURGE ARRESTERS - PART 8: METAL-OXIDE SURGE ARRESTERS WITH EXTERNAL SERIES GAP (EGLA) FOR OVERHEAD TRANSMISSION AND DISTRIBUTION LINES OF A.C. SYSTEMS ABOVE 1 KV |
04/30112722 DC : DRAFT APR 2004 | IEC 60044-5 ED.1 - INSTRUMENT TRANSFORMERS - PART 5: CAPACITOR VOLTAGE TRANSFORMERS |
I.S. EN 60747-15:2012 | SEMICONDUCTOR DEVICES - DISCRETE DEVICES - PART 15: ISOLATED POWER SEMICONDUCTOR DEVICES (IEC 60747-15:2010 (EQV)) |
CEI EN 60664-1 : 2008 | INSULATION COORDINATION FOR EQUIPMENT WITHIN LOW-VOLTAGE SYSTEMS - PART 1: PRINCIPLES, REQUIREMENTS AND TESTS |
09/30205410 DC : 0 | BS EN 62271-204 - HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 204: RIGID HIGH-VOLTAGE, GAS-INSULATED TRANSMISSION LINES FOR RATED VOLTAGES OF 72,5 KV AND ABOVE |
CEI UNI EN 45510-2-7 : 2006 | GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-7: ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR |
04/30111859 DC : 0 | IEC 62271-1 - HIGH-VOLTAGE SWITCHGEAR AND CONTROL GEAR - PART 1: COMMON SPECIFICATIONS |
CEI EN 62689-1 : 1ED 2017 | CURRENT AND VOLTAGE SENSORS OR DETECTORS, TO BE USED FOR FAULT PASSAGE INDICATION PURPOSES - PART 1: GENERAL PRINCIPLES AND REQUIREMENTS |
BS EN 45510-2-5:2002 | Guide for the procurement of power station equipment. Electrical equipment Motors |
08/30179134 DC : DRAFT MAR 2008 | BS EN 60143-4 - SERIES CAPACITORS FOR POWER SYSTEMS - PART 4: THYRISTOR CONTROLLED SERIES CAPACITORS |
DD IEC PAS 60044-5 : DRAFT SEP 2002 | INSTRUMENT TRANSFORMERS - PART 5: CAPACITOR VOLTAGE TRANSFORMERS |
CEI EN 60076-16 : 2012 | POWER TRANSFORMERS - PART 16: TRANSFORMERS FOR WIND TURBINES APPLICATIONS |
CSA C22.2 No. 242 : 92(R2005) | IEEE STANDARD TEST PROCEDURES AND REQUIREMENTS FOR HIGH-VOLTAGE ALTERNATING-CURRENT CABLE TERMINATIONS |
CSA C60044-2 : 2007 : R2011 | INSTRUMENT TRANSFORMERS - PART 2: INDUCTIVE VOLTAGE TRANSFORMERS |
EN 60343:1992 | Recommended test methods for determining the relative resistance of insulating materials to breakdown by surface discharges |
NF EN 60060-1 : 2011 | HIGH-VOLTAGE TEST TECHNIQUES - PART 1: GENERAL DEFINITIONS AND TEST REQUIREMENTS |
CSA C60044-8 : 2007 : R2011 | INSTRUMENT TRANSFORMERS - PART 8: ELECTRONIC CURRENT TRANSFORMERS |
BS EN 60310:2016 | Railway applications. Traction transformers and inductors on board rolling stock |
IEEE C37.100.1-2007 | IEEE Standard of Common Requirements for High Voltage Power Switchgear Rated Above 1000 V |
BS EN 60044-8:2002 | Instrument transformers Electronic current transformers |
I.S. EN 60885-2:2003 | ELECTRICAL TEST METHODS FOR ELECTRIC CABLES - PART 2: PARTIAL DISCHARGE TESTS |
I.S. EN 62146-1:2014 | GRADING CAPACITORS FOR HIGH-VOLTAGE ALTERNATING CURRENT CIRCUIT-BREAKERS - PART 1: GENERAL |
I.S. EN 60505:2011 | EVALUATION AND QUALIFICATION OF ELECTRICAL INSULATION SYSTEMS |
SAE AIR 6127 : 2017 | MANAGING HIGHER VOLTAGES IN AEROSPACE ELECTRICAL SYSTEMS |
I.S. EN 60076-13:2006 | POWER TRANSFORMERS - PART 13: SELF-PROTECTED LIQUID-FILLED TRANSFORMERS |
IEC 60137:2017 | Insulated bushings for alternating voltages above 1000 V |
BS EN 60137:2017 | Insulated bushings for alternating voltages above 1000 V |
I.S. EN 61287-1:2014 | RAILWAY APPLICATIONS - POWER CONVERTERS INSTALLED ON BOARD ROLLING STOCK - PART 1: CHARACTERISTICS AND TEST METHODS |
I.S. HD 632:2016 | POWER CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES ABOVE 36 KV (U[M] = 42 KV) UP TO 150 KV (U[M] = 170 KV) |
I.S. EN 61007:1998 | TRANSFORMERS AND INDUCTORS FOR USE IN ELECTRONIC AND TELECOMMUNICATION EQUIPMENT - MEASURING METHODS AND TEST PROCEDURES |
I.S. EN 60358-1:2012 | COUPLING CAPACITORS AND CAPACITOR DIVIDERS - PART 1: GENERAL RULES (IEC 60358-1:2012 (EQV)) |
BS EN 61010-031:2015 | Safety requirements for electrical equipment for measurement, control and laboratory use Safety requirements for hand-held probe assemblies for electrical measurement and test |
I.S. EN 61442:2005 | TEST METHODS FOR ACCESSORIES FOR POWER CABLES WITH RATED VOLTAGES FROM 6 KV (U[M] = 7,2 KV) UP TO 36 KV (U[M] = 42 KV) |
IEC 60099-8:2017 | Surge arresters - Part 8: Metal-oxide surge arresters with external series gap (EGLA) for overhead transmission and distribution lines of a.c. systems above 1 kV |
IEC 62505-2:2016 | Railway applications - Fixed installations - Particular requirements for AC switchgear - Part 2: Disconnectors, earthing switches and switches with nominal voltage above 1 kV |
CEI EN 62271-201 : 2015 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 201: AC SOLID-INSULATION ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV |
VDE 0553-100 : 2018 | STATIC VAR COMPENSATORS (SVC) - TESTING OF THYRISTOR VALVES (IEC 61954:2011 + A1:2013 + A2:2017) |
CEI EN 60099-4 : 2015 | SURGE ARRESTERS - PART 4: METAL-OXIDE SURGE ARRESTERS WITHOUT GAPS FOR A.C. SYSTEMS |
NF EN 60076-6 : 2008 | POWER TRANSFORMERS - PART 6: REACTORS |
UNE-EN 50299-2:2015 | Oil-immersed cable connection assemblies for transformers and reactors having highest voltage for equipment Um from 72,5 kV to 550 kV - Part 2: Dry-type cable terminations |
CEI EN 60143-4 : 2012 | SERIES CAPACITORS FOR POWER SYSTEMS - PART 4: THYRISTOR CONTROLLED SERIES CAPACITORS |
I.S. EN 61204-7:2006 | LOW VOLTAGE POWER SUPPLIES, D.C. OUTPUT - PART 7: SAFETY REQUIREMENTS |
I.S. EN 60099-4:2014 | SURGE ARRESTERS - PART 4: METAL-OXIDE SURGE ARRESTERS WITHOUT GAPS FOR A.C. SYSTEMS |
IEC 62271-111:2012 | High-voltage switchgear and controlgear - Part 111: Automatic circuit reclosers and fault interrupters for alternating current systems up to 38 kV |
IEC 62271-1:2017 | High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear |
I.S. EN 60664-4:2006 | INSULATION COORDINATION FOR EQUIPMENT WITHIN LOW-VOLTAGE SYSTEMS - PART 4: CONSIDERATION OF HIGH-FREQUENCY VOLTAGE STRESS |
IEC/IEEE 65700-19-03:2014 | Bushings for DC application |
IEC TS 60034-18-34:2000 | Rotating electrical machines - Part 18-34: Functional evaluation of insulation systems - Test procedures for form-wound windings - Evaluation of thermomechanical endurance of insulation systems |
I.S. EN 61954:2011 | STATIC VAR COMPENSATORS (SVC) - TESTING OF THYRISTOR VALVES |
IEC 62689-1:2016 | Current and voltage sensors or detectors, to be used for fault passage indication purposes - Part 1: General principles and requirements |
IEC 60099-6:2002 | Surge arresters - Part 6: Surge arresters containing both series and parallel gapped structures - Rated 52 kV and less |
UNE-EN 62271-200:2012 | High-voltage switchgear and controlgear - Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV |
IEC 60060-2:2010 | High-voltage test techniques - Part 2: Measuring systems |
IEC 60664-4:2005 | Insulation coordination for equipment within low-voltage systems - Part 4: Consideration of high-frequency voltage stress |
IEC 60660:1999 | Insulators - Tests on indoor post insulators of organic material for systems with nominal voltages greater than 1 000 V up to but not including 300 kV |
IEC 60044-1:1996+AMD1:2000+AMD2:2002 CSV | Instrument transformers - Part 1: Current transformers |
IEC 60747-5-3:1997+AMD1:2002 CSV | Discrete semiconductor devices and integrated circuits - Part 5-3: Optoelectronic devices - Measuring methods |
IEC 60137:2017 RLV | Insulated bushings for alternating voltages above 1000 V |
ISA 61010-031 : 2007 | SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL, AND LABORATORY USE - PART 031: SAFETY REQUIREMENTS FOR HAND-HELD PROBE ASSEMBLIES FOR ELECTRICAL MEASUREMENT AND TEST |
IEC 60700-1:2015 RLV | Thyristor valves for high voltage direct current (HVDC) power transmission - Part 1: Electrical testing |
VDE 0380-5 : 1995 | INSULATING LIQUIDS - DETERMINATION OF THE PARTIAL DISCHARGE INCEPTION VOLTAGE (PDIV) - TEST METHODS |
VDE 0884 : 1987 | OPTOCOUPLER FOR PROTECTIVE SEPARATION AGAINST ELECTRIC SHOCK, REQUIREMENTS, TESTS |
BS 4571:1994 | On-load tap-changers |
BS 5227:1992 | Specification for a.c. metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV |
BS 6581:1995 | Common clauses for high-voltage switchgear and controlgear standards |
VDE 0414-2 : 99 AMD 1 2001 | INSTRUMENT TRANSFORMERS - PART 1: INDUCTIVE VOLTAGE TRANSFORMERS |
VDE 0532-42 : 2001 | CONVERTOR TRANSFORMERS - PART 2: TRANSFORMERS FOR HVDC APPLICATIONS |
VDE 0414-44-7 : 2000 | INSTRUMENT TRANSFORMERS - PART 7: ELECTRONIC VOLTAGE TRANSFORMERS |
DIN VDE 0380-5 : 1995 | INSULATING LIQUIDS - DETERMINATION OF THE PARTIAL DISCHARGE INCEPTION VOLTAGE (PDIV) - TEST METHODS |
DIN EN 60044-7 : 2000 | INSTRUMENT TRANSFORMERS - PART 7: ELECTRONIC VOLTAGE TRANSFORMERS |
BS 6493-1.5:1992 | Semiconductor devices. Discrete devices Recommendations for optoelectronic devices - Section 5: Recommendations for optoelectronic devices |
DIN VDE 0110-20 : 1990 | INSULATION CO-ORDINATION FOR EQUIPMENT WITHIN LOW-VOLTAGES SYSTEMS; PARTIAL DISCHARGE TESTS; APPLICATION GUIDE |
VDE 0805 : 2001 | SAFETY OF INFORMATION TECHNOLOGY EQUIPMENT |
DIN EN 60660 : 2000 | INSULATORS - TESTS ON INDOOR POST INSULATORS OF ORGANIC MATERIAL FOR SYSTEMS WITH NOMINAL VOLTAGES GREATER THAN 1 KV UP TO BUT NOT INCLUDING 300 KV |
VDE 0804 : 1989 AMD 1 1992 | TELECOMMUNICATIONS; ADDITIONAL REQUIREMENTS FOR CONSTRUCTION AND TESTING OF APPARATUS |
IEEE PC57.19.00/D4:2022 | IEEE Draft Standard General Requirements and Test Procedure for Power Apparatus Bushings |
12/30253935 DC : DRAFT JUNE 2012 | BS EN 62271-201 - HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - AC SOLID-INSULATED ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV |
CEI EN 62068 : 2014 | ELECTRICAL INSULATING MATERIALS AND SYSTEMS - GENERAL METHOD OF EVALUATION OF ELECTRICAL ENDURANCE UNDER REPETITIVE VOLTAGE IMPULSES |
IEEE 4-2013 | IEEE Standard for High-Voltage Testing Techniques |
BS EN 60044-2:1999 | Instrument transformers Inductive voltage transformers |
IEEE/IEC C37.60-2012 | IEEE/IEC International Standard - High-voltage switchgear and controlgear - Part 111: Automatic circuit reclosers and fault interrupters for alternating current systems up to 38 kV |
17/30356577 DC : 0 | BS EN 60099-8 - SURGE ARRESTERS - PART 8: METAL-OXIDE SURGE ARRESTERS WITH EXTERNAL SERIES GAP (EGLA) FOR OVERHEAD TRANSMISSION AND DISTRIBUTION LINES OF A.C. SYSTEMS ABOVE 1 KV |
13/30273350 DC : 0 | BS EN 60700-1 - THYRISTOR VALVES FOR HIGH VOLTAGE DIRECT CURRENT (HVDC) POWER TRANSMISSION - PART 1: ELECTRICAL TESTING |
BS EN 61850-7-4:2010 | Communication networks and systems for power utility automation Basic communication structure. Compatible logical node classes and data object classes |
07/30162213 DC : 0 | BS EN 60747-15 - SEMICONDUCTOR DEVICES - DISCRETE DEVICES - PART 15: ISOLATED POWER SEMICONDUCTOR DEVICES |
13/30264553 DC : 0 | BS EN 61287-1 ED 3.0 - RAILWAY APPLICATIONS - POWER CONVERTORS INSTALLED ON BOARD ROLLING STOCK - PART 1: CHARACTERISTICS AND TEST METHODS |
BS EN 62068:2013 | Electrical insulating materials and systems. General method of evaluation of electrical endurance under repetitive voltage impulses |
IEEE C57.19.00 : 2004 | GENERAL REQUIREMENTS AND TEST PROCEDURE FOR POWER APPARATUS BUSHINGS |
14/30310457 DC : 0 | BS EN 60143-1 - SERIES CAPACITORS FOR POWER SYSTEMS - PART 1: GENERAL |
CEI EN 60044-7 : 2001 | INSTRUMENT TRANSFORMERS - PART 7: ELECTRONIC VOLTAGE TRANSFORMERS |
12/30235047 DC : 0 | BS EN 62146-1 ED.1 - GRADING CAPACITORS FOR HIGH-VOLTAGE ALTERNATING CURRENT CIRCUIT-BREAKERS |
13/30293130 DC : 0 | BS EN 62271-104:2009 AMD 1 - HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 104: ALTERNATING CURRENT SWITCHES FOR RATED VOLTAGES HIGHER THAN 52 KV |
08/30184557 DC : DRAFT JUNE 2008 | BS EN 62271-111 - HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 111: PAD-MOUNTED, DRY VAULT, AND SUBMERSIBLE AUTOMATIC CIRCUIT RECLOSERS AND FAULT INTERRUPTERS FOR ALTERNATING CURRENT SYSTEMS UP TO 38 KV |
13/30265253 DC : 0 | BS EN 60214-1 ED 2 - TAP-CHANGERS - PART 1: PERFORMANCE REQUIREMENTS AND TEST METHODS |
14/30318963 DC : DRAFT DEC 2014 | BS EN 61057 - LIVE WORKING - INSULATING AERIAL DEVICES FOR MOUNTING ON A CHASSIS |
I.S. EN 60076-1:2011 | POWER TRANSFORMERS - PART 1: GENERAL (IEC 60076-1:2011) |
15/30314795 DC : 0 | BS EN 50152-3-3 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR A.C. SWITCHGEAR - PART 3-3: MEASUREMENT, CONTROL AND PROTECTION DEVICES FOR SPECIFIC USE IN A.C. TRACTION SYSTEMS - SINGLE-PHASE INDUCTIVE VOLTAGE TRANSFORMERS |
PREN 50152-3-3 : DRAFT 2015 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR A.C. SWITCHGEAR - PART 3-3: MEASUREMENT, CONTROL AND PROTECTION DEVICES FOR SPECIFIC USE IN A.C. TRACTION SYSTEMS - SINGLE-PHASE INDUCTIVE VOLTAGE TRANSFORMERS |
UNE-EN 60137:2011 | Insulated bushings for alternating voltages above 1 000 V |
12/30243450 DC : DRAFT FEB 2012 | BS ISO 20958-1 - CONDITION MONITORING AND DIAGNOSTICS OF MACHINES - ELECTRICAL SIGNATURE ANALYSIS - PART 1: THREE-PHASE INDUCTION MOTORS |
BS EN 60099-8:2011 | Surge arresters Metal-oxide surge arresters with external series gap (EGLA) for overhead transmission and distribution lines of a.c. systems above 1 kV |
DD IEC/TS 61934:2011 | Electrical insulating materials and systems. Electrical measurement of partial discharges (PD) under short rise time and repetitive voltage impulses |
BS EN 50299-2:2014 | Oil-immersed cable connection assemblies for transformers and reactors having highest voltage for equipment Um from 72,5 kV to 550 kV Dry-type cable terminations |
02/210393 DC : DRAFT JUNE 2003 | EN 60885-2 - ELECTRICAL TEST METHODS FOR ELECTRIC CABLES - PART 2: PARTIAL DISCHARGE TESTS |
I.S. EN 60143-2:2013 | SERIES CAPACITORS FOR POWER SYSTEMS - PART 2: PROTECTIVE EQUIPMENT FOR SERIES CAPACITOR BANKS (IEC 60143-2:2012 (EQV)) |
BS EN 60214:1998 | On-load tap-changers |
BS EN 60076-16:2011 | Power transformers Transformers for wind turbines applications |
NF EN 60044-1 : 2000 AMD 2 2003 | INSTRUMENT TRANSFORMERS - PART 1: CURRENT TRANSFORMERS |
BS 5772-2:1979 | Specification for electromechanical components for electronic equipment: basic testing procedures and measuring methods General examination, electrical continuity and contact resistance tests, insulation tests and voltage stress tests |
IEEE 1861-2014 | IEEE Guide for On-Site Acceptance Tests of Electrical Equipment and System Commissioning of 1000 kV AC and Above |
NF EN 60664-1 : 2007 | INSULATION COORDINATION FOR EQUIPMENT WITHIN LOW-VOLTAGE SYSTEMS - PART 1: PRINCIPLES, REQUIREMENTS AND TESTS |
IEEE 400-2012 REDLINE | IEEE Guide for Field Testing and Evaluation of the Insulation of Shielded Power Cable Systems Rated 5 kV and Above |
02/210392 DC : DRAFT JUNE 2002 | EN 60885-3 - ELECTRICAL TEST METHODS FOR ELECTRIC CABLES - PART 3: TEST METHODS FOR PARTIAL DISCHARGE MEASUREMENTS ON LENGTHS OF EXTRUDED POWER CABLES |
14/30271248 DC : 0 | BS EN 60310 ED 4.0 - RAILWAY APPLICATIONS - TRACTION TRANSFORMERS AND INDUCTORS ON BOARD ROLLING STOCK |
BS EN 120000:1996 | Harmonized system of quality assessment for electronic components. General specification: semiconductor optoelectronic and liquid crystal devices |
15/30265353 DC : 0 | BS EN 62271-1 ED 2 - HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 1: COMMON SPECIFICATIONS FOR ALTERNATING CURRENT SWITCHGEAR AND CONTROLGEAR |
BS EN 60747-15:2012 | Semiconductor devices. Discrete devices Isolated power semiconductor devices |
16/30336107 DC : 0 | BS EN 61850-7-4 AMD1 - COMMUNICATION NETWORKS AND SYSTEMS FOR POWER UTILITY AUTOMATION - PART 7-4: BASIC COMMUNICATION STRUCTURE - COMPATIBLE LOGICAL NODE CLASSES AND DATA OBJECT CLASSES |
IEC/IEEE 60076-57-129:2017 | Power transformers - Part 57-129: Transformers for HVDC applications |
15/30329267 DC : 0 | BS EN 60747-17 - SEMICONDUCTOR DEVICES - PART 17: MAGNETIC AND CAPACITIVE COUPLER FOR BASIC AND REINFORCED ISOLATION |
05/30133866 DC : DRAFT MAY 2005 | IEC 60076-6 - POWER TRANSFORMERS - PART 6: REACTORS |
04/30111589 DC : 0 | |
BIS IS/IEC 62271-200 : 2003 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 200: A.C. METAL-ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UPTO AND INCLUDING 52 KV |
CSA C88.1 : 1996 : R2005 | POWER TRANSFORMERS AND REACTOR BUSHINGS |
BS EN 60143-2:2013 | Series capacitors for power systems Protective equipment for series capacitor banks |
BS EN 50152-3-3:2016 | Railway applications. Fixed installations. Particular requirements for a.c. switchgear Measurement, control and protection devices for specific use in a.c. traction systems. Voltage transformers |
EN 60044-7:2000 | Instrument transformers - Part 7: Electronic voltage transformers |
CSA C60044-2 : 2007 | INSTRUMENT TRANSFORMERS - PART 2: INDUCTIVE VOLTAGE TRANSFORMERS |
BS EN 62271-100 : 2009 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 100: ALTERNATING-CURRENT CIRCUIT-BREAKERS (IEC 62271-100:2008) |
CSA C60044-8 :2007 | INSTRUMENT TRANSFORMERS - PART 8: ELECTRONIC CURRENT TRANSFORMERS |
CEI EN 60143-2 : 2014 | SERIES CAPACITORS FOR POWER SYSTEMS - PART 2: PROTECTIVE EQUIPMENT FOR SERIES CAPACITOR BANKS |
API STD 541 : 2014 | FORM-WOUND SQUIRREL CAGE INDUCTION MOTORS - 375 KW (500 HORSEPOWER) AND LARGER |
IEEE C57.13.5-2009 | IEEE Standard of Performance and Test Requirements for Instrument Transformers of a Nominal System Voltage of 115 kV and Above |
I.S. EN 60044-5:2004 | INSTRUMENT TRANSFORMERS - PART 5: CAPACITOR VOLTAGE TRANSFORMERS |
I.S. HD 597:2003 | COUPLING CAPACITORS AND CAPACITOR DIVIDERS |
I.S. EN 60060-2:2011 | HIGH-VOLTAGE TEST TECHNIQUES - PART 2: MEASURING SYSTEMS |
I.S. EN 61869-1:2009 | INSTRUMENT TRANSFORMERS - PART 1: GENERAL REQUIREMENTS |
CSA C22.2 No. 293.1 : 2017 | SKIN EFFECT TRACE HEATING OF PIPELINES, VESSELS, EQUIPMENT, AND STRUCTURES - GENERAL, TESTING, MARKING, AND DOCUMENTATION REQUIREMENTS |
I.S. EN 60265-2:1994 | HIGH-VOLTAGE SWITCHES - HIGH-VOLTAGE SWITCHES FOR RATED VOLTAGES OF 52 KV AND ABOVE |
BS EN 62271-1:2017 | High-voltage switchgear and controlgear Common specifications for alternating current switchgear and controlgear |
I.S. EN 61850-7-4:2010 | COMMUNICATION NETWORKS AND SYSTEMS FOR POWER UTILITY AUTOMATION - PART 7-4: BASIC COMMUNICATION STRUCTURE - COMPATIBLE LOGICAL NODE CLASSES AND DATA OBJECT CLASSES |
BS EN 62271-200:2012 | High-voltage switchgear and controlgear AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV |
EN 61057:2017 | Live working - Insulating aerial devices for mounting on a chassis |
PREN 50152-1 : DRAFT 2011 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 1: CIRCUIT-BREAKERS WITH NOMINAL VOLTAGE ABOVE 1 KV |
I.S. EN 61057:2017 | LIVE WORKING - INSULATING AERIAL DEVICES FOR MOUNTING ON A CHASSIS |
BS EN 62146-1 : 2014 | GRADING CAPACITORS FOR HIGH-VOLTAGE ALTERNATING CURRENT CIRCUIT-BREAKERS - PART 1: GENERAL (IEC 62146-1:2013) |
I.S. EN 2591-227:2015 | AEROSPACE SERIES - ELEMENTS OF ELECTRICAL AND OPTICAL CONNECTION - TEST METHODS - PART 227: PARTIAL DISCHARGES TEST |
I.S. EN 61010-031:2015 | SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL AND LABORATORY USE - PART 031: SAFETY REQUIREMENTS FOR HAND-HELD PROBE ASSEMBLIES FOR ELECTRICAL MEASUREMENT AND TEST |
I.S. EN 50152-3-2:2016 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR A.C. SWITCHGEAR - PART 3-2: MEASUREMENT, CONTROL AND PROTECTION DEVICES FOR SPECIFIC USE IN A.C. TRACTION SYSTEMS - SINGLE-PHASE CURRENT TRANSFORMERS |
PREN 50526-1 : DRAFT 2009 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SURGE ARRESTERS AND VOLTAGE LIMITING DEVICES - PART 1: SURGE ARRESTERS |
BIS IS/IEC 62271-1 : 2007 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 1: COMMON SPECIFICATIONS |
IEC TS 60034-18-41:2006 | Rotating electrical machines - Part 18-41: Qualification and type tests for Type I electrical insulation systems used in rotating electrical machines fed from voltage converters |
NF EN 50207 : 2004 | RAILWAY APPLICATIONS - ELECTRONIC POWER CONVERTERS FOR ROLLING STOCK |
EN 60137:2017 | Insulated bushings for alternating voltages above 1 000 V |
ISO 20958:2013 | Condition monitoring and diagnostics of machine systems — Electrical signature analysis of three-phase induction motors |
IEC 62501:2009+AMD1:2014+AMD2:2017 CSV | Voltage sourced converter (VSC) valves for high-voltage direct current (HVDC) power transmission - Electrical testing |
CEI EN 61850-7-4 : 2010 | COMMUNICATION NETWORKS AND SYSTEMS FOR POWER UTILITY AUTOMATION - PART 7-4: BASIC COMMUNICATION STRUCTURE - COMPATIBLE LOGICAL NODE CLASSES AND DATA OBJECT CLASSES |
EN 62271-200:2012/AC:2015 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 200: AC METAL-ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV (IEC 62271-200:2011) |
IEC TS 61934:2011 | Electrical insulating materials and systems - Electrical measurement of partial discharges (PD) under short rise time and repetitive voltage impulses |
I.S. EN 62199:2004 | BUSHINGS FOR D.C. APPLICATION |
IEC PAS 60747-17:2011 | Semiconductor devices - Discrete devices - Part 17: Magnetic and capacitive coupler for basic and reinforced isolation |
IEC 62068-1:2003 | Electrical insulation systems - Electrical stresses produced by repetitive impulses - Part 1: General method of evaluation of electrical endurance |
I.S. EN 61180-1:1995 | HIGH-VOLTAGE TEST TECHNIQUES FOR LOW-VOLTAGE EQUIPMENT - PART 1: DEFINITIONS, TEST AND PROCEDURE REQUIREMENTS |
IEC 60747-5-4:2006 | Semiconductor devices - Discrete devices - Part 5-4: Optoelectronic devices - Semiconductor lasers |
IEC TR 61294:1993 | Insulating liquids - Determination of the partial discharge inception voltage (PDIV) - Test procedure |
I.S. EN 60700-1:2015 | THYRISTOR VALVES FOR HIGH VOLTAGE DIRECT CURRENT (HVDC) POWER TRANSMISSION - PART 1: ELECTRICAL TESTING |
IEC 60076-3:2013+AMD1:2018 CSV | POWER TRANSFORMERS - PART 3: INSULATION LEVELS, DIELECTRIC TESTS AND EXTERNAL CLEARANCES IN AIR |
IEC 60343:1991 | Recommended test methods for determining the relative resistance of insulating materials to breakdown by surface discharges |
IEC 61378-2:2001 | Convertor transformers - Part 2: Transformers for HVDC applications |
EN 62823:2015 | Thyristor valves for thyristor controlled series capacitors (TCSC) - Electrical testing |
IEC 60143-4:2010 | Series capacitors for power systems - Part 4: Thyristor controlled series capacitors |
IEC 60076-13:2006 | Power transformers - Part 13: Self-protected liquid-filled transformers |
UNE-EN 50152-3-2:2016 | Railway applications - Fixed installations - Particular requirements for a.c. switchgear - Part 3-2: Measurement, control and protection devices for specific use in a.c. traction systems - Current transformers |
UNE-EN 60885-3:2015 | Electrical test methods for electric cables - Part 3: Test methods for partial discharge measurements on lengths of extruded power cables |
IEC 60044-8:2002 | Instrument transformers - Part 8: Electronic current transformers |
EN 61850-7-4:2010 | Communication networks and systems for power utility automation - Part 7-4: Basic communication structure - Compatible logical node classes and data object classes |
IEC 60044-5:2004 | Instrument transformers - Part 5: Capacitor voltage transformers |
UNE-EN 61869-1:2010 | Instrument transformers -- Part 1: General requirements |
EN 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
UL 61010-031:2ED 2017-01-27 | Standard for Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use - Part 031: Safety Requirements for Hand-Held and Hand-Manipulated Probe Assemblies for Electrical Test and Measurement |
EN 62271-104:2015 | High-voltage switchgear and controlgear - Part 104: Alternating current switches for rated voltages higher than 52 kV |
EN 61007:1997 | Transformers and inductors for use in electronic and telecommunication equipment - Measuring methods and test procedures |
UNI EN 3197 : 2012 | AEROSPACE SERIES - DESIGN AND INSTALLATION OF AIRCRAFT ELECTRICAL AND OPTICAL INTERCONNECTION SYSTEMS |
BS 223:1985 | Specification for bushings for alternating voltages above 1000 V |
CEI EN 61442 : 2006 | TEST METHODS FOR ACCESSORIES FOR POWER CABLES WITH RATED VOLTAGES FROM 6 KV (U[M] = 7,2 KV) UP TO 36 KV (U[M] = 42 KV) |
BS EN 60060-1:2010 | High-voltage test techniques General definitions and test requirements |
11/30242675 DC : 0 | BS EN 60099-4 F2 - SURGE ARRESTERS - PART 4: METAL-OXIDE SURGE ARRESTERS WITHOUT GAPS FOR A.C. SYSTEMS |
I.S. EN 60076-3:2013 | POWER TRANSFORMERS - PART 3: INSULATION LEVELS, DIELECTRIC TESTS AND EXTERNAL CLEARANCES IN AIR |
DIN VDE 0302-4 : 1988 | INSULATION SYSTEMS OF ELECTRICAL EQUIPMENT; ELECTRICAL ENDURANCE; GENERAL CONSIDERATIONS, EVALUATION PROCEDURES |
15/30314792 DC : 0 | BS EN 50152-3-2 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR A.C. SWITCHGEAR - PART 3-2: MEASUREMENT, CONTROL AND PROTECTION DEVICES FOR SPECIFIC USE IN A.C. TRACTION SYSTEMS - SINGLE-PHASE CURRENT TRANSFORMERS |
BS EN 60076-11:2004 | Power transformers Dry-type transformers |
CEI EN 60044-8 : 2004 | INSTRUMENT TRANSFORMERS - PART 8: ELECTRONIC CURRENT TRASFORMERS |
DIN IEC 60060-1 : 1994 | HIGH VOLTAGE TEST TECHNIQUES - GENERAL SPECIFICATIONS AND TEST REQUIREMENTS |
BIS IS/IEC 60044-1 : 2003 | INSTRUMENT TRANSFORMERS - PART 1: CURRENT TRANSFORMERS |
BS EN 60700-1:2015 | Thyristor valves for high voltage direct current (HVDC) power transmission Electrical testing |
11/30244390 DC : 0 | BS EN 61010-031 ED.2 - SAFETY REQUIREMENTS FOR HAND-HELD PROBE ASSEMBLIES FOR ELECTRICAL MEASUREMENT AND TEST |
CEI EN 60747-5-3 : 2002 | DISCRETE SEMICONDUCTOR DEVICES AND INTEGRATED CIRCUITS - PART 5-3: OPTOELECTRONIC DEVICES - MEASURING METHODS |
PD IEC/TS 60034-27-2:2012 | Rotating electrical machines On-line partial discharge measurements on the stator winding insulation of rotating electrical machines |
BS EN 60044-7:2000 | Instrument transformers Electronic voltage transformers |
10/30232718 DC : 0 | BS EN 60076-3 - POWER TRANSFORMERS - PART 3: INSULATION LEVELS, DIELECTRIC TESTS AND EXTERNAL CLEARANCES IN AIR |
BS EN 60747-5-3:2001 | Discrete semiconductor devices and integrated circuits. Optoelectronic devices Measuring methods |
DIN IEC 60885-3 : 2000 | ELECTRICAL TEST METHODS FOR ELECTRIC CABLES - PART 3: TEST METHODS FOR PARTIAL DISCHARGE MEASUREMENTS ON LENGTHS OF EXTRUDED POWER CABLES |
BS EN 62271-104:2015 | High-voltage switchgear and controlgear Alternating current switches for rated voltages higher than 52 kV |
BS EN 61007:1997 | Transformers and inductors for use in electronic and telecommunication equipment. Measuring methods and test procedures |
10/30238620 DC : 0 | BS EN 60034-18-41 TS ED - ROTATING ELECTRICAL MACHINES - PART 18-41: QUALIFICATION AND QUALITY CONTROL TESTS FOR PARTIAL DISCHARGE FREE (TYPE 1) ELECTRICAL INSULATION SYSTEMS USED IN ROTATING ELECTRICAL MACHINES FED FROM VOLTAGE CONVERTERS |
UNE-IEC/TS 62478:2017 | High voltage test techniques - Measurement of partial discharges by electromagnetic and acoustic methods |
BS EN 60505:2011 | Evaluation and qualification of electrical insulation systems |
08/30183914 DC : DRAFT JUNE 2008 | BS EN 60358-1 - COUPLING CAPACITORS AND CAPACITOR DIVIDERS - PART 1: COMMON CLAUSES |
EN IEC/IEEE 65700 : 2018 | BUSHINGS FOR DC APPLICATION (IEC/IEEE 65700-19-03:2014) |
UNE-EN 60076-16:2012 | Power transformers - Part 16: Transformers for wind turbines applications |
BS EN 60076-1:2011 | Power transformers General |
BS EN 60726:2003 | Dry-type power transformers |
CEI EN 60512-4-2 : 2003 | CONNECTORS FOR ELECTRONIC EQUIPMENT - TESTS AND MEASUREMENTS - PART 4-2: VOLTAGE STRESS TESTS TEST 4B: PARTIAL DISCHARGE |
BS EN 60099-9:2014 | Surge arresters Metal-oxide surge arresters without gaps for HVDC converter stations |
CEI UNI EN 45510-2-5 : 2006 | GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-5: ELECTRICAL EQUIPMENT - MOTORS |
BS EN 61057:1994 | Aerial devices with insulating boom used for live working exceeding 1 kV a.c. |
03/100549 DC : DRAFT APR 2003 | IEC 60664-4 ED. 2 - INSULATION COORDINATION FOR EQUIPMENT WITHIN LOW-VOLTAGE SYSTEMS - PART 4: CONSIDERATION OF HIGH-FREQUENCY VOLTAGE STRESS WITH RESPECT TO INSULATION COORDINATION OF EQUIPMENT WITHIN LOW-VOLTAGE SYSTEMS |
07/30168572 DC : 0 | BS IEC 61010-1 - SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL, AND LABORATORY USE - PART 1: GENERAL REQUIREMENTS |
11/30257861 DC : 0 | BS EN 60885-3 - ELECTRICAL TEST METHODS FOR ELECTRIC CABLES - PART 3: TEST METHODS FOR PARTIAL DISCHARGE MEASUREMENTS ON LENGTHS OF EXTRUDED POWER CABLES |
00/201882 DC : DRAFT APR 2000 | BS EN 60298 - A.C. METAL-ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV |
DIN EN 61180-1 : 1995 | HIGH-VOLTAGE TEST TECHNIQUES FOR LOW-VOLTAGE EQUIPMENT - PART 1: DEFINITIONS, TEST AND PROCEDURE REQUIREMENTS |
16/30318517 DC : 0 | BS EN 60137 ED. 7.0 - INSULATED BUSHINGS FOR ALTERNATING VOLTAGES ABOVE 1000 V |
BS IEC 60747-5.3 : 97 AMD 13434 | DISCRETE SEMICONDUCTOR DEVICES AND INTEGRATED CIRCUITS - OPTOELECTRONIC DEVICES - MEASURING METHODS |
11/30235283 DC : 0 | BS EN 50152-2 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 2: DISCONNECTORS, EARTHING SWITCHES AND SWITCHES WITH NOMINAL VOLTAGE ABOVE 1 KV |
NF EN 60660 : 2000 | INSULATORS - TESTS ON INDOOR POST INSULATORS OF ORGANIC MATERIAL FOR SYSTEMS WITH NOMINAL VOLTAGES GREATER THAN 1 KV UP TO BUT NON INCLUDING 300 KV |
VDE 0414-1 : 2001 | INSTRUMENT TRANSFORMERS - PART 1: CURRENT TRANSFORMERS |
CSA C60044-7 : 2007 : R2011 | INSTRUMENT TRANSFORMERS - PART 7: ELECTRONIC VOLTAGE TRANSFORMERS |
UNE-EN 50152-1:2013 | Railway applications - Fixed installations - Particular requirements for alternating current switchgear - Part 1: Circuit-breakers with nominal voltage above 1 kV |
UNE-EN 62271-104:2015 | High-voltage switchgear and controlgear - Part 104: Alternating current switches for rated voltages higher than 52 kV |
UNI CEI EN 45510-2-7 : 2011 | GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-7: ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR |
CSA C60044-7 : 2007 | INSTRUMENT TRANSFORMERS - PART 7: ELECTRONIC VOLTAGE TRANSFORMERS |
CSA C60044-1 : 2007 : R2011 | INSTRUMENT TRANSFORMERS - PART 1: CURRENT TRANSFORMERS |
UNE-EN 60060-2:2012 | High-voltage test techniques -- Part 2: Measuring systems. |
CSA C60044-1 : 2007 | INSTRUMENT TRANSFORMERS - PART 1: CURRENT TRANSFORMERS |
I.S. EN 62501:2009 | VOLTAGE SOURCED CONVERTER (VSC) VALVES FOR HIGH-VOLTAGE DIRECT CURENT (HVDC) POWER TRANSMISSION - ELECTRICAL TESTING |
CLC/TS 60034-18-34:2004 | Rotating electrical machines - Part 18-34: Functional evaluation of insulation systems - Test procedures for form-wound windings - Evaluation of thermomechanical endurance of insulation systems |
EN 62501:2009/A2:2017 | VOLTAGE SOURCED CONVERTER (VSC) VALVES FOR HIGH-VOLTAGE DIRECT CURRENT (HVDC) POWER TRANSMISSION - ELECTRICAL TESTING (IEC 62501:2009/A2:2017) |
API 546 : 2008 | BRUSHLESS SYNCHRONOUS MACHINES - 500 KVA AND LARGER |
I.S. EN 62823:2015 | THYRISTOR VALVES FOR THYRISTOR CONTROLLED SERIES CAPACITORS (TCSC) - ELECTRICAL TESTING |
CEI EN 60060-1 : 2015 | HIGH-VOLTAGE TEST TECHNIQUES - PART 1: GENERAL DEFINITIONS AND TEST REQUIREMENTS |
I.S. EN 62068-1:2003 | ELECTRICAL INSULATION SYSTEMS - ELECTRICAL STRESSES PRODUCED BY REPETITIVE IMPULSES - PART 1: GENERAL METHOD OF EVALUATION OF ELECTRICAL ENDURANCE |
IEEE C37.74-2014 | IEEE Standard Requirements for Subsurface, Vault, and Padmounted Load-Interrupter Switchgear and Fused Load-Interrupter Switchgear for Alternating Current Systems up to 38 kV |
I.S. EN 50152-1:2012 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 1: CIRCUIT-BREAKERS WITH NOMINAL VOLTAGE ABOVE 1 KV |
EN 62271-100 : 2009 AMD 2/COR 18 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 100: ALTERNATING-CURRENT CIRCUIT-BREAKERS (IEC 62271-100:2008/A2:2017/COR1:2018) |
IEEE C57.124 : 1991 | RECOMMENDED PRACTICE FOR THE DETECTION OF PARTIAL DISCHARGE AND THE MEASUREMENT OF APPARENT CHARGE IN DRY-TYPE TRANSFORMERS |
I.S. EN 50299-2:2014 | OIL-IMMERSED CABLE CONNECTION ASSEMBLIES FOR TRANSFORMERS AND REACTORS HAVING HIGHEST VOLTAGE FOR EQUIPMENT UM FROM 72,5 KV TO 550 KV - PART 2: DRY-TYPE CABLE TERMINATIONS |
I.S. EN 60099-8:2011 | SURGE ARRESTERS - PART 8: METAL-OXIDE SURGE ARRESTERS WITH EXTERNAL SERIES GAP (EGLA) FOR OVERHEAD TRANSMISSION AND DISTRIBUTION LINES OF A.C. SYSTEMS ABOVE 1 KV |
I.S. EN 50526-1:2012 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SURGE ARRESTERS AND VOLTAGE LIMITING DEVICES - PART 1: SURGE ARRESTERS |
ISO 18095:2018 | Condition monitoring and diagnostics of power transformers |
I.S. EN 62271-104:2015 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 104: ALTERNATING CURRENT SWITCHES FOR RATED VOLTAGES HIGHER THAN 52 KV |
API STD 17F : 2017 | SUBSEA PRODUCTION CONTROL SYSTEMS |
CEI EN 60505 : 2012 | EVALUATION AND QUALIFICATION OF ELECTRICAL INSULATION SYSTEMS |
CEI EN 60076-1 : 2015 | POWER TRANSFORMERS - PART 1: GENERAL |
VDE 0441-3 : 2000-12 | INSULATORS - TESTS ON INDOOR POST INSULATORS OF ORGANIC MATERIAL FOR SYSTEMS WITH NOMINAL VOLTAGES GREATER THAN 1 KV UP TO BUT NOT INCLUDING 300 KV |
PREN 50152-2 : DRAFT 2011 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 2: DISCONNECTORS, EARTHING SWITCHES AND SWITCHES WITH NOMINAL VOLTAGE ABOVE 1 KV |
CEI EN 60076-6 : 2015 | POWER TRANSFORMERS - PART 6: REACTORS |
I.S. EN 50152-2:2012 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 2: DISCONNECTORS, EARTHING SWITCHES AND SWITCHES WITH NOMINAL VOLTAGE ABOVE 1 KV |
CEI EN 50152-2 : 2013 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 2: DISCONNECTORS, EARTHING SWITCHES AND SWITCHES WITH NOMINAL VOLTAGE ABOVE 1 KV |
IEC 62848-1:2016 | Railway applications - DC surge arresters and voltage limiting devices - Part 1: Metal-oxide surge arresters without gaps |
I.S. EN 60076-6:2008 | POWER TRANSFORMERS - PART 6: REACTORS |
I.S. EN 60060-1:2010 | HIGH-VOLTAGE TEST TECHNIQUES - PART 1: GENERAL DEFINITIONS AND TEST REQUIREMENTS |
IEC TS 60034-27:2006 | Rotating electrical machines - Part 27: Off-line partial discharge measurements on the stator winding insulation of rotating electrical machines |
IEC 61057:2017 | Live working - Insulating aerial devices for mounting on a chassis |
I.S. EN 60343:1993 | RECOMMENDED TEST METHODS FOR DETERMINING THE RELATIVE RESISTANCE OF INSULATING MATERIALS TO BREAKDOWN BY SURFACE DISCHARGES |
I.S. EN 60664-1:2007 | INSULATION COORDINATION FOR EQUIPMENT WITHIN LOW-VOLTAGE SYSTEMS - PART 1: PRINCIPLES, REQUIREMENTS AND TESTS |
IEC 60034-27-1:2017 | Rotating electrical machines - Part 27-1: Off-line partial discharge measurements on the winding insulation |
IEC 61007:1994 | Transformers and inductors for use in electronic and telecommunication equipment - Measuring methods and test procedures |
IEC 61850-7-4:2010 | Communication networks and systems for power utility automation - Part 7-4: Basic communication structure - Compatible logical node classes and data object classes |
EN 60358-1:2012 | COUPLING CAPACITORS AND CAPACITOR DIVIDERS - PART 1: GENERAL RULES (IEC 60358-1:2012) |
IEC 61180-1:1992 | High-voltage test techniques for low voltage equipment - Part 1: Definitions, test and procedure requirements |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 60747-15:2010 | Semiconductor devices - Discrete devices - Part 15: Isolated power semiconductor devices |
IEC 62271-203:2011 | High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV |
IEC 60700-1:2015 | Thyristor valves for high voltage direct current (HVDC) power transmission - Part 1: Electrical testing |
IEC 60747-5-5:2007+AMD1:2013 CSV | Semiconductor devices - Discrete devices - Part 5-5: Optoelectronic devices - Photocouplers |
IEC 62068:2013 | Electrical insulating materials and systems - General method of evaluation of electrical endurance under repetitive voltage impulses |
IEC 61442:2005 | Test methods for accessories for power cables with rated voltages from 6 kV (Um = 7,2 kV) up to 30 kV (Um = 36 kV) |
UNE-EN 60076-1:2013 | Power transformers - Part 1: General |
IEC 62271-204:2011 | High-voltage switchgear and controlgear - Part 204: Rigid gas-insulated transmission lines for rated voltage above 52 kV |
UNE-EN 62271-201:2015 | High-voltage switchgear and controlgear - Part 201: AC solid-insulation enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV |
IEC 60505:2011 | Evaluation and qualification of electrical insulation systems |
UNE-EN 50152-3-3:2016 | Railway applications - Fixed installations - Particular requirements for a.c. switchgear - Part 3-3: Measurement, control and protection devices for specific use in a.c. traction systems - Voltage transformers |
IEC 60099-9:2014 | Surge arresters - Part 9: Metal-oxide surge arresters without gaps for HVDC converter stations |
IEC 61954:2011+AMD1:2013+AMD2:2017 CSV | Static var compensators (SVC) - Testing of thyristor valves |
IEC 60076-6:2007 | Power transformers - Part 6: Reactors |
IEC 60099-4:2014 | Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems |
IEC 60885-3:2015 RLV | Electrical test methods for electric cables - Part 3: Test methods for partial discharge measurements on lengths of extruded power cables |
IEC 60358-1:2012 | Coupling capacitors and capacitor dividers - Part 1: General rules |
IEC 60076-1:2011 | Power transformers - Part 1: General |
IEC 60143-2:2012 | Series capacitors for power systems - Part 2: Protective equipment for series capacitor banks |
IEC 62199:2004 | Bushings for d.c. application |
IEC 62271-104:2015 | High-voltage switchgear and controlgear - Part 104: Alternating current switches for rated voltages higher than 52 kV |
IEC 61287-1:2014 | Railway applications - Power converters installed on board rolling stock - Part 1: Characteristics and test methods |
IEC 62146-1:2013+AMD1:2016 CSV | Grading capacitors for high-voltage alternating current circuit-breakers - Part 1: General |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 60310:2016 | Railway applications - Traction transformers and inductors on board rolling stock |
IEC 60214-1:2014 | Tap-changers - Part 1: Performance requirements and test methods |
BS EN 61204-7:2006 | Live working. Conductive clothing Safety requirements |
IEC 60044-7:1999 | Instrument transformers - Part 7: Electronic voltage transformers |
EN 62271-204:2011 | High-voltage switchgear and controlgear - Part 204: Rigid gas-insulated transmission lines for rated voltage above 52 kV |
EN 60076-16:2011 | Power transformers - Part 16: Transformers for wind turbines applications |
EN 3197:2010 | Aerospace series - Design and installation of aircraft electrical and optical interconnection systems |
EN 45510-2-5:2002 | Guide for procurement of power station equipment - Part 2-5: Electrical equipment - Motors |
EN 45510-2-7:2002 | Guide for procurement of power station equipment - Part 2-7: Electrical equipment - Switchgear and controlgear |
EN 2591-227:2015 | Aerospace series - Elements of electrical and optical connection - Test methods - Part 227: Partial discharges test |
UNE-EN 50526-1:2012 | Railway applications - Fixed installations - D.C. surge arresters and voltage limiting devices - Part 1: Surge arresters |
04/30108943 DC : 0 | |
IEEE 400.4-2015 | IEEE Guide for Field Testing of Shielded Power Cable Systems Rated 5 kV and Above with Damped Alternating Current (DAC) Voltage |
UNE-EN 60060-1:2012 | High-voltage test techniques - Part 1: General definitions and test requirements |
CEI EN 60076-13 : 2007 | POWER TRANSFORMERS - PART 13: SELF PROTECTED LIQUID FILLED TRANSFORMERS |
DD IEC/PAS 60747-17:2011 | Semiconductor devices. Discrete devices Magnetic and capacitive coupler for basic and reinforced isolation |
11/30258048 DC : 0 | BS EN 62068 - ELECTRICAL INSULATING MATERIALS AND SYSTEMS - GENERAL METHOD OF EVALUATION OF ELECTRICAL ENDURANCE UNDER REPETITIVE VOLTAGE IMPULSES |
CLC/TS 60034-27:2011 | Rotating electrical machines - Part 27: Off-line partial discharge measurements on the stator winding insulation of rotating electrical machines |
S.R. CLC/TS 60034-27:2011 | ROTATING ELECTRICAL MACHINES - PART 27: OFF-LINE PARTIAL DISCHARGE MEASUREMENTS ON THE STATOR WINDING INSULATION OF ROTATING ELECTRICAL MACHINES |
BS EN 62501 : 2009 | VOLTAGE SOURCED CONVERTER (VSC) VALVES FOR HIGH-VOLTAGE DIRECT CURRENT (HVDC) POWER TRANSMISSION - ELECTRICAL TESTING |
CEI EN 60343 : 1997 | RECCOMMENDED TEST METHODS FOR DETERMINING THE RELATIVE RESISTANCE OF INSULATING MATERIALS TO BREAKDOWN BY SURFACE DISCHARGES |
CEI EN 62271-203 : 2013 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 203: GAS-INSULATED METAL-ENCLOSED SWITCHGEAR FOR RATED VOLTAGES ABOVE 52 KV |
PD IEC/TS 62478:2016 | High voltage test techniques. Measurement of partial discharges by electromagnetic and acoustic methods |
EN 61954:2011/A2:2017 | STATIC VAR COMPENSATORS (SVC) - TESTING OF THYRISTOR VALVES (IEC 61954:2011/A2:2017) |
NF EN 62146-1 : 2014 AMD 1 2016 | GRADING CAPACITORS FOR HIGH-VOLTAGE ALTERNATING CURRENT CIRCUIT-BREAKERS - PART 1: GENERAL |
BS EN 62823:2015 | Thyristor valves for thyristor controlled series capacitors (TCSC). Electrical testing |
BS EN 60298:1996 | A.C. metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV |
11/30245197 DC : 0 | BS EN 60143-2 - SERIES CAPACITORS FOR POWER SYSTEMS - PART 2: PROTECTIVE EQUIPMENTS FOR SERIES CAPACITOR BANKS |
12/30251830 DC : 0 | BS EN 62501:2009+A1 - VOLTAGE SOURCED CONVERTER (VSC) VALVES FOR HIGH-VOLTAGE DIRECT CURRENT (HVDC) POWER TRANSMISSION - ELECTRICAL TESTING |
IEC TS 60034-27-2:2012 | Rotating electrical machines - Part 27-2: On-line partial discharge measurements on the stator winding insulation of rotating electrical machines |
DIN VDE 0884 : 1987 | OPTOCOUPLER FOR PROTECTIVE SEPARATION AGAINST ELECTRIC SHOCK; REQUIREMENTS, TEST |
BS EN 60694:1997 | Common specifications for high-voltage switchgear and controlgear standards |
05/30128254 DC : DRAFT JAN 2005 | IEC 60034-27 - ROTATING ELECTRICAL MACHINES - PART 27: PARTIAL DISCHARGE OFF-LINE MEASUREMENTS ON THE STATOR WINDING INSULATION OF ROTATING MACHINERY |
BS EN 60143-1:2015 | Series capacitors for power systems General |
I.S. EN 62271-204:2011 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 204: RIGID GAS-INSULATED TRANSMISSION LINES FOR RATED VOLTAGE ABOVE 52 KV (IEC 62271-204:2011 (EQV)) |
BS EN 62271-201:2014 | High-voltage switchgear and controlgear AC solid-insulation enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV |
17/30368308 DC : 0 | BS EN 62271-109 - HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 109: ALTERNATING-CURRENT SERIES CAPACITOR BY-PASS SWITCHES |
BS EN 61378-2:2001 | Convertor transformers Transformers for HVDC applications |
BS ISO 20958:2013 | Condition monitoring and diagnostics of machine systems. Electrical signature analysis of three-phase induction motors |
BS EN 60664-4:2006 | Insulation coordination for equipment within low-voltage systems Consideration of high-frequency voltage stress |
DD CLC/TS 60034-27:2011 | Rotating electrical machines Off-line partial discharge measurements on the stator winding insulation of rotating electrical machines |
BS EN 62271-204:2011 | High-voltage switchgear and controlgear Rigid gas-insulated transmission lines for rated voltage above 52 kV |
16/30349321 DC : 0 | BS EN 60076-11 ED 2.0 - POWER TRANSFORMERS - PART 11: DRY-TYPE TRANSFORMERS |
IEC TS 62478:2016 | High voltage test techniques - Measurement of partial discharges by electromagnetic and acoustic methods |
98/203654 DC : DRAFT JULY 1998 | |
94/712993 DC : DRAFT NOV 1994 | PREN 45511 - GUIDE FOR PROCUREMENT - ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR |
BS EN 60885-3:2015 | Electrical test methods for electric cables Test methods for partial discharge measurements on lengths of extruded power cables |
I.S. EN IEC 60099-8:2018 | SURGE ARRESTERS - PART 8: METAL-OXIDE SURGE ARRESTERS WITH EXTERNAL SERIES GAP (EGLA) FOR OVERHEAD TRANSMISSION AND DISTRIBUTION LINES OF A.C. SYSTEMS ABOVE 1 KV |
09/30194359 DC : 0 | BS EN 60034-18-34 - ROTATING ELECTRICAL MACHINES - PART 18-34: FUNCTIONAL EVALUATION OF INSULATION SYSTEMS - TEST PROCEDURES FOR FORM-WOUND WINDINGS - EVALUATION OF THERMOMECHANICAL ENDURANCE OF INSULATION SYSTEMS |
NF EN 60099-8 : 2011 | SURGE ARRESTERS - PART 8: METAL-OXIDE SURGE ARRESTERS WITH EXTERNAL SERIES GAP (EGLA) FOR OVERHEAD TRANSMISSION AND DISTRIBUTION LINES OF A.C. SYSTEMS ABOVE 1 KV |
03/311404 DC : 0 | IEC 61010-1 ED.3 - SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL, AND LABORATORY USE - PART 1: GENERAL REQUIREMENTS |
04/30117440 DC : DRAFT JUL 2004 | IEC 60076-13. ED.1 - POWER TRANSFORMERS - PART 13: SELF-PROTECTED LIQUID FILLED TRANSFORMERS |
CSA C88.1 : 1996 : R2011 | POWER TRANSFORMERS AND REACTOR BUSHINGS |
BS EN 61180-1:1995 | High-voltage test techniques for low-voltage equipment Definitions, test and procedure requirements |
I.S. EN 60310:2016 | RAILWAY APPLICATIONS - TRACTION TRANSFORMERS AND INDUCTORS ON BOARD ROLLING STOCK |
BS EN 50152-2:2012 | Railway applications. Fixed installations. Particular requirements for alternating current switchgear Disconnectors, earthing switches and switches with nominal voltage above 1 kV |
IEEE 45.6-2016 | IEEE Recommended Practice for Electrical Installations on Shipboard--Electrical Testing |
BS EN 60076-3 : 2013 | POWER TRANSFORMERS - PART 3: INSULATION LEVELS, DIELECTRIC TESTS AND EXTERNAL CLEARANCES IN AIR |
CEI EN 61869-1 : 2010 | INSTRUMENT TRANSFORMERS - PART 1: GENERAL REQUIREMENTS |
I.S. EN 60044-8:2002 | INSTRUMENT TRANSFORMERS - PART 8: ELECTRONIC CURRENT TRANSFORMERS |
NF EN 50482 : 2008 | INSTRUMENT TRANSFORMERS - THREE-PHASE INDUCTIVE VOLTAGE TRANSFORMERS HAVING U[M] UP TO 52 KV |
IEEE 1277-2010 | IEEE Standard General Requirements and Test Code for Dry-Type and Oil-Immersed Smoothing Reactors for DC Power Transmission |
IEEE 400.2-2013 REDLINE | IEEE Guide for Field Testing of Shielded Power Cable Systems Using Very Low Frequency (VLF)(less than 1 Hz) |
IEEE 1434-2014 | IEEE Guide for the Measurement of Partial Discharges in AC Electric Machinery |
IEEE C57.129-2007 REDLINE | IEEE Standard for General Requirements and Test Code for Oil-Immersed HVDC Converter Transformers |
I.S. EN 60099-9:2014 | SURGE ARRESTERS - PART 9: METAL-OXIDE SURGE ARRESTERS WITHOUT GAPS FOR HVDC CONVERTER STATIONS |
IEEE C57.143-2012 | IEEE Guide for Application for Monitoring Equipment to Liquid-Immersed Transformers and Components |
I.S. EN 60143-1:2015 | SERIES CAPACITORS FOR POWER SYSTEMS - PART 1: GENERAL |
IEEE C57.127-2007 | IEEE Guide for the Detection and Location of Acoustic Emissions from Partial Discharges in Oil-Immersed Power Transformers and Reactors |
IEEE C57.19.0:2005 | STANDARD REQUIREMENTS, TERMINOLOGY, AND TEST CODE FOR BUSHINGS FOR DC APPLICATIONS |
CEI EN 60099-9 : 2015 | SURGE ARRESTERS - PART 9: METAL-OXIDE SURGE ARRESTERS WITHOUT GAPS FOR HVDC CONVERTER STATIONS |
I.S. EN 60137:2017 | INSULATED BUSHINGS FOR ALTERNATING VOLTAGES ABOVE 1000 V |
BS EN 60099-4:2014 | Surge arresters Metal-oxide surge arresters without gaps for a.c. systems |
DIN EN 60343 : 1994 | RECOMMENDED TEST METHODS FOR DETERMINING THE RELATIVE RESISTANCE OF INSULATING MATERIALS TO BREAKDOWN BY SURFACE DISCHARGES TEST METHODS |
I.S. EN IEC/IEEE 65700:2018 | BUSHINGS FOR DC APPLICATION |
CEI EN 60137 : 2009 | INSULATED BUSHINGS FOR ALTERNATING VOLTAGES ABOVE 1000 V |
UNE-EN 60214-1:2015 | Tap-changers - Part 1: Performance requirements and test methods |
CSA C22.2 No. 1010.1 : 0 | SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL, AND LABORATORY USE - GENERAL REQUIREMENTS |
NF EN 61442 : 2005 | TEST METHODS FOR ACCESSORIES FOR POWER CABLES WITH RATED VOLTAGES FROM 6 KV (UM = 7,2 KV) UP TO 36 KV (UM = 42 KV) |
CEI EN 60099-8 : 2012 | SURGE ARRESTERS - PART 8: METAL-OXIDE SURGE ARRESTERS WITH EXTERNAL SERIES GAP (EGLA) FOR OVERHEAD TRANSMISSION AND DISTRIBUTION LINES OF A.C. SYSTEMS ABOVE 1 KV |
CEI EN 60060-2 : 2015 | HIGH-VOLTAGE TEST TECHNIQUES - PART 2: MEASURING SYSTEMS |
I.S. EN 62271-200:2012 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 200: A.C. METAL-ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV (IEC 62271-200:2011 (EQV)) |
IEC PAS 60044-5:2002 | Instrument transformers - Part 5: Capacitor voltage transformers |
I.S. EN 60214-1:2014 | TAP-CHANGERS - PART 1: PERFORMANCE REQUIREMENTS AND TEST METHODS |
I.S. EN 62271-203:2012 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 203: GAS-INSULATED METAL-ENCLOSED SWITCHGEAR FOR RATED VOLTAGES ABOVE 52 KV (IEC 62271-203:2011 (EQV)) |
I.S. EN 62271-1:2017 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 1: COMMON SPECIFICATIONS FOR ALTERNATING CURRENT SWITCHGEAR AND CONTROLGEAR |
I.S. EN 62271-100:2009 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 100: ALTERNATING-CURRENT CIRCUIT-BREAKERS |
IEC 62505-1:2016 | Railway applications - Fixed installations - Particular requirements for AC switchgear - Part 1: Circuit-breakers with nominal voltage above 1 kV |
I.S. EN 62271-201:2014 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 201: AC SOLID-INSULATION ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV |
IEC 61869-1:2007 | Instrument transformers - Part 1: General requirements |
EN 60747-5-5:2011/A1:2015 | SEMICONDUCTOR DEVICES - DISCRETE DEVICES - PART 5-5: OPTOELECTRONIC DEVICES - PHOTOCOUPLERS (IEC 60747-5-5:2007/A1:2013) |
IEEE/CSA 844.1/CSA C22.2 No.293.1-2017 | IEEE/CSA Standard for Skin Effect Trace Heating of Pipelines, Vessels, Equipment, and Structures - General, Testing, Marking, and Documentation Requirements |
IEC 60512-4-2:2002 | Connectors for electronic equipment - Tests and measurements - Part 4-2: Voltage stress tests - Test 4b: Partial discharge |
IEC 62271-201:2014 | High-voltage switchgear and controlgear - Part 201: AC solid-insulation enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV |
IEC 60076-16:2011 | Power transformers - Part 16: Transformers for wind turbine applications |
IEC 62271-100:2008+AMD1:2012+AMD2:2017 CSV | High-voltage switchgear and controlgear - Part 100: Alternating-current circuit-breakers |
IEC 62271-200:2011 | High-voltage switchgear and controlgear - Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV |
IEC 60044-2:1997+AMD1:2000+AMD2:2002 CSV | Instrument transformers - Part 2 : Inductive voltage transformers |
DIN VDE 0805 : 1990 AMD 1 1991 | SAFETY OF INFORMATION TECHNOLOGY EQUIPMENT INCLUDING ELECTRICAL BUSINESS EQUIPMENT |
EN 61287-1:2014/AC:2014 | RAILWAY APPLICATIONS - POWER CONVERTERS INSTALLED ON BOARD ROLLING STOCK - PART 1: CHARACTERISTICS AND TEST METHODS (IEC 61287-1:2014) |
EN 61180-1:1994 | High-voltage test techniques for low-voltage equipment - Part 1: Definitions, test and procedure requirements |
EN 61378-2:2001 | Convertor transformers - Part 2: Transformers for HVDC applications |
EN 60700-1:2015/AC:2017-02 | THYRISTOR VALVES FOR HIGH VOLTAGE DIRECT CURRENT (HVDC) POWER TRANSMISSION - PART 1: ELECTRICAL TESTING (IEC 60700-1:2015/COR1:2017) |
EN 60885-3:2015 | Electrical test methods for electric cables - Part 3: Test methods for partial discharge measurements on lengths of extruded power cables |
EN 50152-2:2012 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 2: DISCONNECTORS, EARTHING SWITCHES AND SWITCHES WITH NOMINAL VOLTAGE ABOVE 1 KV |
EN 60076-6:2008 | Power transformers - Part 6: Reactors |
EN 60044-1:1999/A2:2003 | INSTRUMENT TRANSFORMERS - PART 1: CURRENT TRANSFORMERS |
EN 62146-1:2014/A1:2016 | GRADING CAPACITORS FOR HIGH-VOLTAGE ALTERNATING CURRENT CIRCUIT-BREAKERS - PART 1: GENERAL (IEC 62146-1:2013/A1:2016) |
EN 61869-1:2009 | Instrument transformers - Part 1: General requirements |
EN 60076-13 : 2006 | POWER TRANSFORMERS - PART 13: SELF-PROTECTED LIQUID-FILLED TRANSFORMERS |
EN 50299-2:2014 | Oil-immersed cable connection assemblies for transformers and reactors having highest voltage for equipment Um from 72,5 kV to 550 kV - Part 2: Dry-type cable terminations |
EN 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
EN 60099-9:2014 | Surge arresters - Part 9: Metal-oxide surge arresters without gaps for HVDC converter stations |
EN 60143-4 : 2010 | SERIES CAPACITORS FOR POWER SYSTEMS - PART 4: THYRISTOR CONTROLLED SERIES CAPACITORS |
EN 62068-1:2003 | Electrical insulation systems - Electrical stresses produced by repetitive impulses - Part 1: General method of evaluation of electrical endurance |
EN 62271-203:2012 | High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV |
EN 60143-2:2013 | Series capacitors for power systems - Part 2: Protective equipment for series capacitor banks |
EN 50152-1 : 2012 AMD 1 2013 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 1: CIRCUIT-BREAKERS WITH NOMINAL VOLTAGE ABOVE 1 KV |
EN 60664-4:2006/corrigendum:2006 | INSULATION COORDINATION FOR EQUIPMENT WITHIN LOW-VOLTAGE SYSTEMS - PART 4: CONSIDERATION OF HIGH-FREQUENCY VOLTAGE STRESS |
EN 62068:2013 | Electrical insulating materials and systems - General method of evaluation of electrical endurance under repetitive voltage impulses |
EN 50526-1:2012 | Railway applications - Fixed installations - D.C. surge arresters and voltage limiting devices - Part 1: Surge arresters |
EN 60044-8:2002 | Instrument transformers - Part 8: Electronic current transformers |
EN 60214-1:2014 | Tap-changers - Part 1: Performance requirements and test methods |
EN 60076-1:2011 | POWER TRANSFORMERS - PART 1: GENERAL (IEC 60076-1:2011) |
EN 60044-2:1999/A2:2003 | INSTRUMENT TRANSFORMERS - PART 2: INDUCTIVE VOLTAGE TRANSFORMERS |
IEC 60099-8:2017 RLV | Surge arresters - Part 8: Metal-oxide surge arresters with external series gap (EGLA) for overhead transmission and distribution lines of a.c. systems above 1 kV |
EN 60512-4-2:2002 | Connectors for electronic equipment - Tests and measurements - Part 4-2: Voltage stress tests - Test 4b: Partial discharge |
EN 61010-031:2015 | Safety requirements for electrical equipment for measurement, control and laboratory use - Part 031: Safety requirements for hand-held probe assemblies for electrical measurement and test |
EN 60310:2016/AC:2018-03 | RAILWAY APPLICATIONS - TRACTION TRANSFORMERS AND INDUCTORS ON BOARD ROLLING STOCK (IEC 60310:2016/COR1:2018) |
EN 60076-3:2013/A1:2018 | POWER TRANSFORMERS - PART 3: INSULATION LEVELS, DIELECTRIC TESTS AND EXTERNAL CLEARANCES IN AIR (IEC 60076-3:2013/A1:2018) |
IEC 60060-2:2010 | High-voltage test techniques - Part 2: Measuring systems |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
CISPR 16-1:1999+AMD1:2002 CSV | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1: Radio disturbance and immunity measuring apparatus |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.